These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 36127272)

  • 1. Early pacemaker insertion after aortic valve replacement with an Edwards Intuity sutureless valve.
    Mechulan A; Demoulin R; Dieuzaide P; Peret A; Vaillant A; Vicat J; Bouharaoua A; Leude-Vaillant E; Cornen A; Prevot S
    Arch Cardiovasc Dis; 2022 Oct; 115(10):490-495. PubMed ID: 36127272
    [TBL] [Abstract][Full Text] [Related]  

  • 2. New postoperative conduction abnormalities after the implantation of a rapid-deployment aortic valve prosthesis.
    Mogilansky C; Balan R; Deutsch C; Czesla M; Massoudy P
    Interact Cardiovasc Thorac Surg; 2019 Apr; 28(4):581-586. PubMed ID: 30412244
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Sutureless aortic valve replacement with Perceval bioprosthesis: are there predicting factors for postoperative pacemaker implantation?
    Vogt F; Pfeiffer S; Dell'Aquila AM; Fischlein T; Santarpino G
    Interact Cardiovasc Thorac Surg; 2016 Mar; 22(3):253-8. PubMed ID: 26614526
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of Conduction Disorders After Aortic Valve Replacement With Rapid Deployment Bioprostheses.
    DʼOnofrio A; Bagozzi L; Tessari C; Francescato A; Cibin G; Besola L; Pesce R; Toscano G; Gerosa G
    Innovations (Phila); 2018; 13(5):356-360. PubMed ID: 30394957
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Risk Factors for Postoperative Pacemaker Implantation After Rapid Deployment Aortic Valve Replacement: Results from the RADAR Registry.
    Gonzalez-Barbeito M; Arribas JM; Vazquez A; Carnero M; Sarralde JA; Cal-Purriños N; Cánovas SJ; Maroto L; Gutiérrez F; Hornero F; Bautista-Hernandez V
    Adv Ther; 2021 Apr; 38(4):1832-1842. PubMed ID: 33665760
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Permanent Pacemaker Implantation After Rapid Deployment Aortic Valve Replacement.
    Romano MA; Koeckert M; Mumtaz MA; Slachman FN; Patel HJ; Chitwood WR; Barnhart GR; Grossi EA;
    Ann Thorac Surg; 2018 Sep; 106(3):685-690. PubMed ID: 29705366
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Surgical aortic valve replacement with new-generation bioprostheses: Sutureless versus rapid-deployment.
    D'Onofrio A; Salizzoni S; Filippini C; Tessari C; Bagozzi L; Messina A; Troise G; Tomba MD; Rambaldini M; Dalén M; Alamanni F; Massetti M; Mignosa C; Russo C; Salvador L; Di Bartolomeo R; Maselli D; De Paulis R; Alfieri O; De Filippo CM; Portoghese M; Bortolotti U; Rinaldi M; Gerosa G
    J Thorac Cardiovasc Surg; 2020 Feb; 159(2):432-442.e1. PubMed ID: 31213376
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Predictors of Pacemaker Insertion Post-Sutureless (Perceval) Aortic Valve Implantation.
    Brookes JDL; Mathew M; Brookes EM; Jaya JS; Almeida AA; Smith JA
    Heart Lung Circ; 2021 Jun; 30(6):917-921. PubMed ID: 33309876
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transcatheter Heart Valve Selection and Permanent Pacemaker Implantation in Patients With Pre-Existent Right Bundle Branch Block.
    van Gils L; Tchetche D; Lhermusier T; Abawi M; Dumonteil N; Rodriguez Olivares R; Molina-Martin de Nicolas J; Stella PR; Carrié D; De Jaegere PP; Van Mieghem NM
    J Am Heart Assoc; 2017 Mar; 6(3):. PubMed ID: 28258051
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Conduction disturbances following surgical aortic valve replacement with a rapid-deployment bioprosthesis.
    Coti I; Schukro C; Drevinja F; Haberl T; Kaider A; Kocher A; Laufer G; Andreas M
    J Thorac Cardiovasc Surg; 2021 Sep; 162(3):803-811. PubMed ID: 32204909
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Conduction Disorders After Sutureless Aortic Valve Replacement.
    Bouhout I; Mazine A; Rivard L; Ghoneim A; El-Hamamsy I; Lamarche Y; Carrier M; Demers P; Bouchard D
    Ann Thorac Surg; 2017 Apr; 103(4):1254-1260. PubMed ID: 27717423
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Early Conduction Disorders After Aortic Valve Replacement With the Sutureless Perceval Prosthesis.
    Verlinden J; Bové T; de Kerchove L; Baert J; Radermecker M; Durieux R; Gutermann H; Van Kerrebroeck C; Szecel D; Meuris B
    Ann Thorac Surg; 2022 Jun; 113(6):1911-1917. PubMed ID: 34536377
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Conduction disturbances and permanent cardiac pacing after transcatheter implantation of the CoreValve aortic bioprosthesis: initial single centre experience.
    Czerwińska K; Hryniewiecki T; Oręziak A; Dąbrowski M; Michałowska I; Witkowski A; Demkow M; Stępińska J; Orłowska Baranowska E; Rużyłło W
    Kardiol Pol; 2012; 70(2):121-8. PubMed ID: 22427074
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The influence of native aortic valve calcium and transcatheter valve oversize on the need for pacemaker implantation after transcatheter aortic valve insertion.
    Al-Azzam F; Greason KL; Krittanawong C; Williamson EE; McLeod CJ; King KS; Mathew V
    J Thorac Cardiovasc Surg; 2017 May; 153(5):1056-1062.e1. PubMed ID: 28073567
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Incidence of Persistent Left Bundle Branch Block After Rapid-Deployment Aortic Valve Replacement.
    Bouchat M; Pelce E; Porto A; Badaoui R; Resseguier N; Soler F; Mammari S; Gariboldi V; Collart F; Theron A
    Ann Thorac Surg; 2023 Jun; 115(6):1446-1454. PubMed ID: 35952857
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Postoperative conduction disorders after implantation of the self-expandable sutureless Perceval S bioprosthesis.
    van Boxtel AG; Houthuizen P; Hamad MA; Sjatskig J; Tan E; Prinzen FW; van Straten AH
    J Heart Valve Dis; 2014 May; 23(3):319-24. PubMed ID: 25296456
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Sutureless versus transcatheter aortic valves in elderly patients with aortic stenosis at intermediate risk: A multi-institutional study.
    Muneretto C; Solinas M; Folliguet T; Di Bartolomeo R; Repossini A; Laborde F; Rambaldini M; Santarpino G; Di Bacco L; Fischlein T
    J Thorac Cardiovasc Surg; 2022 Mar; 163(3):925-935.e5. PubMed ID: 32727681
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Need for permanent pacemaker as a complication of transcatheter aortic valve implantation and surgical aortic valve replacement in elderly patients with severe aortic stenosis and similar baseline electrocardiographic findings.
    Bagur R; Rodés-Cabau J; Gurvitch R; Dumont É; Velianou JL; Manazzoni J; Toggweiler S; Cheung A; Ye J; Natarajan MK; Bainey KR; DeLarochellière R; Doyle D; Pibarot P; Voisine P; Côté M; Philippon F; Webb JG
    JACC Cardiovasc Interv; 2012 May; 5(5):540-551. PubMed ID: 22625193
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hemodynamic Comparison of Sutureless and Rapid-Deployment Valves with Conventional Bioprostheses.
    Gotzmann M; Wilbring M; Charitos E; Treede H; Silaschi M
    Thorac Cardiovasc Surg; 2020 Oct; 68(7):584-594. PubMed ID: 30900219
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Conduction disorders and impact on survival after sutureless aortic valve replacement compared to conventional stented bioprostheses.
    Lam KY; Akca F; Verberkmoes NJ; van Dijk C; Claessens A; Soliman Hamad MA; van Straten AHM
    Eur J Cardiothorac Surg; 2019 Jun; 55(6):1168-1173. PubMed ID: 30561575
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.