  • 1. [Reprogramming of a pacemaker induced by electrocautery].
    Caramella JP; Mentre B; Jattiot F; Strouk R; Delétang D
    Ann Fr Anesth Reanim; 1987; 6(3):214-6. PubMed ID: 3619157
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Final arrest of a pacemaker after use of electrocautery].
    Delhumeau A; Ronceray S; Moreau X; Cottineau C; Cavellat M
    Ann Fr Anesth Reanim; 1988; 7(2):162-4. PubMed ID: 3364815
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Electrocautery and pacemakers: management of the paced patient subject to electrocautery.
    Levine PA; Balady GJ; Lazar HL; Belott PH; Roberts AJ
    Ann Thorac Surg; 1986 Mar; 41(3):313-7. PubMed ID: 3954504
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Surgical electrocautery and the runaway pacemaker syndrome.
    Heller LI
    Pacing Clin Electrophysiol; 1990 Sep; 13(9):1084-5. PubMed ID: 1700378
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intraoperative pacemaker failure in an infant.
    Bailey AG; Lacey SR
    Can J Anaesth; 1991 Oct; 38(7):912-3. PubMed ID: 1742829
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Open heart surgery in a patient with an implanted pacemaker: case report.
    Kuo KK; Chiu CC; Chen YF; Lin YT
    Gaoxiong Yi Xue Ke Xue Za Zhi; 1993 Feb; 9(2):113-7. PubMed ID: 8492352
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Electrocautery-induced pacemaker malfunction during surgery.
    Mangar D; Atlas GM; Kane PB
    Can J Anaesth; 1991 Jul; 38(5):616-8. PubMed ID: 1934215
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Electrocautery-induced ventricular tachycardia and fibrillation during device implantation and explantation.
    Lo R; Mitrache A; Quan W; Cohen TJ
    J Invasive Cardiol; 2007 Jan; 19(1):12-5. PubMed ID: 17297178
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Safety precautions in the management of patients with pacemakers when electrocautery operations are performed.
    Erdman S; Levinsky L; Servadio C; Stoupel E; Levy MJ
    Surg Gynecol Obstet; 1988 Oct; 167(4):311-4. PubMed ID: 2458629
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reversible prolonged pacemaker failure due to electrocautery.
    Peters RW; Gold MR
    J Interv Card Electrophysiol; 1998 Dec; 2(4):343-4. PubMed ID: 10027119
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Monomorphic ventricular tachycardia caused by electrocautery during pacemaker generator change in a patient with normal left ventricular function.
    Goel AK; Korotkin S; Walsh D; Bess M; Frawley S
    Pacing Clin Electrophysiol; 2009 Jul; 32(7):957-8. PubMed ID: 19572878
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Intraoperative pacemaker dysfunction caused by the use of electrocautery during a total hip arthroplasty.
    Nercessian OA; Wu H; Nazarian D; Mahmud F
    J Arthroplasty; 1998 Aug; 13(5):599-602. PubMed ID: 9726329
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Electrocautery-induced reprogramming of a pacemaker using a precordial magnet.
    Domino KB; Smith TC
    Anesth Analg; 1983 Jun; 62(6):609-12. PubMed ID: 6846885
    [No Abstract]   [Full Text] [Related]  

  • 14. Electrocautery-induced asystole in a scoliosis patient with a pacemaker.
    Bales JG; Colon J; Ramadhyani U; LeDoux E; Bennett JT
    J Pediatr Orthop B; 2007 Jan; 16(1):19-22. PubMed ID: 17159528
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Rapid ventricular pacing due to electrocautery: a case report and review.
    Wilson S; Neustein SN; Camunas J
    Mt Sinai J Med; 2006 Oct; 73(6):880-3. PubMed ID: 17117315
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effects of surgical and endoscopic electrocautery on modern-day permanent pacemaker and implantable cardioverter-defibrillator systems.
    Cheng A; Nazarian S; Spragg DD; Bilchick K; Tandri H; Mark L; Halperin H; Calkins H; Berger RD; Henrikson CA
    Pacing Clin Electrophysiol; 2008 Mar; 31(3):344-50. PubMed ID: 18307631
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Interference between a dual-chamber pacemaker and argon electrocautery device during hepatectomy].
    Werner P; Charbit B; Samain E; Farah E; Marty J
    Ann Fr Anesth Reanim; 2001 Oct; 20(8):716-9. PubMed ID: 11695291
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Interaction between electrocautery and a pacemaker].
    Richard JP; Conil JM; Antonini A; Bareille P
    Ann Fr Anesth Reanim; 1986; 5(1):72-3. PubMed ID: 2422991
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Upper limit ventricular stimulation in respiratory rate responsive pacing due to electrocautery.
    Van Hemel NM; Hamerlijnck RP; Pronk KJ; Van der Veen EP
    Pacing Clin Electrophysiol; 1989 Nov; 12(11):1720-3. PubMed ID: 2478969
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [A case of cardiac arrest caused by electrocautery during surgical pacemaker implanting (author's transl)].
    Omote T; Namiki A; Dohi S; Takahashi T; Ohhori K
    Masui; 1981 Oct; 30(10):1126-9. PubMed ID: 7328734
    [No Abstract]   [Full Text] [Related]  