BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 36184268)

  • 1. Minimally invasive plate osteosynthesis for displaced midshaft clavicle fractures: An indirect reduction using joystick technique.
    Jirangkul P; Kosiyatrakul A; Lorsuwannarat N
    J Orthop Sci; 2023 Nov; 28(6):1365-1372. PubMed ID: 36184268
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Minimally invasive plate osteosynthesis technique for displaced midshaft clavicular fracture using the clavicle reductor.
    Zhang T; Chen W; Sun J; Zhang Q; Zhang Y
    Int Orthop; 2017 Aug; 41(8):1679-1683. PubMed ID: 28083672
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Precontoured dynamic compression plate using patient-specific 3D-printed models in minimally invasive surgical technique for midshaft clavicle fractures.
    Jirangkul P; Lorsuwannarat N; Wanichjaroen N
    Arch Orthop Trauma Surg; 2024 Jan; 144(1):103-111. PubMed ID: 37658855
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison between open plating versus minimally invasive plate osteosynthesis for acute displaced clavicular shaft fractures.
    Sohn HS; Kim WJ; Shon MS
    Injury; 2015 Aug; 46(8):1577-84. PubMed ID: 26077663
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Minimally invasive plate osteosynthesis for midshaft clavicular fractures using superior anatomic plating.
    Zhang Y; Xu J; Zhang C; Sun Y
    J Shoulder Elbow Surg; 2016 Jan; 25(1):e7-12. PubMed ID: 26256015
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparative study of patients with midshaft clavicle fracture fixed with a locked plate via an open versus percutaneous approach.
    Machado do Amaral F; Angeli Malavolta E; Brandao Andrade E Silva F; Garcia JC; da Silva Moura J; Assunção JH; Pecora JR
    Injury; 2023 Nov; 54 Suppl 6():110746. PubMed ID: 38143119
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Minimally invasive plate osteosynthesis (MIPO) in AO/OTA type B displaced clavicle fractures.
    Kundangar RS; Mohanty SP; Bhat NS
    Musculoskelet Surg; 2019 Aug; 103(2):191-197. PubMed ID: 30519988
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Minimally invasive osteosynthesis with blocked anatomical plate in displaced fractures of the middle third of the clavicle].
    Cárdenas G
    Acta Ortop Mex; 2021; 35(5):479-485. PubMed ID: 35451261
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Surgical Treatment of Clavicle Midshaft Fractures - Prospective Randomized Trial].
    Šimek J; Šmejkal K; Frank M; Hyšpler R; Dědek T; Páral J
    Acta Chir Orthop Traumatol Cech; 2020; 87(2):101-107. PubMed ID: 32396510
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Minimally invasive plating for fresh displaced midshaft fractures of the clavicle.
    Tieyi Y; Shuyi L; Yan Z; Guohua H; Jin S; Rui J
    Orthopedics; 2014 Oct; 37(10):679-83. PubMed ID: 25275968
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Operative treatment of clavicle midshaft fractures using a locking compression plate: comparison between mini-invasive plate osteosynthesis (MIPPO) technique and conventional open reduction.
    Jiang H; Qu W
    Orthop Traumatol Surg Res; 2012 Oct; 98(6):666-71. PubMed ID: 23000038
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of post-operative numbness and patient satisfaction using minimally invasive plate osteosynthesis or open plating for acute displaced clavicular shaft fractures.
    You JM; Wu YS; Wang Y
    Int J Surg; 2018 Aug; 56():21-25. PubMed ID: 29890301
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Clinical comparison of two different plating methods in minimally invasive plate osteosynthesis for clavicular midshaft fractures: A randomized controlled trial.
    Sohn HS; Shon MS; Lee KH; Song SJ
    Injury; 2015 Nov; 46(11):2230-8. PubMed ID: 26363573
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Minimally invasive plate osteosynthesis using anterior-inferior plating of clavicular midshaft fractures.
    Sohn HS; Shin SJ; Kim BY
    Arch Orthop Trauma Surg; 2012 Feb; 132(2):239-44. PubMed ID: 22006573
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A surgical technique for minimally invasive plate osteosynthesis of clavicular midshaft fractures.
    Sohn HS; Kim BY; Shin SJ
    J Orthop Trauma; 2013 Apr; 27(4):e92-6. PubMed ID: 22773015
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Minimally invasive plate osteosynthesis of clavicular midshaft fractures under insertion guide.
    Ko MS; Ri KI; Mun TW; Song KI; Choe KI
    Ulus Travma Acil Cerrahi Derg; 2021 Sep; 27(5):552-557. PubMed ID: 34476796
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Clinical outcome of internal fixation of middle third clavicle fractures using locking compression plate: comparison between conventional open plating and minimally invasive plate osteosynthesis].
    Zheng ST; Hu X; Zhao EZ
    Zhonghua Yi Xue Za Zhi; 2023 Jul; 103(25):1897-1902. PubMed ID: 37402670
    [No Abstract]   [Full Text] [Related]  

  • 18. Open reduction and plate fixation versus nonoperative treatment for displaced midshaft clavicular fractures: a multicenter, randomized, controlled trial.
    Robinson CM; Goudie EB; Murray IR; Jenkins PJ; Ahktar MA; Read EO; Foster CJ; Clark K; Brooksbank AJ; Arthur A; Crowther MA; Packham I; Chesser TJ
    J Bone Joint Surg Am; 2013 Sep; 95(17):1576-84. PubMed ID: 24005198
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Minimally invasive plate osteosynthesis for clavicle fractures.
    Michelitsch C; Beeres F; Burkhard MD; Stillhard PF; Babst R; Sommer C
    Oper Orthop Traumatol; 2023 Apr; 35(2):92-99. PubMed ID: 36723629
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Surgical treatment of mid-shaft clavicle fractures by minimally invasive internal fixation facilitated by intra-operative external fixation: A preliminary study.
    Delvaque JG; Bégué T; Villain B; Mebtouche N; Aurégan JC
    Orthop Traumatol Surg Res; 2019 Sep; 105(5):847-852. PubMed ID: 30975635
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.