BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

302 related articles for article (PubMed ID: 36098029)

  • 21. Continuous glucose monitoring in pregnant women with type 1 diabetes (CONCEPTT): a multicentre international randomised controlled trial.
    Feig DS; Donovan LE; Corcoy R; Murphy KE; Amiel SA; Hunt KF; Asztalos E; Barrett JFR; Sanchez JJ; de Leiva A; Hod M; Jovanovic L; Keely E; McManus R; Hutton EK; Meek CL; Stewart ZA; Wysocki T; O'Brien R; Ruedy K; Kollman C; Tomlinson G; Murphy HR;
    Lancet; 2017 Nov; 390(10110):2347-2359. PubMed ID: 28923465
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparing effects of continuous glucose monitoring systems (CGMs) and self-monitoring of blood glucose (SMBG) amongst adults with type 2 diabetes mellitus: a systematic review protocol.
    Zheng M; Luo Y; Lin W; Khoja A; He Q; Yang S; Zhao X; Hu P
    Syst Rev; 2020 May; 9(1):120. PubMed ID: 32475343
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Positioning time in range in diabetes management.
    Advani A
    Diabetologia; 2020 Feb; 63(2):242-252. PubMed ID: 31701199
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Continuous glucose monitoring in adults with type 2 diabetes: a systematic review and meta-analysis.
    Jancev M; Vissers TACM; Visseren FLJ; van Bon AC; Serné EH; DeVries JH; de Valk HW; van Sloten TT
    Diabetologia; 2024 May; 67(5):798-810. PubMed ID: 38363342
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Glycaemia risk index uncovers distinct glycaemic variability patterns associated with remission status in type 1 diabetes.
    Zhong T; He B; Li X; Lei K; Tang R; Zhao B; Li X
    Diabetologia; 2024 Jan; 67(1):42-51. PubMed ID: 37889319
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Applications of continuous glucose monitoring across settings and populations: Report from the 23rd Hong Kong diabetes and cardiovascular risk factors-East meets west symposium.
    Oliver N; Chow E; Luk AOY; Murphy HR
    Diabet Med; 2023 May; 40(5):e15038. PubMed ID: 36617376
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Association Between Continuous Glucose Monitoring-Derived Time in Range, Other Core Metrics, and Albuminuria in Type 2 Diabetes.
    Yoo JH; Choi MS; Ahn J; Park SW; Kim Y; Hur KY; Jin SM; Kim G; Kim JH
    Diabetes Technol Ther; 2020 Oct; 22(10):768-776. PubMed ID: 32167394
    [No Abstract]   [Full Text] [Related]  

  • 28. Metabolic phenotypes explain the relationship between dysglycaemia and frailty in older people with type 2 diabetes.
    Abdelhafiz AH; Sinclair AJ
    J Diabetes Complications; 2022 Apr; 36(4):108144. PubMed ID: 35151546
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Relationships between time in range, glycemic variability including hypoglycemia and types of diabetes therapy in Japanese patients with type 2 diabetes mellitus: Hyogo Diabetes Hypoglycemia Cognition Complications study.
    Kuroda N; Kusunoki Y; Osugi K; Ohigashi M; Azuma D; Ikeda H; Makino S; Otsuka A; Tamada D; Watanabe N; Washio K; Tsunoda T; Matsuo T; Konishi K; Katsuno T; Koyama H;
    J Diabetes Investig; 2021 Feb; 12(2):244-253. PubMed ID: 32594655
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Application of medium-term metrics for assessing glucose homoeostasis: Usefulness, strengths and weaknesses.
    Monnier L; Colette C; Owens D
    Diabetes Metab; 2021 Mar; 47(2):101173. PubMed ID: 32561428
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Relationships between HbA1c and continuous glucose monitoring metrics of glycaemic control and glucose variability in a large cohort of children and adolescents with type 1 diabetes.
    Piona C; Marigliano M; Mozzillo E; Rosanio F; Zanfardino A; Iafusco D; Maltoni G; Zucchini S; Piccinno E; Delvecchio M; Maffeis C
    Diabetes Res Clin Pract; 2021 Jul; 177():108933. PubMed ID: 34216681
    [TBL] [Abstract][Full Text] [Related]  

  • 32. An Assessment of Clinical Continuous Glucose Monitoring Targets for Older and High-Risk People Living with Type 1 Diabetes.
    O'Neal DN; Cohen O; Vogrin S; Vigersky RA; Jenkins AJ;
    Diabetes Technol Ther; 2023 Feb; 25(2):108-115. PubMed ID: 36315189
    [No Abstract]   [Full Text] [Related]  

  • 33. (Ultra-)long-acting insulin analogues versus NPH insulin (human isophane insulin) for adults with type 2 diabetes mellitus.
    Semlitsch T; Engler J; Siebenhofer A; Jeitler K; Berghold A; Horvath K
    Cochrane Database Syst Rev; 2020 Nov; 11(11):CD005613. PubMed ID: 33166419
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Diabetes technology and treatments in the paediatric age group.
    Shalitin S; Peter Chase H
    Int J Clin Pract Suppl; 2011 Feb; (170):76-82. PubMed ID: 21323816
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Effectiveness of Continuous Glucose Monitoring in Older Adults with Type 2 Diabetes Treated with Basal Insulin.
    Bao S; Bailey R; Calhoun P; Beck RW
    Diabetes Technol Ther; 2022 May; 24(5):299-306. PubMed ID: 34939824
    [No Abstract]   [Full Text] [Related]  

  • 36. Continuous glucose monitoring metrics following sub-Tenon's injection of triamcinolone acetonide for diabetic macular edema.
    Sotani-Ogawa R; Kusuhara S; Hirota Y; Kim KW; Matsumiya W; Ogawa W; Nakamura M
    Graefes Arch Clin Exp Ophthalmol; 2024 Feb; 262(2):449-456. PubMed ID: 37864636
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Continuous glucose monitoring for patients with type 1 diabetes and impaired awareness of hypoglycaemia (IN CONTROL): a randomised, open-label, crossover trial.
    van Beers CA; DeVries JH; Kleijer SJ; Smits MM; Geelhoed-Duijvestijn PH; Kramer MH; Diamant M; Snoek FJ; Serné EH
    Lancet Diabetes Endocrinol; 2016 Nov; 4(11):893-902. PubMed ID: 27641781
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Continuous Glucose Monitoring Metrics in High-Risk Pregnant Women with Type 2 Diabetes.
    McLean A; Barr E; Tabuai G; Murphy HR; Maple-Brown L
    Diabetes Technol Ther; 2023 Dec; 25(12):836-844. PubMed ID: 37902969
    [No Abstract]   [Full Text] [Related]  

  • 39. Assessing non-adjunctive CGM safety at home and in new markets (ANSHIN).
    Chao C; Andrade SB; Bergford S; Calhoun P; Welsh JB; Walker TC;
    Endocrinol Diabetes Metab; 2023 May; 6(3):e414. PubMed ID: 36864014
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Associations between continuous glucose monitoring-derived metrics and arterial stiffness in Japanese patients with type 2 diabetes.
    Wakasugi S; Mita T; Katakami N; Okada Y; Yoshii H; Osonoi T; Kuribayashi N; Taneda Y; Kojima Y; Gosho M; Shimomura I; Watada H
    Cardiovasc Diabetol; 2021 Jan; 20(1):15. PubMed ID: 33413339
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 16.