BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 36205608)

  • 1. Use of virtual reality for procedural planning of transcatheter aortic valve replacement.
    Ruyra X; Permanyer E; Huguet M; Maldonado G
    Interact Cardiovasc Thorac Surg; 2022 Oct; 35(5):. PubMed ID: 36205608
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Planning for Success: Pre-procedural Evaluation for Transcatheter Aortic Valve Replacement.
    Ng VG; Hahn RT; Nazif TM
    Cardiol Clin; 2020 Feb; 38(1):103-113. PubMed ID: 31753169
    [No Abstract]   [Full Text] [Related]  

  • 3. Clinical utility of intraprocedural three-dimensional integrated image guided transcatheter aortic valve implantation using novel automated computed tomography software: A single-center preliminary experience.
    Butter C; Kaneko H; Tambor G; Hara M; Neuss M; Hoelschermann F
    Catheter Cardiovasc Interv; 2019 Mar; 93(4):722-728. PubMed ID: 30408327
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Multidetector computed tomography in transcatheter aortic valve replacement: an update on technological developments and clinical applications.
    Abd Alamir M; Nazir S; Alani A; Golub I; Gilchrist IC; Aslam F; Dhawan P; Changal K; Ostra C; Soni R; Elzanaty A; Budoff M
    Expert Rev Cardiovasc Ther; 2020 Oct; 18(10):709-722. PubMed ID: 33063552
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Computed tomography (CT) assessment of the membranous septal anatomy prior to transcatheter aortic valve replacement (TAVR) with the balloon-expandable SAPIEN 3 valve.
    Oestreich BA; Mbai M; Gurevich S; Nijjar PS; Adabag S; Bertog S; Kelly R; Garcia S
    Cardiovasc Revasc Med; 2018; 19(5 Pt B):626-631. PubMed ID: 29352699
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Preoperative multidetector computed tomography for isolated surgical aortic valve replacement: Planning for future transcatheter options.
    Basman C; Seetharam K; Johnson J; Hemli JM; Brinster DR; Patel NC; Jacob Scheinerman S; Kliger CA; Pirelli L
    J Card Surg; 2020 Dec; 35(12):3354-3361. PubMed ID: 32996186
    [TBL] [Abstract][Full Text] [Related]  

  • 7. First-in-human transcatheter aortic valve-in-valve replacement with the SAPIEN 3 heart valve.
    Mancio J; Almeida C; Pires-Morais G; Ferreira W; Carvalho M; Rodrigues A; Santos L; Melica B; Oliveira M; Braga P; Ribeiro VG
    Int J Cardiol; 2015 Dec; 201():260-1. PubMed ID: 26301652
    [No Abstract]   [Full Text] [Related]  

  • 8. Computed Tomography Assessment for Transcatheter Aortic Valve Replacement.
    Alkhouli M; Winkler L; Tallaksen RJ
    Interv Cardiol Clin; 2018 Jul; 7(3):301-313. PubMed ID: 29983143
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Multimodality Imaging for Planning and Follow-up of Transcatheter Aortic Valve Replacement.
    Soon J; Pibarot P; Blanke P; Ohana M; Leipsic J
    Can J Cardiol; 2017 Sep; 33(9):1110-1123. PubMed ID: 28666614
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Transcatheter Valve Neo-Commissural Overlap With Coronary Orifices After Transcatheter Aortic Valve Replacement.
    Tang GHL; Zaid S; Ahmad H; Undemir C; Lansman SL
    Circ Cardiovasc Interv; 2018 Oct; 11(10):e007263. PubMed ID: 30354640
    [No Abstract]   [Full Text] [Related]  

  • 11. Comparison of self-expanding and balloon-expandable transcatheter aortic valves morphology and association with paravalvular regurgitation: Evaluation using multidetector computed tomography.
    Almeida JG; Ferreira SM; Fonseca P; Dias T; Guerreiro C; Barbosa A; Teixeira P; Carvalho M; Ferreira W; Ferreira ND; Braga P; Ribeiro J; Ribeiro VG
    Catheter Cardiovasc Interv; 2018 Sep; 92(3):533-541. PubMed ID: 29105953
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Impact of underfilling and overfilling in balloon-expandable transcatheter aortic valve implantation assessed by multidetector computed tomography: Insights from the Optimized CathEter vAlvular iNtervention (OCEAN-TAVI) registry.
    Yashima F; Yamamoto M; Watanabe Y; Takagi K; Yamada Y; Inohara T; Yanagisawa R; Tanaka M; Arai T; Shimizu H; Jinzaki M; Kozuma K; Fukuda K; Suzuki T; Hayashida K
    Int J Cardiol; 2016 Nov; 222():738-744. PubMed ID: 27521550
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Predictors for low TAVI-prosthesis position assessed by fusion imaging of pre- and post-procedural CT angiography.
    Breitbart P; Pache G; Minners J; Hein M; Schröfel H; Neumann FJ; Ruile P
    Clin Res Cardiol; 2021 Jan; 110(1):93-101. PubMed ID: 32399896
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Risk factors for paravalvular leak after transcatheter aortic valve replacement.
    Pollari F; Dell'Aquila AM; Söhn C; Marianowicz J; Wiehofsky P; Schwab J; Pauschinger M; Hitzl W; Fischlein T; Pfeiffer S
    J Thorac Cardiovasc Surg; 2019 Apr; 157(4):1406-1415.e3. PubMed ID: 30482527
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Relationship of Annular Sizing Using Multidetector Computed Tomographic Imaging and Clinical Outcomes After Self-Expanding CoreValve Transcatheter Aortic Valve Replacement.
    Popma JJ; Gleason TG; Yakubov SJ; Harrison JK; Forrest JK; Maini B; Ruiz CE; Pinto DS; Costa M; Resar J; Conte J; Crestanello J; Chang Y; Oh JK; Reardon MJ; Adams DH
    Circ Cardiovasc Interv; 2016 Jul; 9(7):. PubMed ID: 27369803
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A novel contribution towards coherent and reproducible intravalvular measurement of the aortic annulus by multidetector computed tomography ahead of transcatheter aortic valve implantation.
    Dementhon J; Rioufol G; Obadia JF; Vergnat M; Green L; Croisille P; Boussel L; Peron J; Revel D; Finet G
    Arch Cardiovasc Dis; 2015 May; 108(5):281-92. PubMed ID: 25863427
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Impact of Repositioning on Outcomes Following Transcatheter Aortic Valve Replacement With a Self-Expandable Valve.
    Attizzani GF; Dallan LAP; Markowitz A; Yakubov SJ; Deeb GM; Reardon MJ; Forrest JK; Mangi AA; Huang J; Popma JJ
    JACC Cardiovasc Interv; 2020 Aug; 13(15):1816-1824. PubMed ID: 32763073
    [TBL] [Abstract][Full Text] [Related]  

  • 18. TAVI in Bicuspid Aortic Valves 'Made Easy'.
    Frangieh AH; Kasel AM
    Eur Heart J; 2017 Apr; 38(16):1177-1181. PubMed ID: 28934845
    [No Abstract]   [Full Text] [Related]  

  • 19. Computed Tomography-Based Indexed Aortic Annulus Size to Predict Prosthesis-Patient Mismatch.
    Head SJ; Reardon MJ; Deeb GM; Van Mieghem NM; Popma JJ; Gleason TG; Williams MR; Radhakrishnan S; Fremes S; Oh JK; Chang Y; Boulware MJ; Kappetein AP
    Circ Cardiovasc Interv; 2019 Apr; 12(4):e007396. PubMed ID: 30929507
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Impact of valvular resistance on aortic regurgitation after transcatheter aortic valve replacement according to the type of prosthesis.
    Asami M; Pilgrim T; Stortecky S; Heg D; Roost E; Windecker S; Hunziker L
    Clin Res Cardiol; 2019 Dec; 108(12):1343-1353. PubMed ID: 30929034
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.