These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

313 related articles for article (PubMed ID: 36195825)

  • 1. Inotropes, vasopressors, and mechanical circulatory support for treatment of cardiogenic shock complicating myocardial infarction: a systematic review and network meta-analysis.
    Fernando SM; Mathew R; Sadeghirad B; Brodie D; Belley-Côté EP; Thiele H; van Diepen S; Fan E; Di Santo P; Simard T; Russo JJ; Tran A; Lévy B; Combes A; Hibbert B; Rochwerg B
    Can J Anaesth; 2022 Dec; 69(12):1537-1553. PubMed ID: 36195825
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Mechanical circulatory support versus vasopressors alone in patients with acute myocardial infarction and cardiogenic shock undergoing percutaneous coronary intervention.
    Javaid AI; Michalek JE; Gruslova AB; Hoskins SA; Ahsan CH; Feldman MD
    Catheter Cardiovasc Interv; 2024 Jan; 103(1):30-41. PubMed ID: 37997292
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Safety and efficacy of mechanical circulatory support with Impella or intra-aortic balloon pump for high-risk percutaneous coronary intervention and/or cardiogenic shock: Insights from a network meta-analysis of randomized trials.
    Kuno T; Takagi H; Ando T; Kodaira M; Numasawa Y; Fox J; Bangalore S
    Catheter Cardiovasc Interv; 2021 Apr; 97(5):E636-E645. PubMed ID: 32894797
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Percutaneous Mechanical Circulatory Support Versus Intra-Aortic Balloon Pump in Cardiogenic Shock After Acute Myocardial Infarction.
    Ouweneel DM; Eriksen E; Sjauw KD; van Dongen IM; Hirsch A; Packer EJ; Vis MM; Wykrzykowska JJ; Koch KT; Baan J; de Winter RJ; Piek JJ; Lagrand WK; de Mol BA; Tijssen JG; Henriques JP
    J Am Coll Cardiol; 2017 Jan; 69(3):278-287. PubMed ID: 27810347
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Association of Use of an Intravascular Microaxial Left Ventricular Assist Device vs Intra-aortic Balloon Pump With In-Hospital Mortality and Major Bleeding Among Patients With Acute Myocardial Infarction Complicated by Cardiogenic Shock.
    Dhruva SS; Ross JS; Mortazavi BJ; Hurley NC; Krumholz HM; Curtis JP; Berkowitz A; Masoudi FA; Messenger JC; Parzynski CS; Ngufor C; Girotra S; Amin AP; Shah ND; Desai NR
    JAMA; 2020 Feb; 323(8):734-745. PubMed ID: 32040163
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Intra-aortic balloon pump counterpulsation (IABP) for myocardial infarction complicated by cardiogenic shock.
    Unverzagt S; Buerke M; de Waha A; Haerting J; Pietzner D; Seyfarth M; Thiele H; Werdan K; Zeymer U; Prondzinsky R
    Cochrane Database Syst Rev; 2015 Mar; 2015(3):CD007398. PubMed ID: 25812932
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Intra-aortic balloon pump may grant no benefit to improve the mortality of patients with acute myocardial infarction in short and long term: an updated meta-analysis.
    Su D; Yan B; Guo L; Peng L; Wang X; Zeng L; Ong H; Wang G
    Medicine (Baltimore); 2015 May; 94(19):e876. PubMed ID: 25984680
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impella Support Versus Intra-Aortic Balloon Pump in Acute Myocardial Infarction Complicated by Cardiogenic Shock: A Meta-Analysis.
    Moustafa A; Khan MS; Saad M; Siddiqui S; Eltahawy E
    Cardiovasc Revasc Med; 2022 Jan; 34():25-31. PubMed ID: 33549497
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Long-term 5-year outcome of the randomized IMPRESS in severe shock trial: percutaneous mechanical circulatory support vs. intra-aortic balloon pump in cardiogenic shock after acute myocardial infarction.
    Karami M; Eriksen E; Ouweneel DM; Claessen BE; Vis MM; Baan J; Beijk M; Packer EJS; Sjauw KD; Engstrom A; Vlaar A; Lagrand WK; Henriques JPS
    Eur Heart J Acute Cardiovasc Care; 2021 Dec; 10(9):1009-1015. PubMed ID: 34327527
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intra-aortic balloon pump versus percutaneous Impella
    Frain K; Rees P
    Perfusion; 2024 Jan; 39(1):45-59. PubMed ID: 34479465
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of mechanical circulatory support devices in patients with acute myocardial infarction undergoing stent implantation: a systematic review and meta-analysis of randomised controlled trials.
    Shi Y; Wang Y; Sun X; Tang Y; Jiang M; Bai Y; Liu S; Jiang W; Yuan H; Lu Y; Cai J
    BMJ Open; 2021 Jun; 11(6):e044072. PubMed ID: 34187815
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mechanical circulatory support for cardiogenic shock: a network meta-analysis of randomized controlled trials and propensity score-matched studies.
    Low CJW; Ling RR; Lau MPXL; Liu NSH; Tan M; Tan CS; Lim SL; Rochwerg B; Combes A; Brodie D; Shekar K; Price S; MacLaren G; Ramanathan K
    Intensive Care Med; 2024 Feb; 50(2):209-221. PubMed ID: 38206381
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Feasibility of early mechanical circulatory support in acute myocardial infarction complicated by cardiogenic shock: The Detroit cardiogenic shock initiative.
    Basir MB; Schreiber T; Dixon S; Alaswad K; Patel K; Almany S; Khandelwal A; Hanson I; George A; Ashbrook M; Blank N; Abdelsalam M; Sareen N; Timmis SBH; O'Neill Md WW
    Catheter Cardiovasc Interv; 2018 Feb; 91(3):454-461. PubMed ID: 29266676
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Intra-aortic balloon pump counterpulsation (IABP) for myocardial infarction complicated by cardiogenic shock.
    Unverzagt S; Machemer MT; Solms A; Thiele H; Burkhoff D; Seyfarth M; de Waha A; Ohman EM; Buerke M; Haerting J; Werdan K; Prondzinsky R
    Cochrane Database Syst Rev; 2011 Jul; (7):CD007398. PubMed ID: 21735410
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effectiveness of intra-aortic balloon pump for myocardial infarction in patients with or without cardiogenic shock: a meta-analysis and systematic review.
    Zheng XY; Wang Y; Chen Y; Wang X; Chen L; Li J; Zheng ZG
    BMC Cardiovasc Disord; 2016 Jul; 16(1):148. PubMed ID: 27391391
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A systematic review and meta-analysis of intra-aortic balloon pump therapy in ST-elevation myocardial infarction: should we change the guidelines?
    Sjauw KD; Engström AE; Vis MM; van der Schaaf RJ; Baan J; Koch KT; de Winter RJ; Piek JJ; Tijssen JG; Henriques JP
    Eur Heart J; 2009 Feb; 30(4):459-68. PubMed ID: 19168529
    [TBL] [Abstract][Full Text] [Related]  

  • 17. INTRA-AORTIC BALLOON PUMP REDUCES 30-DAY MORTALITY IN EARLY-STAGE CARDIOGENIC SHOCK COMPLICATING ACUTE MYOCARDIAL INFARCTION ACCORDING TO SCAI CLASSIFICATION.
    Luo D; Huang R; Wang X; Zhang J; Cai X; Liu F; Lei Y; Li D; Zhou W; Xu C; Huang B; Jiang H; Chen J
    Shock; 2023 Sep; 60(3):385-391. PubMed ID: 37548623
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mechanical circulatory support in patients with cardiogenic shock not secondary to cardiotomy: a network meta-analysis.
    Benenati S; Toma M; Canale C; Vergallo R; Bona RD; Ricci D; Canepa M; Crimi G; Santini F; Ameri P; Porto I
    Heart Fail Rev; 2022 May; 27(3):927-934. PubMed ID: 33677732
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intra-aortic balloon pump in patients with cardiogenic shock complicating myocardial infarction: a systematic review and meta-analysis of randomized trials (protocol).
    Altayyar S; Rochwerg B; Alnasser S; Al-Omari A; Baw B; Fox-Robichaud A; Alhazzani W
    Syst Rev; 2014 Mar; 3():24. PubMed ID: 24620783
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Percutaneous short-term active mechanical support devices in cardiogenic shock: a systematic review and collaborative meta-analysis of randomized trials.
    Thiele H; Jobs A; Ouweneel DM; Henriques JPS; Seyfarth M; Desch S; Eitel I; Pöss J; Fuernau G; de Waha S
    Eur Heart J; 2017 Dec; 38(47):3523-3531. PubMed ID: 29020341
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.