BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 3621522)

  • 1. Causes of failure and pathologic findings in surgically removed Ionescu-Shiley standard bovine pericardial heart valve bioprostheses: emphasis on progressive structural deterioration.
    Schoen FJ; Fernandez J; Gonzalez-Lavin L; Cernaianu A
    Circulation; 1987 Sep; 76(3):618-27. PubMed ID: 3621522
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pathology of the Pericarbon bovine pericardial xenograft implanted in humans.
    Valente M; Ius P; Bortolotti U; Talenti E; Bottio T; Thiene G
    J Heart Valve Dis; 1998 Mar; 7(2):180-9. PubMed ID: 9587859
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fatigue-induced failure of the Ionescu-Shiley pericardial xenograft in the mitral position. In vivo and in vitro correlation and a proposed classification.
    Gabbay S; Bortolotti U; Wasserman F; Factor S; Strom J; Frater RW
    J Thorac Cardiovasc Surg; 1984 Jun; 87(6):836-44. PubMed ID: 6727407
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Morphologic findings and causes of failure in 24 explanted Ionescu-Shiley low-profile pericardial heart valves.
    Butany J; Vanlerberghe K; Silver MD
    Hum Pathol; 1992 Nov; 23(11):1224-33. PubMed ID: 1427752
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Porcine aortic versus bovine pericardial valves: a comparative study of unimplanted and from patient explanted bioprostheses.
    Goffin YA; Bartik MA
    Life Support Syst; 1987; 5(2):127-43. PubMed ID: 3669720
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pathologic findings in explanted clinical bioprosthetic valves fabricated from photooxidized bovine pericardium.
    Schoen FJ
    J Heart Valve Dis; 1998 Mar; 7(2):174-9. PubMed ID: 9587858
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A morphologic study of Carpentier-Edwards pericardial xenografts in the mitral position exhibiting primary tissue failure in adults in comparison with Ionescu-Shiley pericardial xenografts.
    Machida H; Ishibashi-Ueda H; Nakano K; Sasako Y; Kobayashi J; Bando K; Minatoya K; Imamura H; Kitamura S
    J Thorac Cardiovasc Surg; 2001 Oct; 122(4):649-55. PubMed ID: 11581594
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Anatomic analysis of removed prosthetic heart valves: causes of failure of 33 mechanical valves and 58 bioprostheses, 1980 to 1983.
    Schoen FJ; Hobson CE
    Hum Pathol; 1985 Jun; 16(6):549-59. PubMed ID: 3997132
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Valve failure caused by cusp tears in low-profile Ionescu-Shiley bovine pericardial bioprosthetic valves.
    Walley VM; Bédard P; Brais M; Keon WJ
    J Thorac Cardiovasc Surg; 1987 Apr; 93(4):583-6. PubMed ID: 3550298
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Porcine versus pericardial bioprostheses: a comparison of late results in 1,593 patients.
    Pelletier LC; Carrier M; Leclerc Y; Lepage G; deGuise P; Dyrda I
    Ann Thorac Surg; 1989 Mar; 47(3):352-61. PubMed ID: 2930300
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Twenty-six-year durability of an Ionescu-Shiley standard profile pericardial aortic valve.
    Honda K; Okamura Y; Nishimura Y; Uchita S
    Interact Cardiovasc Thorac Surg; 2010 Feb; 10(2):315-6. PubMed ID: 19914926
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mode of failure of the Mitroflow pericardial valve.
    Leandri J; Bertrand P; Mazzucotelli JP; Loisance D
    J Heart Valve Dis; 1992 Nov; 1(2):225-31. PubMed ID: 1341633
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Reoperation for malfunction of Ionescu-Shiley bovine pericardial bioprosthetic valves in the mitral position--special consideration with emergency operation].
    Abe M; Sakai A; Hanayama N; Lin ZB; Oosawa M
    Nihon Kyobu Geka Gakkai Zasshi; 1997 Jan; 45(1):17-22. PubMed ID: 9028118
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ionescu-Shiley bovine pericardial bioprostheses. Histologic and ultrastructural studies.
    Hilbert SL; Ferrans VJ; McAllister HA; Cooley DA
    Am J Pathol; 1992 May; 140(5):1195-204. PubMed ID: 1580331
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Unusual 25-year durability of an Ionescu-Shiley pericardial bioprosthesis.
    Fiore A; Cooley DA; Grande AM; Viganò M; Angelini P
    Ann Thorac Surg; 2011 Apr; 91(4):e52-3. PubMed ID: 21440107
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Non-invasive assessment by Doppler ultrasound of 155 patients with bioprosthetic valves: a comparison of the Wessex porcine, low profile Ionescu-Shiley, and Hancock pericardial bioprostheses.
    Simpson IA; Reece IJ; Houston AB; Hutton I; Wheatley DJ; Cobbe SM
    Br Heart J; 1986 Jul; 56(1):83-8. PubMed ID: 3524634
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The Mitroflow pericardial valve: clinical performance to 10 years.
    Mazzucotelli JP; Bertrand PC; Loisance DY
    J Heart Valve Dis; 1995 Jul; 4(4):407-13. PubMed ID: 7582152
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Long term clinical and haemodynamic evaluation of the Ionescu-Shiley pericardial xenograft heart valve.
    Ionescu MI; Tandon AP
    Thoraxchir Vask Chir; 1978 Aug; 26(4):250-8. PubMed ID: 694896
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pericardial heterografts: why do these valves fail?
    Trowbridge EA; Lawford PV; Crofts CE; Roberts KM
    J Thorac Cardiovasc Surg; 1988 Apr; 95(4):577-85. PubMed ID: 3352291
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Failure mode of a new pericardial valve prosthesis (Sorin Pericarbon). A morphological study.
    Grabenwöger M; Grimm M; Leukauf C; Szeles C; Feichtinger E; Müller MM; Moritz A; Böck P; Wolner E
    Eur J Cardiothorac Surg; 1994; 8(9):470-6. PubMed ID: 7811479
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.