108 related articles for article (PubMed ID: 3616427)
1. [Activation of solid materials in a medical linear electron accelerator].
Ewen K; Lauber-Altmann I
Rontgenblatter; 1987 Jun; 40(6):185-90. PubMed ID: 3616427
[TBL] [Abstract][Full Text] [Related]
2. Activation processes in a medical linear accelerator and spatial distribution of activation products.
Fischer HW; Tabot BE; Poppe B
Phys Med Biol; 2006 Dec; 51(24):N461-6. PubMed ID: 17148816
[TBL] [Abstract][Full Text] [Related]
3. Induced radioactive nuclides of 10-MeV radiotherapy accelerators detected by using a portable HP-Ge survey meter.
Fujibuchi T; Obara S; Yamaguchi I; Oyama M; Watanabe H; Sakae T; Katoh K
Radiat Prot Dosimetry; 2012 Jan; 148(2):168-73. PubMed ID: 21317145
[TBL] [Abstract][Full Text] [Related]
4. Neutron production from a mobile linear accelerator operating in electron mode for intraoperative radiation therapy.
Loi G; Dominietto M; Cannillo B; Ciocca M; Krengli M; Mones E; Negri E; Brambilla M
Phys Med Biol; 2006 Feb; 51(3):695-702. PubMed ID: 16424589
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of the radioactivity of the pre-dominant gamma emitters in components used at high-energy proton accelerator facilities.
Numajiri M
Radiat Prot Dosimetry; 2007; 123(4):417-25. PubMed ID: 17164270
[TBL] [Abstract][Full Text] [Related]
6. Skyshine radiation resulting from 6 MV and 10 MV photon beams from a medical accelerator.
Elder DH; Harmon JF; Borak TB
Health Phys; 2010 Jul; 99(1):17-25. PubMed ID: 20539121
[TBL] [Abstract][Full Text] [Related]
7. A measuring system with a recombination chamber for neutron dosimetry around medical accelerators.
Golnik N; Kamiński P; Zielczyński M
Radiat Prot Dosimetry; 2004; 110(1-4):273-6. PubMed ID: 15353658
[TBL] [Abstract][Full Text] [Related]
8. Induced radioactivity in CU targets produced by high-energy heavy ions and the corresponding estimated photon dose rates.
Yashima H; Uwamino Y; Sugita H; Ito S; Nakamura T; Fukumura A
Radiat Prot Dosimetry; 2004; 112(2):195-208. PubMed ID: 15280565
[TBL] [Abstract][Full Text] [Related]
9. Contribution of activation products to occupational exposure following treatment using high-energy photons in radiotherapy.
Petrović N; Krestić-Vesović J; Stojanović D; Ciraj-Bjelac O; Lazarević D; Kovacević M
Radiat Prot Dosimetry; 2011 Jan; 143(1):109-12. PubMed ID: 20947589
[TBL] [Abstract][Full Text] [Related]
10. Generation and modelling of megavoltage photon beams for contrast-enhanced radiation therapy.
Robar JL
Phys Med Biol; 2006 Nov; 51(21):5487-504. PubMed ID: 17047265
[TBL] [Abstract][Full Text] [Related]
11. On the existence of low-energy photons (<150 keV) in the unflattened x-ray beam from an ordinary radiotherapeutic target in a medical linear accelerator.
Tsechanski A; Krutman Y; Faermann S
Phys Med Biol; 2005 Dec; 50(23):5629-39. PubMed ID: 16306657
[TBL] [Abstract][Full Text] [Related]
12. Experimental simulation of A-bomb gamma ray spectra: revisited.
Pattison JE; Payne LC; Hugtenburg RP; Beddoe AH; Charles MW
Radiat Prot Dosimetry; 2004; 109(3):175-80. PubMed ID: 15254320
[TBL] [Abstract][Full Text] [Related]
13. Comparison of activation products and induced dose rates in different high-energy medical linear accelerators.
Fischer HW; Tabot B; Poppe B
Health Phys; 2008 Mar; 94(3):272-8. PubMed ID: 18301101
[TBL] [Abstract][Full Text] [Related]
14. Health physics aspects of neutron activated components in a linear accelerator.
Guo S; Ziemer PL
Health Phys; 2004 May; 86(5 Suppl):S94-S102. PubMed ID: 15069298
[TBL] [Abstract][Full Text] [Related]
15. Shielding design for a laser-accelerated proton therapy system.
Fan J; Luo W; Fourkal E; Lin T; Li J; Veltchev I; Ma CM
Phys Med Biol; 2007 Jul; 52(13):3913-30. PubMed ID: 17664585
[TBL] [Abstract][Full Text] [Related]
16. Shielding analysis of the Microtron MT-25 bunker using the MCNP-4C code and NCRP Report 51.
Casanova AO; López N; Gelen A; Guevara MV; Díaz O; Cimino L; D'Alessandro K; Melo JC
Radiat Prot Dosimetry; 2004; 109(3):189-95. PubMed ID: 15254322
[TBL] [Abstract][Full Text] [Related]
17. Experimental determination of peripheral doses for different IMRT techniques delivered by a Siemens linear accelerator.
Wiezorek T; Voigt A; Metzger N; Georg D; Schwedas M; Salz H; Wendt TG
Strahlenther Onkol; 2008 Feb; 184(2):73-9. PubMed ID: 18259698
[TBL] [Abstract][Full Text] [Related]
18. Shielding evaluation of a medical linear accelerator vault in preparation for installing a high-dose rate 252Cf remote afterloader.
Melhus CS; Rivard MJ; Kurkomelis J; Liddle CB; Massé FX
Radiat Prot Dosimetry; 2005; 113(4):428-37. PubMed ID: 15755770
[TBL] [Abstract][Full Text] [Related]
19. Towards an optimum design of a P-MOS radiation detector for use in high-energy medical photon beams and neutron facilities: analysis of activation materials.
Price RA
Radiat Prot Dosimetry; 2005; 115(1-4):386-90. PubMed ID: 16381751
[TBL] [Abstract][Full Text] [Related]
20. The effect of field modifier blocks on the fast photoneutron dose equivalent from two high-energy medical linear accelerators.
Hashemi SM; Hashemi-Malayeri B; Raisali G; Shokrani P; Sharafi AA; Jafarizadeh M
Radiat Prot Dosimetry; 2008; 128(3):359-62. PubMed ID: 17875628
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]