These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 36187891)

  • 1. Measurement of oxygen consumption rates of human renal proximal tubule cells in an array of organ-on-chip devices to monitor drug-induced metabolic shifts.
    Kann SH; Shaughnessey EM; Coppeta JR; Azizgolshani H; Isenberg BC; Vedula EM; Zhang X; Charest JL
    Microsyst Nanoeng; 2022; 8():109. PubMed ID: 36187891
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High-throughput organ-on-chip platform with integrated programmable fluid flow and real-time sensing for complex tissue models in drug development workflows.
    Azizgolshani H; Coppeta JR; Vedula EM; Marr EE; Cain BP; Luu RJ; Lech MP; Kann SH; Mulhern TJ; Tandon V; Tan K; Haroutunian NJ; Keegan P; Rogers M; Gard AL; Baldwin KB; de Souza JC; Hoefler BC; Bale SS; Kratchman LB; Zorn A; Patterson A; Kim ES; Petrie TA; Wiellette EL; Williams C; Isenberg BC; Charest JL
    Lab Chip; 2021 Apr; 21(8):1454-1474. PubMed ID: 33881130
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Online oxygen monitoring using integrated inkjet-printed sensors in a liver-on-a-chip system.
    Moya A; Ortega-Ribera M; Guimerà X; Sowade E; Zea M; Illa X; Ramon E; Villa R; Gracia-Sancho J; Gabriel G
    Lab Chip; 2018 Jul; 18(14):2023-2035. PubMed ID: 29892739
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Renal proximal tubule-on-a-chip in PDMS: fabrication, functionalization, and RPTEC:HUVEC co-culture evaluation.
    Guimaraes APP; Calori IR; Stilhano RS; Tedesco AC
    Biofabrication; 2024 Mar; 16(2):. PubMed ID: 38408383
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Multicompartment Human Kidney Proximal Tubule-on-a-Chip Replicates Cell Polarization-Dependent Cisplatin Toxicity.
    Nieskens TTG; Persson M; Kelly EJ; Sjögren AK
    Drug Metab Dispos; 2020 Dec; 48(12):1303-1311. PubMed ID: 33020068
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Organ chips with integrated multifunctional sensors enable continuous metabolic monitoring at controlled oxygen levels.
    Izadifar Z; Charrez B; Almeida M; Robben S; Pilobello K; van der Graaf-Mas J; Marquez SL; Ferrante TC; Shcherbina K; Gould R; LoGrande NT; Sesay AM; Ingber DE
    Biosens Bioelectron; 2024 Dec; 265():116683. PubMed ID: 39213819
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Steady-state monitoring of oxygen in a high-throughput organ-on-chip platform enables rapid and non-invasive assessment of drug-induced nephrotoxicity.
    Kann SH; Shaughnessey EM; Zhang X; Charest JL; Vedula EM
    Analyst; 2023 Jul; 148(14):3204-3216. PubMed ID: 37307041
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Microfluidic-Based Oxygen (O
    Azimzadeh M; Khashayar P; Amereh M; Tasnim N; Hoorfar M; Akbari M
    Biosensors (Basel); 2021 Dec; 12(1):. PubMed ID: 35049634
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Barrier-on-a-Chip with a Modular Architecture and Integrated Sensors for Real-Time Measurement of Biological Barrier Function.
    Zoio P; Lopes-Ventura S; Oliva A
    Micromachines (Basel); 2021 Jul; 12(7):. PubMed ID: 34357226
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Tunable In Situ Synthesis of Ultrathin Extracellular Matrix-Derived Membranes in Organ-on-a-Chip Devices.
    Newton JD; Song Y; Park S; Kanagarajah KR; Wong AP; Young EWK
    Adv Healthc Mater; 2024 Aug; 13(20):e2401158. PubMed ID: 38587309
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Functional Evaluation and Nephrotoxicity Assessment of Human Renal Proximal Tubule Cells on a Chip.
    Jing B; Yan L; Li J; Luo P; Ai X; Tu P
    Biosensors (Basel); 2022 Sep; 12(9):. PubMed ID: 36140103
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Design engineering of a bioartificial renal tubule cell therapy device.
    Nikolovski J; Gulari E; Humes HD
    Cell Transplant; 1999; 8(4):351-64. PubMed ID: 10478715
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Circadian hormone control in a human-on-a-chip: In vitro biology's ignored component?
    Cyr KJ; Avaldi OM; Wikswo JP
    Exp Biol Med (Maywood); 2017 Nov; 242(17):1714-1731. PubMed ID: 29065796
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Methods of Delivering Mechanical Stimuli to Organ-on-a-Chip.
    Kaarj K; Yoon JY
    Micromachines (Basel); 2019 Oct; 10(10):. PubMed ID: 31615136
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of the three optical platforms for measurement of cellular respiration.
    Kondrashina AV; Ogurtsov VI; Papkovsky DB
    Anal Biochem; 2015 Jan; 468():1-3. PubMed ID: 25233002
    [TBL] [Abstract][Full Text] [Related]  

  • 16. 3D Cell Printing of Advanced Vascularized Proximal Tubule-on-a-Chip for Drug Induced Nephrotoxicity Advancement.
    Singh NK; Kim JY; Jang J; Kim YK; Cho DW
    ACS Appl Bio Mater; 2023 Sep; 6(9):3750-3758. PubMed ID: 37606916
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Human kidney proximal tubule-on-a-chip for drug transport and nephrotoxicity assessment.
    Jang KJ; Mehr AP; Hamilton GA; McPartlin LA; Chung S; Suh KY; Ingber DE
    Integr Biol (Camb); 2013 Sep; 5(9):1119-29. PubMed ID: 23644926
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Organ-on-a-Chip Platform with an Integrated Screen-Printed Electrode Array for Real-Time Monitoring Trans-Epithelial Barrier and Bubble Formation.
    Krishnakumar A; Kadian S; Heredia Rivera U; Chittiboyina S; Lelièvre SA; Rahimi R
    ACS Biomater Sci Eng; 2023 Mar; 9(3):1620-1628. PubMed ID: 36763005
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In situ, dual-mode monitoring of organ-on-a-chip with smartphone-based fluorescence microscope.
    Cho S; Islas-Robles A; Nicolini AM; Monks TJ; Yoon JY
    Biosens Bioelectron; 2016 Dec; 86():697-705. PubMed ID: 27474967
    [TBL] [Abstract][Full Text] [Related]  

  • 20. UniChip enables long-term recirculating unidirectional perfusion with gravity-driven flow for microphysiological systems.
    Wang YI; Shuler ML
    Lab Chip; 2018 Aug; 18(17):2563-2574. PubMed ID: 30046784
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.