These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

106 related articles for article (PubMed ID: 36182500)

  • 1. Conceptual study for velocity space resolved thermal ion loss detection in tokamaks.
    Poley-Sanjuán J; Galdón-Quiroga J; Viezzer E; Rueda-Rueda J; Cano-Megias P; Oyola P; Cruz-Zabala DJ;
    Rev Sci Instrum; 2022 Sep; 93(9):093511. PubMed ID: 36182500
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A rotary and reciprocating scintillator based fast-ion loss detector for the MAST-U tokamak.
    Rivero-Rodriguez JF; Garcia-Munoz M; Martin R; Galdon-Quiroga J; Ayllon-Guerola J; Akers RJ; Buchanan J; Croft D; Garcia-Vallejo D; Gonzalez-Martin J; Harvey D; McClements KG; Rodriguez-Ramos M; Sanchis L
    Rev Sci Instrum; 2018 Oct; 89(10):10I112. PubMed ID: 30399654
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Scintillator-based fast ion loss measurements in the EAST.
    Chang JF; Isobe M; Ogawa K; Huang J; Wu CR; Xu Z; Jin Z; Lin SY; Hu LQ;
    Rev Sci Instrum; 2016 Nov; 87(11):11E728. PubMed ID: 27910330
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Near midplane scintillator-based fast ion loss detector on DIII-D.
    Chen X; Fisher RK; Pace DC; García-Muñoz M; Chavez JA; Heidbrink WW; Van Zeeland MA
    Rev Sci Instrum; 2012 Oct; 83(10):10D707. PubMed ID: 23126881
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Scintillator based energetic ion loss diagnostic for the National Spherical Torus Experiment.
    Darrow DS
    Rev Sci Instrum; 2008 Feb; 79(2 Pt 1):023502. PubMed ID: 18315294
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Conceptual design of the ITER fast-ion loss detector.
    Garcia-Munoz M; Kocan M; Ayllon-Guerola J; Bertalot L; Bonnet Y; Casal N; Galdon J; Garcia Lopez J; Giacomin T; Gonzalez-Martin J; Gunn JP; Jimenez-Ramos MC; Kiptily V; Pinches SD; Rodriguez-Ramos M; Reichle R; Rivero-Rodriguez JF; Sanchis-Sanchez L; Snicker A; Vayakis G; Veshchev E; Vorpahl C; Walsh M; Walton R
    Rev Sci Instrum; 2016 Nov; 87(11):11D829. PubMed ID: 27910499
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Energetic ion loss detector on the Alcator C-Mod tokamak.
    Pace DC; Granetz RS; Vieira R; Bader A; Bosco J; Darrow DS; Fiore C; Irby J; Parker RR; Parkin W; Reinke ML; Terry JL; Wolfe SM; Wukitch SJ; Zweben SJ
    Rev Sci Instrum; 2012 Jul; 83(7):073501. PubMed ID: 22852689
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Scintillator-based diagnostic for fast ion loss measurements on DIII-D.
    Fisher RK; Pace DC; García-Muñoz M; Heidbrink WW; Muscatello CM; Van Zeeland MA; Zhu YB
    Rev Sci Instrum; 2010 Oct; 81(10):10D307. PubMed ID: 21033833
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Performance of fast-ion loss diagnostic on EAST.
    Wu CR; Huang J; Chang JF; Zhang J; Zhou RJ; Xu Z; Gao W; Isobe M; Ogawa K; Lin SY; Hu LQ; Li JG;
    Rev Sci Instrum; 2018 Oct; 89(10):10I144. PubMed ID: 30399726
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mapping and uncertainty analysis of energy and pitch angle phase space in the DIII-D fast ion loss detector.
    Pace DC; Pipes R; Fisher RK; Van Zeeland MA
    Rev Sci Instrum; 2014 Nov; 85(11):11D841. PubMed ID: 25430254
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Initial measurements of fast ion loss in KSTAR.
    Kim J; Kim JY; Yoon SW; García-Muñoz M; Isobe M; Kim WC
    Rev Sci Instrum; 2012 Oct; 83(10):10D305. PubMed ID: 23126832
    [TBL] [Abstract][Full Text] [Related]  

  • 12. First measurements of a scintillator based fast-ion loss detector near the ASDEX Upgrade divertor.
    Gonzalez-Martin J; Ayllon-Guerola J; Garcia-Munoz M; Herrmann A; Leitenstern P; De Marne P; Zoletnik S; Kovacsik A; Galdon-Quiroga J; Rivero-Rodriguez J; Rodriguez-Ramos M; Sanchis-Sanchez L; Dominguez J; ;
    Rev Sci Instrum; 2018 Oct; 89(10):10I106. PubMed ID: 30399966
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Electron multiplier-scintillator detector for pulse counting positive or negative ions.
    Dietz LA; Hanrahan LR
    Rev Sci Instrum; 1978 Sep; 49(9):1250. PubMed ID: 18699296
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The bipolar charge plasma spectrometer (BCPS) based on the 2π-field-of-view double-channel electrostatic analyzer.
    Su B; Kong LG; Zhang AB; Tian Z; Wang WJ; Lv YL; Ma LY
    Rev Sci Instrum; 2022 Apr; 93(4):043305. PubMed ID: 35489956
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Velocity-space sensitivities of neutron emission spectrometers at the tokamaks JET and ASDEX Upgrade in deuterium plasmas.
    Jacobsen AS; Binda F; Cazzaniga C; Eriksson J; Hjalmarsson A; Nocente M; Salewski M; Tardini G; ;
    Rev Sci Instrum; 2017 Jul; 88(7):073506. PubMed ID: 28764505
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measuring small field profiles and output factors with a stemless plastic scintillator array.
    Hupman MA; Hill IG; Syme A
    Med Phys; 2022 Jan; 49(1):624-631. PubMed ID: 34792193
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Design and simulation of an imaging neutral particle analyzer for the ASDEX Upgrade tokamak.
    Rueda-Rueda J; García-Muñoz M; Viezzer E; Schneider PA; García-Domínguez J; Ayllon-Guerola J; Galdón-Quiroga J; Herrmann A; Du XD; Van Zeeland MA; Oyola P; Rodriguez-Ramos M;
    Rev Sci Instrum; 2021 Apr; 92(4):043554. PubMed ID: 34243403
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ion-induced gamma-ray detection of fast ions escaping from fusion plasmas.
    Nishiura M; Doi K; Taniike A; Matsuki T; Shimazoe K; Mushiake T; Yoshino M; Nagasaka T; Fujimoto Y; Fujioka K; Tanaka T; Kisaki M; Yamaoka H; Matsumoto Y; Wada M
    Rev Sci Instrum; 2014 Nov; 85(11):11E804. PubMed ID: 25430369
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Spectroscopic measurement of ion temperature and ion velocity distributions in the flux-coil generated FRC.
    Gupta D; Bolte N; Gota H; Hayashi R; Kiyashko V; Marsili P; Morehouse M; Primavera S; Roche T; Wessel F
    Rev Sci Instrum; 2010 Oct; 81(10):10D730. PubMed ID: 21033923
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Measurement of the D alpha spectrum produced by fast ions in DIII-D.
    Luo Y; Heidbrink WW; Burrell KH; Kaplan DH; Gohil P
    Rev Sci Instrum; 2007 Mar; 78(3):033505. PubMed ID: 17411183
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.