These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 36192510)

  • 1. Efficacy of thermoplastic polyurethane and gelatin blended nanofibers covered stent graft in the porcine iliac artery.
    Ryu DS; Won DS; Kim JW; Park Y; Kim SH; Kang JM; Zeng CH; Lim D; Choi H; Park JH
    Sci Rep; 2022 Oct; 12(1):16524. PubMed ID: 36192510
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of a microporous thermoplastic polyurethane-covered stent with a self-expanding bare nitinol stent in a porcine iliac artery model.
    Radeleff B; Grenacher L; Christoph P; Sommer CM; Stampfl U; Ramsauer S; Henn T; Kurz P; Lopez-Benitez R; Berger I; Richter GM
    J Vasc Interv Radiol; 2009 Jul; 20(7):927-35. PubMed ID: 19497761
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Efficacy of closed cell self expandable metallic stent for peripheral arterial disease in the porcine iliac artery.
    Ryu DS; Won DS; Kim JW; Park Y; Kim SH; Kang JM; Zeng CH; Lim D; Choi H; Park JH
    Sci Rep; 2023 May; 13(1):8601. PubMed ID: 37237009
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effect of an intraluminal stent on neointimal hyperplasia at an end-to-side polytetrafluoroethylene graft arterial anastomosis.
    Chalmers RT; Hoballah JJ; Sharp WJ; Kresowik TF; Corson JD
    Am J Surg; 1994 Aug; 168(2):85-90. PubMed ID: 7519832
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Rapamycin-coated expanded polytetrafluoroethylene bypass grafts exhibit decreased anastomotic neointimal hyperplasia in a porcine model.
    Cagiannos C; Abul-Khoudoud OR; DeRijk W; Shell DH; Jennings LK; Tolley EA; Handorf CR; Fabian TC
    J Vasc Surg; 2005 Nov; 42(5):980-8. PubMed ID: 16275457
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mechanically tuned vascular graft demonstrates rapid endothelialization and integration into the porcine iliac artery wall.
    Maleckis K; Kamenskiy A; Lichter EZ; Oberley-Deegan R; Dzenis Y; MacTaggart J
    Acta Biomater; 2021 Apr; 125():126-137. PubMed ID: 33549808
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of a Novel Spun Polytetrafluoroethylene Stent Graft in an Ovine External Iliac Artery Model.
    Dolmatch BL; Hall JW; Mower WL; Rousselle SD
    J Vasc Interv Radiol; 2020 Mar; 31(3):494-502. PubMed ID: 31959517
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Stent versus endovascular graft healing characteristics in the porcine iliac artery.
    Yee DC; Williams SK; Salzmann DL; Pond GD; Patula V; Berman SS; Roach DJ
    J Vasc Interv Radiol; 1998; 9(4):609-17. PubMed ID: 9684832
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biocompatibility and performance of the Wallstent and several covered stents in a sheep iliac artery model.
    Cejna M; Virmani R; Jones R; Bergmeister H; Losert U; Xu Z; Yang P; Schoder M; Lammer J
    J Vasc Interv Radiol; 2001 Mar; 12(3):351-8. PubMed ID: 11287514
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The in vivo performance of small-caliber nanofibrous polyurethane vascular grafts.
    Hu ZJ; Li ZL; Hu LY; He W; Liu RM; Qin YS; Wang SM
    BMC Cardiovasc Disord; 2012 Dec; 12():115. PubMed ID: 23206536
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of polytetrafluoroethylene covering of Palmaz stents on the development of intimal hyperplasia in human iliac arteries.
    Marin ML; Veith FJ; Cynamon J; Parsons RE; Lyon RT; Suggs WD; Bakal CW; Waahl S; Sanchez LA; Yuan JG; Ohki T
    J Vasc Interv Radiol; 1996; 7(5):651-6. PubMed ID: 8897327
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Iliac arteries: plain and heparin-coated Dacron-covered stent-grafts compared with noncovered metal stents--an experimental study.
    Schürmann K; Vorwerk D; Uppenkamp R; Klosterhalfen B; Bücker A; Günther RW
    Radiology; 1997 Apr; 203(1):55-63. PubMed ID: 9122416
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of three polytetrafluoroethylene stent-grafts in a model of neointimal hyperplasia.
    Dolmatch B; Dong YH; Heeter Z
    J Vasc Interv Radiol; 2007 Apr; 18(4):527-34. PubMed ID: 17446544
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Inhibition of experimental neointimal hyperplasia by recombinant human thrombomodulin coated ePTFE stent grafts.
    Wong G; Li JM; Hendricks G; Eslami MH; Rohrer MJ; Cutler BS
    J Vasc Surg; 2008 Mar; 47(3):608-15. PubMed ID: 18295112
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Histologic Analysis with the Newly Designed Exoskeleton Seal
    Park JH; Cho YK; Her K; Jeon YS; Kim JH; Seo TS; Song MG
    Cardiovasc Intervent Radiol; 2019 Sep; 42(9):1331-1342. PubMed ID: 31201508
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of straight and Venaflo-type cuffed arteriovenous ePTFE grafts in an animal study.
    Heise M; Husmann I; Grüneberg AK; Knobel A; Kirschner P; Heidenhain C
    J Vasc Surg; 2011 Jun; 53(6):1661-7. PubMed ID: 21459546
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improvement of patency rate in heparin-coated small synthetic vascular grafts.
    Walpoth BH; Rogulenko R; Tikhvinskaia E; Gogolewski S; Schaffner T; Hess OM; Althaus U
    Circulation; 1998 Nov; 98(19 Suppl):II319-23; discussion II324. PubMed ID: 9852921
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of diamond-like carbon-coated nitinol stents with or without polyethylene glycol grafting and uncoated nitinol stents in a canine iliac artery model.
    Kim JH; Shin JH; Shin DH; Moon MW; Park K; Kim TH; Shin KM; Won YH; Han DK; Lee KR
    Br J Radiol; 2011 Mar; 84(999):210-5. PubMed ID: 21325363
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Nonbiodegradable expanded polytetrafluoroethylene-covered stent implantation in porcine peripheral arteries: histologic evaluation of vascular wall response compared with uncoated stents.
    Sangiorgi G; Arbustini E; Lanzarini P; del Bello B; Maestri M; Gaspari A; Solcia M; Virmani R; Inglese L
    Cardiovasc Intervent Radiol; 2001; 24(4):260-70. PubMed ID: 11779017
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Patency and tissue response related to two types of polytetrafluoroethylene-covered stents in the dog.
    Dolmatch BL; Tio FO; Li XD; Dong YH
    J Vasc Interv Radiol; 1996; 7(5):641-9. PubMed ID: 8897326
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.