BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 36179127)

  • 1. Quantitative analysis of tissue area of endoscopic ultrasound-guided liver biopsy specimens using 19-gauge fine-needle biopsy needle in patients with diffuse liver disease: A single-center retrospective study.
    Matsumoto K; Doi S; Watanabe A; Katsukura N; Tsujikawa T; Takahashi M; Kikuchi K
    J Hepatobiliary Pancreat Sci; 2023 May; 30(5):678-685. PubMed ID: 36179127
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Endoscopic ultrasound-guided liver biopsy using a 22-G fine needle biopsy needle: a prospective study.
    Hasan MK; Kadkhodayan K; Idrisov E; Ali S; Rafiq E; Ben-Ami Shor D; Abdel-Jalil A; Navaneethan U; Bang J; Varadarajulu S; Hawes R; Pernicone P
    Endoscopy; 2019 Sep; 51(9):818-824. PubMed ID: 31365947
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of Two Specialized Histology Needles for Endoscopic Ultrasound (EUS)-Guided Liver Biopsy: A Pilot Study.
    Hashimoto R; Lee DP; Samarasena JB; Chandan VS; Guo W; Lee JG; Chang KJ
    Dig Dis Sci; 2021 May; 66(5):1700-1706. PubMed ID: 32556821
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Efficacy and safety of EUS-guided liver biopsy: a systematic review and meta-analysis.
    Mohan BP; Shakhatreh M; Garg R; Ponnada S; Adler DG
    Gastrointest Endosc; 2019 Feb; 89(2):238-246.e3. PubMed ID: 30389469
    [TBL] [Abstract][Full Text] [Related]  

  • 5. "Wet Heparin" and "Wet Saline" EUS-Guided Liver Biopsy Techniques Both Provide High Rates of Specimen Adequacy for Benign Parenchymal Liver Disease.
    Saraireh H; Abdelfattah T; Hassouneh R; Lippman R; Puri P; Mutha P; Singh S; Fuchs M; Shah T
    Dig Dis Sci; 2022 Nov; 67(11):5256-5261. PubMed ID: 35169957
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparing a 19-gauge fine-needle biopsy needle with a 22-gauge fine-needle biopsy needle for EUS-guided liver biopsy sampling: a prospective randomized study.
    Diehl DL; Sangwan V; Johal AS; Khara HS; Confer B
    Gastrointest Endosc; 2024 Jun; 99(6):931-937. PubMed ID: 38141686
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The efficacy and safety of endoscopic ultrasound-guided liver biopsy versus percutaneous liver biopsy in patients with chronic liver disease: a retrospective single-center study.
    Ali AH; Panchal S; Rao DS; Gan Y; Al-Juboori A; Samiullah S; Ibdah JA; Hammoud GM
    J Ultrasound; 2020 Jun; 23(2):157-167. PubMed ID: 32141043
    [TBL] [Abstract][Full Text] [Related]  

  • 8. 19 G aspiration needle versus 19 G core biopsy needle for endoscopic ultrasound-guided liver biopsy: a prospective randomized trial.
    Ching-Companioni RA; Diehl DL; Johal AS; Confer BD; Khara HS
    Endoscopy; 2019 Nov; 51(11):1059-1065. PubMed ID: 31342474
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Update on endoscopic ultrasound-guided liver biopsy.
    Rangwani S; Ardeshna DR; Mumtaz K; Kelly SG; Han SY; Krishna SG
    World J Gastroenterol; 2022 Jul; 28(28):3586-3594. PubMed ID: 36161047
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Endoscopic ultrasound-guided liver biopsy using a single-pass, slow-pull technique with a 19-G Franseen tip fine-needle biopsy needle: A prospective study.
    Rai P; Majeed A; Kumar P; Rajput M; Goel A; Rao RN
    Indian J Gastroenterol; 2023 Jun; 42(3):418-424. PubMed ID: 37097513
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A Comparative Study of 22G versus 19G Needles for EUS-Guided Biopsies for Parenchymal Liver Disease: Are Thinner Needles Better?
    Patel HK; Saxena R; Rush N; Patel SK; Dasari CS; Mneimneh W; Quickery A; Rahal MA; Temnykh L; DeWitt J; Al-Haddad M
    Dig Dis Sci; 2021 Jan; 66(1):238-246. PubMed ID: 32128647
    [TBL] [Abstract][Full Text] [Related]  

  • 12. EUS-guided fine-needle core liver biopsy sampling using a novel 19-gauge needle with modified 1-pass, 1 actuation wet suction technique.
    Nieto J; Khaleel H; Challita Y; Jimenez M; Baron TH; Walters L; Hathaway K; Patel K; Lankarani A; Herman M; Holloman D; Saab S
    Gastrointest Endosc; 2018 Feb; 87(2):469-475. PubMed ID: 28551024
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Role of endoscopic ultrasound-guided liver biopsy: a meta-analysis.
    Zeng K; Jiang Z; Yang J; Chen K; Lu Q
    Scand J Gastroenterol; 2022 May; 57(5):545-557. PubMed ID: 35049405
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Diagnostic yield of endoscopic ultrasound-guided liver biopsy in comparison to percutaneous liver biopsy: a systematic review and meta-analysis.
    Facciorusso A; Crinò SF; Ramai D; Fabbri C; Mangiavillano B; Lisotti A; Muscatiello N; Cotsoglou C; Fusaroli P
    Expert Rev Gastroenterol Hepatol; 2022 Jan; 16(1):51-57. PubMed ID: 34918578
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quality of Tissue Samples Obtained by Endoscopic Ultrasound-Guided Liver Biopsy: A Randomized, Controlled Clinical Trial.
    Lariño-Noia J; Fernández-Castroagudín J; de la Iglesia-García D; Lázare H; Nieto L; Porto S; Vallejo-Senra N; Molina E; San Bruno A; Martínez-Seara X; Iglesias-García J; García-Acuña S; Domínguez-Muñoz JE
    Am J Gastroenterol; 2023 Oct; 118(10):1821-1828. PubMed ID: 37439519
    [TBL] [Abstract][Full Text] [Related]  

  • 16. EUS-guided liver biopsy provides diagnostic samples comparable with those via the percutaneous or transjugular route.
    Pineda JJ; Diehl DL; Miao CL; Johal AS; Khara HS; Bhanushali A; Chen EZ
    Gastrointest Endosc; 2016 Feb; 83(2):360-5. PubMed ID: 26301407
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Endoscopic ultrasound with combined fine needle aspiration plus biopsy improves diagnostic yield in solid pancreatic masses.
    Gonzalez A; Wadhwa V; Singh H; Khan S; Gupta K; Liang H; Hussain I; Vargo J; Jang S; Chahal P; Bhatt A; Siddiki H; Erim T; Sanaka MR
    Scand J Gastroenterol; 2022 May; 57(5):610-617. PubMed ID: 34991430
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Endoscopic Ultrasound-Guided Fine Needle Biopsy Using 22-Gauge Franseen Needle for the Histological Diagnosis of Solid Lesions: A Multicenter Prospective Pilot Study.
    Mita N; Iwashita T; Uemura S; Iwasa Y; Toda K; Mukai T; Miyazaki T; Yasuda I; Shimizu M
    Dig Dis Sci; 2020 Apr; 65(4):1155-1163. PubMed ID: 31531819
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Touch imprint cytology on endoscopic ultrasound fine-needle biopsy provides comparable sample quality and diagnostic yield to standard endoscopic ultrasound fine-needle aspiration specimens in the evaluation of solid pancreatic lesions.
    Crinò SF; Larghi A; Bernardoni L; Parisi A; Frulloni L; Gabbrielli A; Parcesepe P; Scarpa A; Manfrin E
    Cytopathology; 2019 Mar; 30(2):179-186. PubMed ID: 30484917
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Single-pass 1-needle actuation versus single-pass 3-needle actuation technique for EUS-guided liver biopsy sampling: a randomized prospective trial (with video).
    Ching-Companioni RA; Johal AS; Confer BD; Forster E; Khara HS; Diehl DL
    Gastrointest Endosc; 2021 Sep; 94(3):551-558. PubMed ID: 33771557
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.