BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 36154981)

  • 1. Are patients most satisfied with a synthetic or a biological mesh in dual-plane immediate breast reconstruction after 5 years? A randomized controlled trial comparing the two meshes in the same patient.
    Paganini A; Meyer S; Hallberg H; Hansson E
    J Plast Reconstr Aesthet Surg; 2022 Nov; 75(11):4133-4143. PubMed ID: 36154981
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of inflammatory response and synovial metaplasia in immediate breast reconstruction with a synthetic and a biological mesh: a randomized controlled clinical trial.
    Hansson E; Burian P; Hallberg H
    J Plast Surg Hand Surg; 2020 Jun; 54(3):131-136. PubMed ID: 31859575
    [TBL] [Abstract][Full Text] [Related]  

  • 3. First-year complications after immediate breast reconstruction with a biological and a synthetic mesh in the same patient: A randomized controlled study.
    Hansson E; Edvinsson AC; Elander A; Kölby L; Hallberg H
    J Surg Oncol; 2021 Jan; 123(1):80-88. PubMed ID: 33051871
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of subpectoral versus dual-plane implant based immediate breast reconstruction after nipple-areola sparing mastectomy.
    Ozgur I; Kurul S; Bademler S; Karanlik H
    Ann Chir Plast Esthet; 2021 Dec; 66(6):447-458. PubMed ID: 33223365
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Implant-based immediate reconstruction in prophylactic mastectomy: is the caudal dermis flap a reliable alternative to synthetic mesh or acellular dermal matrix?
    Heine N; Hoesl V; Seitz S; Prantl L; Brebant V
    Arch Gynecol Obstet; 2022 Apr; 305(4):937-943. PubMed ID: 34554314
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of Prepectoral Implant Placement and Complete Coverage with TiLoop Bra Mesh for Breast Reconstruction: A Prospective Study on Long-Term and Patient-Reported BREAST-Q Outcomes.
    Casella D; Di Taranto G; Marcasciano M; Sordi S; Kothari A; Kovacs T; Lo Torto F; Cigna E; Calabrese C; Ribuffo D
    Plast Reconstr Surg; 2019 Jan; 143(1):1e-9e. PubMed ID: 30303929
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Clinical outcomes and patient satisfaction with the use of biological and synthetic meshes in one-stage implant-based breast reconstruction.
    Gao P; Wang X; Bai P; Kong X; Wang Z; Fang Y; Wang J
    Breast Cancer; 2022 May; 29(3):450-457. PubMed ID: 34978672
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A biological or a synthetic mesh in immediate breast reconstruction? A cohort-study of long-term Health related Quality of Life (HrQoL).
    Hallberg H; Elander A; Kölby L; Hansson E
    Eur J Surg Oncol; 2019 Oct; 45(10):1812-1816. PubMed ID: 30905394
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Patient-reported outcomes of immediate implant-based breast reconstruction with and without biological or synthetic mesh.
    Sewart E; Turner NL; Conroy EJ; Cutress RI; Skillman J; Whisker L; Thrush S; Barnes N; Holcombe C; Potter S;
    BJS Open; 2021 Jan; 5(1):. PubMed ID: 33609398
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Nipple-sparing bilateral prophylactic mastectomy and immediate reconstruction with TiLoop
    Casella D; Di Taranto G; Marcasciano M; Sordi S; Kothari A; Kovacs T; Lo Torto F; Cigna E; Ribuffo D; Calabrese C
    Breast; 2018 Jun; 39():8-13. PubMed ID: 29455110
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Acellular dermal matrix and synthetic mesh in implant-based immediate breast reconstruction: Current concepts].
    Billon R; Hersant B; Bosc R; Meningaud JP
    Gynecol Obstet Fertil Senol; 2019 Mar; 47(3):311-316. PubMed ID: 30738819
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prepectoral Direct-to-Implant Breast Reconstruction without Placement of Acellular Dermal Matrix or Mesh after Nipple-Sparing Mastectomy.
    Urban C; González E; Fornazari A; Berman G; Spautz C; Kuroda F; Furlan Anselmi K; Rabinovich I; Dória M; Nissen L; Schünemann E; Sobreiro B; Lima R
    Plast Reconstr Surg; 2022 Nov; 150(5):973-983. PubMed ID: 35994351
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Mesh versus acellular dermal matrix in immediate implant-based breast reconstruction - A prospective randomized trial.
    Gschwantler-Kaulich D; Schrenk P; Bjelic-Radisic V; Unterrieder K; Leser C; Fink-Retter A; Salama M; Singer C
    Eur J Surg Oncol; 2016 May; 42(5):665-71. PubMed ID: 26947961
    [TBL] [Abstract][Full Text] [Related]  

  • 14. TiLoop Bra Assisted Breast Reconstruction - Our Experience.
    Krivorotko PV; Pesotsky RS; Zernov KY; Zhiltsova EK; Tabagua TT; Bessonov AA; Komyahov AV; Nikolaev KS; Rychagov KY; Gigolaeva LP; Zirov KY; Aseeva ZA; Emelyanov AS; Enaldieva DA; Bondarchuk YI; Levchenko VE; Belyaev AM; Semiglazov VF
    Chirurgia (Bucur); 2021; 116(2 Suppl):84-90. PubMed ID: 33963697
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Drain secretion and seroma formation after immediate breast reconstruction with a biological and a synthetic mesh, respectively: A randomized controlled study.
    Hansson E; Edvinsson AC; Hallberg H
    Breast J; 2020 Sep; 26(9):1756-1759. PubMed ID: 32515840
    [TBL] [Abstract][Full Text] [Related]  

  • 16. RED BREAST SYNDROME (RBS) ASSOCIATED TO THE USE OF POLYGLYCOLIC MESH IN BREAST RECONSTRUCTION: A CASE REPORT.
    Mayer HF; Perez Colman M; Stoppani I
    Acta Chir Plast; 2020; 62(1-2):50-52. PubMed ID: 32911943
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Implant-based breast reconstruction with meshes and matrices: biological vs synthetic.
    Jacobs JM; Salzberg CA
    Br J Hosp Med (Lond); 2015 Apr; 76(4):211-6. PubMed ID: 25853352
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Management of Implant Exposure in One-Stage Breast Reconstruction Using Titanium-Coated Polypropylene Mesh: Sub-Mammary Intercostal Perforator Flap.
    De Riggi MA; Rocco N; Gherardini G; Esposito E; D'Aiuto M
    Aesthetic Plast Surg; 2016 Dec; 40(6):896-900. PubMed ID: 27766402
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Implant-based breast reconstruction using a titanium-coated polypropylene mesh (TiLOOP Bra): a multicenter study of 231 cases.
    Dieterich M; Paepke S; Zwiefel K; Dieterich H; Blohmer J; Faridi A; Klein E; Gerber B; Nestle-Kraemling C
    Plast Reconstr Surg; 2013 Jul; 132(1):8e-19e. PubMed ID: 23806958
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparing the Outcomes and Complication Rates of Biologic vs Synthetic Meshes in Implant-Based Breast Reconstruction: A Systematic Review.
    Makarewicz N; Perrault D; Sharma A; Shaheen M; Kim J; Calderon C; Sweeney B; Nazerali R
    Ann Plast Surg; 2023 May; 90(5):516-527. PubMed ID: 37146317
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.