These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 36200920)

  • 1. Effect of automated feedback laboratory comments promoting good phlebotomy practice on the frequency of ethylenediaminetetraacetic acid (EDTA) contamination of serum samples.
    Kalaria T; Ford C; Gama R
    Ann Clin Biochem; 2023 Jan; 60(1):63-67. PubMed ID: 36200920
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Order of draw of blood samples affect potassium results without K-EDTA contamination during routine workflow.
    Ercan Ş; Ramadan B; Gerenli O
    Biochem Med (Zagreb); 2021 Jun; 31(2):020704. PubMed ID: 33927554
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of order of draw of blood samples during phlebotomy on routine biochemistry results.
    Sulaiman RA; Cornes MP; Whitehead SJ; Othonos N; Ford C; Gama R
    J Clin Pathol; 2011 Nov; 64(11):1019-20. PubMed ID: 21778299
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Preanalytical potassium EDTA sample contamination: open versus closed phlebotomy systems.
    Asif U; Whitehead SJ; Ford C; Gama R
    Ann Clin Biochem; 2019 Nov; 56(6):711-714. PubMed ID: 31500437
    [No Abstract]   [Full Text] [Related]  

  • 5. Relevance of EDTA carryover during blood collection.
    Cadamuro J; Felder TK; Oberkofler H; Mrazek C; Wiedemann H; Haschke-Becher E
    Clin Chem Lab Med; 2015 Jul; 53(8):1271-8. PubMed ID: 25720083
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Managing ethylenediaminetetraacetic acid (EDTA) interference in EDTA contaminated samples - selectivity in reporting analytes.
    Kalaria T; Ford C; Gama R
    Ann Clin Biochem; 2023 Mar; 60(2):92-99. PubMed ID: 36348502
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Incorrect order of draw could be mitigate the patient safety: a phlebotomy management case report.
    Lima-Oliveira G; Lippi G; Salvagno GL; Montagnana M; Picheth G; Guidi GC
    Biochem Med (Zagreb); 2013; 23(2):218-23. PubMed ID: 23894868
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of using smaller blood volume tubes and closed blood collection devices on total blood loss in patients undergoing major cardiac and vascular surgery.
    Neef V; Himmele C; Piekarski F; Blum LV; Hof L; Derwich W; Holubec T; Meybohm P; Choorapoikayil S
    Can J Anaesth; 2024 Feb; 71(2):213-223. PubMed ID: 38191843
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Contamination of lithium heparin blood by K2-ethylenediaminetetraacetic acid (EDTA): an experimental evaluation.
    Lima-Oliveira G; Salvagno GL; Danese E; Brocco G; Guidi GC; Lippi G
    Biochem Med (Zagreb); 2014; 24(3):359-67. PubMed ID: 25351354
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Incorrect order of draw of blood samples does not cause potassium EDTA sample contamination.
    Cornes MR; Sulaiman RA; Whitehead SJ; Othonos N; Ford C; Gama R
    Br J Biomed Sci; 2012; 69(3):136-8. PubMed ID: 23057163
    [No Abstract]   [Full Text] [Related]  

  • 11. Sodium citrate blood contamination by K2 -ethylenediaminetetraacetic acid (EDTA): impact on routine coagulation testing.
    Lima-Oliveira G; Salvagno GL; Danese E; Favaloro EJ; Guidi GC; Lippi G
    Int J Lab Hematol; 2015 Jun; 37(3):403-9. PubMed ID: 25308126
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of test strips for the rapid identification of ethylenediaminetetraacetic acid (EDTA) specimens.
    Scholes KL; La'ulu SL; Ence AT; Logan HL; Parker RL; Strathmann FG; Genzen JR
    Lab Med; 2015; 46(2):97-108. PubMed ID: 25918188
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Towards Clinical Applications of Blood-Borne miRNA Signatures: The Influence of the Anticoagulant EDTA on miRNA Abundance.
    Leidinger P; Backes C; Rheinheimer S; Keller A; Meese E
    PLoS One; 2015; 10(11):e0143321. PubMed ID: 26599228
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Alternative pre-analytic sample handling techniques for glucose measurement in the absence of fluoride tubes in low resource settings.
    Nakanga WP; Balungi P; Niwaha AJ; Shields BM; Hughes P; Andrews RC; Mc Donald TJ; Nyirenda MJ; Hattersley AT
    PLoS One; 2022; 17(2):e0264432. PubMed ID: 35226681
    [TBL] [Abstract][Full Text] [Related]  

  • 15. EDTA sample contamination is common and often undetected, putting patients at unnecessary risk of harm.
    Sharratt CL; Gilbert CJ; Cornes MC; Ford C; Gama R
    Int J Clin Pract; 2009 Aug; 63(8):1259-62. PubMed ID: 19624792
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The order of draw: myth or science?
    Salvagno G; Lima-Oliveira G; Brocco G; Danese E; Guidi GC; Lippi G
    Clin Chem Lab Med; 2013 Dec; 51(12):2281-5. PubMed ID: 23846149
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Variation in phlebotomy techniques in emergency medicine and the incidence of haemolysed samples.
    Berg JE; Ahee P; Berg JD
    Ann Clin Biochem; 2011 Nov; 48(Pt 6):562-5. PubMed ID: 21948490
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Combined false hyperkalemia and hypocalcemia due to specimen contamination during routine phlebotomy.
    Naguib MT; Evans N
    South Med J; 2002 Oct; 95(10):1218-20. PubMed ID: 12425515
    [TBL] [Abstract][Full Text] [Related]  

  • 19. EDTA contamination in laboratory specimens-effect of an awareness campaign.
    Ijaz A; Maqsood-ul-Hassan ; Khan IM; Saeed F; Tariq KM
    J Coll Physicians Surg Pak; 2010 Jun; 20(6):405-7. PubMed ID: 20642972
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Phlebotomy overdraw in the neonatal intensive care nursery.
    Lin JC; Strauss RG; Kulhavy JC; Johnson KJ; Zimmerman MB; Cress GA; Connolly NW; Widness JA
    Pediatrics; 2000 Aug; 106(2):E19. PubMed ID: 10920175
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.