166 related articles for article (PubMed ID: 36195517)
21. Medial buttress plate augmentation of cannulated screw fixation in vertically unstable femoral neck fractures: Surgical technique and preliminary results.
Ye Y; Chen K; Tian K; Li W; Mauffrey C; Hak DJ
Injury; 2017 Oct; 48(10):2189-2193. PubMed ID: 28818323
[TBL] [Abstract][Full Text] [Related]
22. Internal fixation of type-C distal femoral fractures in osteoporotic bone.
Wähnert D; Hoffmeier KL; von Oldenburg G; Fröber R; Hofmann GO; Mückley T
J Bone Joint Surg Am; 2010 Jun; 92(6):1442-52. PubMed ID: 20516320
[TBL] [Abstract][Full Text] [Related]
23. Biomechanical properties of off-axis screw in Pauwels III femoral neck fracture fixation: Bicortical screw construct is superior to unicortical screw construct.
Kuan FC; Hsu KL; Lin CL; Hong CK; Yeh ML; Su WR
Injury; 2019 Nov; 50(11):1889-1894. PubMed ID: 31431332
[TBL] [Abstract][Full Text] [Related]
24. Biomechanical Research of Three Parallel Cannulated Compression Screws in Oblique Triangle Configuration for Fixation of Femoral Neck Unstable Fractures.
Zhang RY; Zhang WP; Yang GM; Wang DF; Su P; Zhang Y; Nie SB; Li J; Zhao Z; Li JT; Zhang LC; Tang PF
Orthop Surg; 2024 Apr; 16(4):953-964. PubMed ID: 38389204
[TBL] [Abstract][Full Text] [Related]
25. Augmentation by cerclage wire improves fixation of vertical shear femoral neck fractures-A biomechanical analysis.
Kuan FC; Yeh ML; Hong CK; Chiang FL; Jou IM; Wang PH; Su WR
Injury; 2016 Oct; 47(10):2081-2086. PubMed ID: 27461779
[TBL] [Abstract][Full Text] [Related]
26. Biomechanical analysis of distal femoral fracture fixation: dynamic condylar screw versus locked compression plate.
Narsaria N; Singh AK; Rastogi A; Singh V
J Orthop Sci; 2014 Sep; 19(5):770-5. PubMed ID: 24859176
[TBL] [Abstract][Full Text] [Related]
27. Screw-blade fixation systems in Pauwels three femoral neck fractures: a biomechanical evaluation.
Knobe M; Altgassen S; Maier KJ; Gradl-Dietsch G; Kaczmarek C; Nebelung S; Klos K; Kim BS; Gueorguiev B; Horst K; Buecking B
Int Orthop; 2018 Feb; 42(2):409-418. PubMed ID: 28780597
[TBL] [Abstract][Full Text] [Related]
28. Comparison of Ordinary Cannulated Compression Screw and Double-Head Cannulated Compression Screw Fixation in Vertical Femoral Neck Fractures.
Zhang Y; Yan C; Zhang L; Zhang W; Wang G
Biomed Res Int; 2020; 2020():2814548. PubMed ID: 33457404
[TBL] [Abstract][Full Text] [Related]
29. Biomechanical analysis of four types of internal fixation in subtrochanteric fracture models.
Wang J; Ma XL; Ma JX; Xing D; Yang Y; Zhu SW; Ma BY; Chen Y; Feng R; Jia HB; Yu JT
Orthop Surg; 2014 May; 6(2):128-36. PubMed ID: 24890295
[TBL] [Abstract][Full Text] [Related]
30. Finite element analysis of different medial fixation strategies in double-plate osteosynthesis for AO type 33-C2 Femoral fractures.
Li M; Jiang Y; Wang J; Xu G; Wang D; Li J; Zhang W
Injury; 2023 Apr; 54 Suppl 2():S86-S94. PubMed ID: 35219538
[TBL] [Abstract][Full Text] [Related]
31. Interlocked Pins Increase Strength by a Lateral Spread of Load in Femoral Neck Fixation: a Cadaver Study.
Brattgjerd JE; Niratisairak S; Steen H; Strømsøe K
Acta Chir Orthop Traumatol Cech; 2021; 88(2):144-152. PubMed ID: 33960928
[TBL] [Abstract][Full Text] [Related]
32. [Biomechanical comparative study on proximal femoral locking plate and Gamma3 for treatment of stable intertrochanteric fracture].
Jiang W; Liu Y; Yang L; Xu W; Liu S; Zhang D; Chen X; Wang H
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2014 Sep; 28(9):1096-9. PubMed ID: 25509773
[TBL] [Abstract][Full Text] [Related]
33. Mechanical comparison of endosteal substitution and lateral plate fixation in supracondylar fractures of the femur.
Prayson MJ; Datta DK; Marshall MP
J Orthop Trauma; 2001 Feb; 15(2):96-100. PubMed ID: 11232661
[TBL] [Abstract][Full Text] [Related]
34. Calcar screw position in proximal humerus fracture fixation: Don't miss high!
Mehta S; Chin M; Sanville J; Namdari S; Hast MW
Injury; 2018 Mar; 49(3):624-629. PubMed ID: 29452734
[TBL] [Abstract][Full Text] [Related]
35. Plate fixation for Letenneur type I Hoffa fracture: a biomechanical study.
Sun H; He QF; Huang YG; Pan JF; Luo CF; Chai YM
Injury; 2017 Jul; 48(7):1492-1498. PubMed ID: 28390685
[TBL] [Abstract][Full Text] [Related]
36. Clinical and Biomechanical Effects of Femoral Neck Buttress Plate used for Vertical Femoral Neck Fractures.
Steffensmeier A; Shah N; Archdeacon M; Watson D; Sanders RW; Sagi HC
Injury; 2022 Mar; 53(3):1137-1143. PubMed ID: 34916033
[TBL] [Abstract][Full Text] [Related]
37. [Research progress of medial buttress plate assisted fixation for femoral neck fractures in young adults].
Ni M; Sun W; Ye Y
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2020 Nov; 34(11):1454-1457. PubMed ID: 33191705
[TBL] [Abstract][Full Text] [Related]
38. Interfragmentary lag screw and locking plate combination in simple distal femoral fractures: A finite element analysis.
Zhang J; Wei Y; Li G; Wang J; Xu Y
Acta Orthop Traumatol Turc; 2021 Jan; 55(1):9-15. PubMed ID: 33650504
[TBL] [Abstract][Full Text] [Related]
39. [Research progress in biomechanics of common internal fixation for femoral neck fracture].
Wang F; Liu Y; Cheng L; Zhao D
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2022 Jul; 36(7):896-901. PubMed ID: 35848188
[TBL] [Abstract][Full Text] [Related]
40. A new configuration of cannulated screw fixation in the treatment of vertical femoral neck fractures.
Zhang B; Liu J; Zhu Y; Zhang W
Int Orthop; 2018 Aug; 42(8):1949-1955. PubMed ID: 29423638
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]