137 related articles for article (PubMed ID: 36116102)
1. Electro-immunosensor for ultra-sensitive determination of cardiac troponin I based on reduced graphene oxide and polytyramine.
Brussasco JG; Guedes PHG; Moço ACR; Moraes DD; Flauzino JMR; Silva HS; Silva AC; Silva JP; Madurro JM; Brito-Madurro AG
J Mol Recognit; 2023 Feb; 36(2):e2995. PubMed ID: 36116102
[TBL] [Abstract][Full Text] [Related]
2. Porous graphene oxide nanostructure as an excellent scaffold for label-free electrochemical biosensor: Detection of cardiac troponin I.
Kazemi SH; Ghodsi E; Abdollahi S; Nadri S
Mater Sci Eng C Mater Biol Appl; 2016 Dec; 69():447-52. PubMed ID: 27612734
[TBL] [Abstract][Full Text] [Related]
3. Nanocomposites of gold nanoparticles and graphene oxide towards an stable label-free electrochemical immunosensor for detection of cardiac marker troponin-I.
Liu G; Qi M; Zhang Y; Cao C; Goldys EM
Anal Chim Acta; 2016 Feb; 909():1-8. PubMed ID: 26851079
[TBL] [Abstract][Full Text] [Related]
4. Impedimetric cardiac biomarker determination in serum mediated by epoxy and hydroxyl of reduced graphene oxide on gold array microelectrodes.
Taniselass S; Arshad MKM; Gopinath SCB; Fathil MFM; Ibau C; Anbu P
Mikrochim Acta; 2021 Jul; 188(8):257. PubMed ID: 34268634
[TBL] [Abstract][Full Text] [Related]
5. Electrochemical immunosensor for determination of cardiac troponin I using two-dimensional metal-organic framework/Fe
Ahmadi A; Khoshfetrat SM; Mirzaeizadeh Z; Kabiri S; Rezaie J; Omidfar K
Talanta; 2022 Jan; 237():122911. PubMed ID: 34736648
[TBL] [Abstract][Full Text] [Related]
6. Electrochemical immunosensor for highly sensitive detection of cTnI via in-situ initiated ROP signal amplification strategy.
Cheng D; Zhou Z; Shang S; Wang H; Guan H; Yang H; Liu Y
Anal Chim Acta; 2022 Aug; 1219():340032. PubMed ID: 35715132
[TBL] [Abstract][Full Text] [Related]
7. Photoelectrochemical Determination of Cardiac Troponin I as a Biomarker of Myocardial Infarction Using a Bi
Monteiro TO; Neto AGDS; de Menezes AS; Damos FS; Luz RCS; Fatibello-Filho O
Biosensors (Basel); 2023 Mar; 13(3):. PubMed ID: 36979591
[TBL] [Abstract][Full Text] [Related]
8. Thionin functionalized signal amplification label derived dual-mode electrochemical immunoassay for sensitive detection of cardiac troponin I.
Lv H; Li Y; Zhang X; Li X; Xu Z; Chen L; Li D; Dong Y
Biosens Bioelectron; 2019 May; 133():72-78. PubMed ID: 30909015
[TBL] [Abstract][Full Text] [Related]
9. A sensitive ratiometric biosensor for determination cardiac troponin I of myocardial infarction markers based on N, Zn-GQDs.
Liu M; Jiang R; Zheng M; Li M; Yu Q; Zhu H; Guo H; Sun H
Talanta; 2022 Nov; 249():123577. PubMed ID: 35724555
[TBL] [Abstract][Full Text] [Related]
10. Electrochemical Immunosensor for Cardiac Troponin I Detection Based on Covalent Organic Framework and Enzyme-Catalyzed Signal Amplification.
Feng S; Yan M; Xue Y; Huang J; Yang X
Anal Chem; 2021 Oct; 93(40):13572-13579. PubMed ID: 34591449
[TBL] [Abstract][Full Text] [Related]
11. An electrochemical immunosensor for cardiac Troponin I using electrospun carboxylated multi-walled carbon nanotube-whiskered nanofibres.
Rezaei B; Shoushtari AM; Rabiee M; Uzun L; Mak WC; Turner APF
Talanta; 2018 May; 182():178-186. PubMed ID: 29501138
[TBL] [Abstract][Full Text] [Related]
12. Antibody coated conductive polymer for the electrochemical immunosensing of Human Cardiac Troponin I in blood plasma.
Gholami MD; O'Mullane AP; Sonar P; Ayoko GA; Izake EL
Anal Chim Acta; 2021 Nov; 1185():339082. PubMed ID: 34711328
[TBL] [Abstract][Full Text] [Related]
13. Electrochemiluminescence biosensor for cardiac troponin I with signal amplification based on a MoS
Wang B; Wang C; Li Y; Liu X; Wu D; Wei Q
Analyst; 2022 Oct; 147(21):4768-4776. PubMed ID: 36149312
[TBL] [Abstract][Full Text] [Related]
14. Reduced graphene oxide-gold nanoparticles-catalase-based dual signal amplification strategy in a spatial-resolved ratiometric electrochemiluminescence immunoassay.
Cao JT; Fu XL; Liu FR; Ren SW; Liu YM
Analyst; 2019 Dec; 145(1):91-96. PubMed ID: 31742265
[TBL] [Abstract][Full Text] [Related]
15. An electrochemical sandwich immunosensor for cardiac troponin I by using nitrogen/sulfur co-doped graphene oxide modified with Au@Ag nanocubes as amplifiers.
Lv H; Zhang X; Li Y; Ren Y; Zhang C; Wang P; Xu Z; Li X; Chen Z; Dong Y
Mikrochim Acta; 2019 Jun; 186(7):416. PubMed ID: 31187243
[TBL] [Abstract][Full Text] [Related]
16. Electrochemical immunosensor based on Au/Co-BDC/MoS
Zhao H; Du X; Dong H; Jin D; Tang F; Liu Q; Wang P; Chen L; Zhao P; Li Y
Biosens Bioelectron; 2021 Mar; 175():112883. PubMed ID: 33341318
[TBL] [Abstract][Full Text] [Related]
17. One step in-situ synthesis of amine functionalized graphene for immunosensing of cardiac marker cTnI.
Tuteja SK; Kukkar M; Suri CR; Paul AK; Deep A
Biosens Bioelectron; 2015 Apr; 66():129-35. PubMed ID: 25460893
[TBL] [Abstract][Full Text] [Related]
18. A novel fluorescent aptasensor for the highly sensitive and selective detection of cardiac troponin I based on a graphene oxide platform.
Liu D; Lu X; Yang Y; Zhai Y; Zhang J; Li L
Anal Bioanal Chem; 2018 Jul; 410(18):4285-4291. PubMed ID: 29725733
[TBL] [Abstract][Full Text] [Related]
19. Cardiovascular biomarker troponin I biosensor: Aptamer-gold-antibody hybrid on a metal oxide surface.
Hui H; Gopinath SCB; Ismail ZH; Chen Y; Pandian K; Velusamy P
Biotechnol Appl Biochem; 2023 Apr; 70(2):581-591. PubMed ID: 35765758
[TBL] [Abstract][Full Text] [Related]
20. Label-Free Immunosensor Based on Liquid Crystal and Gold Nanoparticles for Cardiac Troponin I Detection.
Zapp E; Brondani D; Silva TR; Girotto E; Gallardo H; Vieira IC
Biosensors (Basel); 2022 Dec; 12(12):. PubMed ID: 36551080
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]