These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 36102991)

  • 1. Serum metal ion levels following spinal deformity surgery: a case-control study of 182 individuals.
    Fell D; Diarbakerli E; Gerdhem P
    Eur Spine J; 2022 Nov; 31(11):3036-3041. PubMed ID: 36102991
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A systematic review of metal ion concentrations following instrumented spinal fusion.
    Siddiqi O; Urquhart JC; Rasoulinejad P
    Spine Deform; 2021 Jan; 9(1):13-40. PubMed ID: 32780305
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Are Serum Ion Levels Elevated in Pediatric Patients With Metal Implants?
    Mathew SE; Xie Y; Bagheri L; Claton LE; Chu L; Badreldin A; Abdel MP; van Wijnen AJ; Haft GF; Milbrandt TA; Larson AN
    J Pediatr Orthop; 2022 Mar; 42(3):162-168. PubMed ID: 34619722
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison between 4.0-mm stainless steel and 4.75-mm titanium alloy single-rod spinal instrumentation for anterior thoracoscopic scoliosis surgery.
    Yoon SH; Ugrinow VL; Upasani VV; Pawelek JB; Newton PO
    Spine (Phila Pa 1976); 2008 Sep; 33(20):2173-8. PubMed ID: 18794758
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Predictors of serum chromium levels after stainless steel posterior spinal instrumentation for adolescent idiopathic scoliosis.
    Rackham MD; Cundy TP; Antoniou G; Freeman BJ; Sutherland LM; Cundy PJ
    Spine (Phila Pa 1976); 2010 Apr; 35(9):975-82. PubMed ID: 20375769
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Positive security screening episodes of patients with spinal implants are influenced by detector type and not implant material.
    Arhewoh R; Kelly BA; Kelly MP; Buchowski JM; Gupta MC; Luhmann SJ
    Spine J; 2022 May; 22(5):738-746. PubMed ID: 34936885
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cobalt chromium sublaminar wires for spinal deformity surgery.
    Cluck MW; Skaggs DL
    Spine (Phila Pa 1976); 2006 Sep; 31(19):2209-12. PubMed ID: 16946655
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Chromium ion release from stainless steel pediatric scoliosis instrumentation.
    Cundy TP; Delaney CL; Rackham MD; Antoniou G; Oakley AP; Freeman BJ; Sutherland LM; Cundy PJ
    Spine (Phila Pa 1976); 2010 Apr; 35(9):967-74. PubMed ID: 20407339
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Metal ion release from bearing wear and corrosion with 28 mm and large-diameter metal-on-metal bearing articulations: a follow-up study.
    Vendittoli PA; Roy A; Mottard S; Girard J; Lusignan D; Lavigne M
    J Bone Joint Surg Br; 2010 Jan; 92(1):12-9. PubMed ID: 20044673
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Chromium Metal Ion Release During Instrumented Spinal Surgery in Children: The Effects of Electrosurgery.
    Cundy PJ; Antoniou G; Mascarhenas A; Freeman BJC; Cundy WJ
    Spine (Phila Pa 1976); 2020 Dec; 45(23):1619-1624. PubMed ID: 32890308
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern?
    Serhan H; Slivka M; Albert T; Kwak SD
    Spine J; 2004; 4(4):379-87. PubMed ID: 15246296
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Long-term systemic metal distribution in patients with stainless steel spinal instrumentation: a case-control study.
    Savarino L; Greggi T; Martikos K; Lolli F; Greco M; Baldini N
    J Spinal Disord Tech; 2015 Apr; 28(3):114-8. PubMed ID: 22907064
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A novel scoliosis instrumentation using special superelastic nickel-titanium shape memory rods: a biomechanical analysis using a calibrated computer model and data from a clinical trial.
    Wang X; Yeung K; Cheung JPY; Lau JY; Qi W; Cheung KM; Aubin CE
    Spine Deform; 2020 Jun; 8(3):369-379. PubMed ID: 32096138
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In vivo blood metal ion levels in patients after total shoulder arthroplasty.
    Reiner T; Bader N; Panzram B; Bülhoff M; Omlor G; Kretzer JP; Raiss P; Zeifang F
    J Shoulder Elbow Surg; 2019 Mar; 28(3):539-546. PubMed ID: 30518478
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Serum levels of nickel and chromium after instrumented posterior spinal arthrodesis.
    Kim YJ; Kassab F; Berven SH; Zurakowski D; Hresko MT; Emans JB; Kasser JR
    Spine (Phila Pa 1976); 2005 Apr; 30(8):923-6. PubMed ID: 15834337
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Metal levels in cemented total hip arthroplasty. A comparison of well-fixed and loose implants.
    Brien WW; Salvati EA; Betts F; Bullough P; Wright T; Rimnac C; Buly R; Garvin K
    Clin Orthop Relat Res; 1992 Mar; (276):66-74. PubMed ID: 1537176
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Metal ion levels in patients with stainless steel spinal instrumentation.
    McPhee IB; Swanson CE
    Spine (Phila Pa 1976); 2007 Aug; 32(18):1963-8. PubMed ID: 17700441
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Metal ion levels from well-functioning Birmingham Hip Resurfacings decline significantly at ten years.
    Van Der Straeten C; Van Quickenborne D; De Roest B; Calistri A; Victor J; De Smet K
    Bone Joint J; 2013 Oct; 95-B(10):1332-8. PubMed ID: 24078528
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of systemic metal diffusion after spinal pedicular fixation with titanium alloy and stainless steel system: a 36-month experimental study in sheep.
    Brayda-Bruno M; Fini M; Pierini G; Giavaresi G; Rocca M; Giardino R
    Int J Artif Organs; 2001 Jan; 24(1):41-9. PubMed ID: 11266042
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Metal ion levels in ceramic-on-ceramic THR with cobalt-chrome modular necks: analysis of cobalt and chromium serum levels in 23 healthy hip patients.
    Somers JF; Dedrye L; Goeminne S
    Hip Int; 2017 Feb; 27(1):21-25. PubMed ID: 27791242
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.