219 related articles for article (PubMed ID: 36155591)
1. A sample-to-answer DNA detection microfluidic system integrating sample pretreatment and smartphone-readable gradient plasmonic photothermal continuous-flow PCR.
Zhang Z; Zhao S; Jiang L; Wu J; Zhao W; Guo X; Peng N; Hu F
Analyst; 2022 Oct; 147(21):4876-4887. PubMed ID: 36155591
[TBL] [Abstract][Full Text] [Related]
2. Mkit: A mobile nucleic acid assay based on a chitosan-modified minimalistic microfluidic chip (CM
Yang K; Pan J; Deng G; Hua C; Zhu C; Liu Y; Zhu L
Anal Chim Acta; 2023 May; 1253():341030. PubMed ID: 36965987
[TBL] [Abstract][Full Text] [Related]
3. Smartphone clip-on instrument and microfluidic processor for rapid sample-to-answer detection of Zika virus in whole blood using spatial RT-LAMP.
Jankelow AM; Lee H; Wang W; Hoang TH; Bacon A; Sun F; Chae S; Kindratenko V; Koprowski K; Stavins RA; Ceriani DD; Engelder ZW; King WP; Do MN; Bashir R; Valera E; Cunningham BT
Analyst; 2022 Aug; 147(17):3838-3853. PubMed ID: 35726910
[TBL] [Abstract][Full Text] [Related]
4. An approach for integrating droplet generation and detection in digital polymerase chain reaction applications based on a bifunctional microfluidic cross-structure.
Wang J; Lyu X; Zhang X; Wang S; Zeng W; Yang T; Wang B; Luo G
Talanta; 2024 Jan; 267():125240. PubMed ID: 37778182
[TBL] [Abstract][Full Text] [Related]
5. Sample-to-Answer Hepatitis B Virus DNA Detection from Whole Blood on a Centrifugal Microfluidic Platform with Double Rotation Axes.
Li L; Miao B; Li Z; Sun Z; Peng N
ACS Sens; 2019 Oct; 4(10):2738-2745. PubMed ID: 31502439
[TBL] [Abstract][Full Text] [Related]
6. Digital PCR using a simple PDMS microfluidic chip and standard laboratory equipment.
Hosokawa K; Ohmori H
Anal Sci; 2023 Dec; 39(12):2067-2074. PubMed ID: 37710081
[TBL] [Abstract][Full Text] [Related]
7. A sample-to-answer, quantitative real-time PCR system with low-cost, gravity-driven microfluidic cartridge for rapid detection of SARS-CoV-2, influenza A/B, and human papillomavirus 16/18.
Zai Y; Min C; Wang Z; Ding Y; Zhao H; Su E; He N
Lab Chip; 2022 Sep; 22(18):3436-3452. PubMed ID: 35972195
[TBL] [Abstract][Full Text] [Related]
8. Living algae detection with a PDMS-liquid chlorophyll fluorescence microfluidic chip filter and a smartphone.
Liu J; Chang H; Zhang X; Chen S; Song Y; Li D
Analyst; 2022 Aug; 147(16):3723-3731. PubMed ID: 35829696
[TBL] [Abstract][Full Text] [Related]
9. A plasmonic gold nanofilm-based microfluidic chip for rapid and inexpensive droplet-based photonic PCR.
Jalili A; Bagheri M; Shamloo A; Kazemipour Ashkezari AH
Sci Rep; 2021 Dec; 11(1):23338. PubMed ID: 34857792
[TBL] [Abstract][Full Text] [Related]
10. LabDisk with complete reagent prestorage for sample-to-answer nucleic acid based detection of respiratory pathogens verified with influenza A H3N2 virus.
Stumpf F; Schwemmer F; Hutzenlaub T; Baumann D; Strohmeier O; Dingemanns G; Simons G; Sager C; Plobner L; von Stetten F; Zengerle R; Mark D
Lab Chip; 2016 Jan; 16(1):199-207. PubMed ID: 26610171
[TBL] [Abstract][Full Text] [Related]
11. Facile prepared microfluidic chip for multiplexed digital RT-qPCR test.
Hu W; Zhu Y; Tang Q; Ji X; Wang L; Ou W; Li G; Wu L; Cong H; Qin Y
Biotechnol J; 2024 Jan; 19(1):e2300273. PubMed ID: 37702130
[TBL] [Abstract][Full Text] [Related]
12. Miniaturized and IoT Enabled Continuous-Flow-Based Microfluidic PCR Device for DNA Amplification.
Kulkarni MB; Goyal S; Dhar A; Sriram D; Goel S
IEEE Trans Nanobioscience; 2022 Jan; 21(1):97-104. PubMed ID: 34170829
[TBL] [Abstract][Full Text] [Related]
13. Simultaneous amplification of DNA in a multiplex circular array shaped continuous flow PCR microfluidic chip for on-site detection of bacterial.
Yang B; Wang P; Li Z; You Q; Sekine S; Ma J; Zhuang S; Zhang D; Yamaguchi Y
Lab Chip; 2023 May; 23(11):2633-2639. PubMed ID: 37170867
[TBL] [Abstract][Full Text] [Related]
14. A Smartphone-Enabled Continuous Flow Digital Droplet LAMP Platform for High Throughput and Inexpensive Quantitative Detection of Nucleic Acid Targets.
Ditchendorf E; Ahmed I; Sepate J; Priye A
Sensors (Basel); 2023 Oct; 23(19):. PubMed ID: 37837140
[TBL] [Abstract][Full Text] [Related]
15. Lower fluidic resistance of double-layer droplet continuous flow PCR microfluidic chip for rapid detection of bacteria.
Li Z; Wang Y; Gao Z; Sekine S; You Q; Zhuang S; Zhang D; Feng S; Yamaguchi Y
Anal Chim Acta; 2023 Apr; 1251():340995. PubMed ID: 36925286
[TBL] [Abstract][Full Text] [Related]
16. Integrated electrochemical microsystems for genetic detection of pathogens at the point of care.
Hsieh K; Ferguson BS; Eisenstein M; Plaxco KW; Soh HT
Acc Chem Res; 2015 Apr; 48(4):911-20. PubMed ID: 25785632
[TBL] [Abstract][Full Text] [Related]
17. Mobile Platform for Multiplexed Detection and Differentiation of Disease-Specific Nucleic Acid Sequences, Using Microfluidic Loop-Mediated Isothermal Amplification and Smartphone Detection.
Chen W; Yu H; Sun F; Ornob A; Brisbin R; Ganguli A; Vemuri V; Strzebonski P; Cui G; Allen KJ; Desai SA; Lin W; Nash DM; Hirschberg DL; Brooks I; Bashir R; Cunningham BT
Anal Chem; 2017 Nov; 89(21):11219-11226. PubMed ID: 28819973
[TBL] [Abstract][Full Text] [Related]
18. Comparative analysis of loop-mediated isothermal amplification combined with microfluidic chip technology and q-PCR in the detection of clinical infectious pathogens.
Zhang E; Ou H; Jia L; Zhang W; Wang Y; Wang X
J Clin Lab Anal; 2022 Aug; 36(8):e24565. PubMed ID: 35754145
[TBL] [Abstract][Full Text] [Related]
19. Microfluidic gradient PCR (MG-PCR): a new method for microfluidic DNA amplification.
Zhang C; Xing D
Biomed Microdevices; 2010 Feb; 12(1):1-12. PubMed ID: 19757072
[TBL] [Abstract][Full Text] [Related]
20. Digital microfluidic meter-on-chip.
Fang Z; Ding Y; Zhang Z; Wang F; Wang Z; Wang H; Pan T
Lab Chip; 2020 Feb; 20(4):722-733. PubMed ID: 31853525
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]