These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
133 related articles for article (PubMed ID: 36219496)
1. Effect of intensive insulin therapy on inflammatory response after cardiac surgery using bedside artificial pancreas: A propensity score-matched analysis. Fujii T; Hirai T; Tamura T; Suzuki S; Nishiwaki K Artif Organs; 2023 Jun; 47(6):982-989. PubMed ID: 36219496 [TBL] [Abstract][Full Text] [Related]
2. Surgical Site Infections and Inflammatory Reaction After Cardiac Surgery; Bedside Artificial Pancreas Versus Conventional Insulin Therapy: A Propensity Score-Matched Analysis. Fujii T; Hirai T; Suzuki S; Nishiwaki K J Cardiothorac Vasc Anesth; 2022 Mar; 36(3):840-846. PubMed ID: 34103216 [TBL] [Abstract][Full Text] [Related]
3. Utility of bedside artificial pancreas for postoperative glycemic control in cardiac surgery. Shin U; Naoko H; Michinori T; Yuya K; Yuka S; Yuki N; Motoharu K; Soichiro H; Mitsuo K; Yu Y; Tokito K; Satoru K; Kazuki D; Tetsuya O; Hirohisa M; Nobuhiko M; Takeshi O J Artif Organs; 2021 Jun; 24(2):225-233. PubMed ID: 33155103 [TBL] [Abstract][Full Text] [Related]
4. Dynamic changes in insulin requirements with post-operative time using bedside artificial pancreas to maintain normoglycemia without hypoglycemia after cardiac surgery. Urai S; Hashimoto N; Takabe M; Kawashima M; Satake Y; Nishimoto Y; Kuroda M; Yamane Y; Doi K; Oue T; Murakami H; Mukohara N; Ohara T J Artif Organs; 2022 Mar; 25(1):72-81. PubMed ID: 34191199 [TBL] [Abstract][Full Text] [Related]
5. Glucose control using a closed-loop device decreases inflammation after cardiovascular surgery without increasing hypoglycemia risk. Tamura T; Yatabe T; Namikawa T; Hanazaki K; Yokoyama M J Artif Organs; 2019 Jun; 22(2):154-159. PubMed ID: 30456660 [TBL] [Abstract][Full Text] [Related]
6. Anti-inflammatory effects of perioperative intensive insulin therapy during cardiac surgery with cardiopulmonary bypass. Hasegawa A; Iwasaka H; Hagiwara S; Koga H; Hasegawa R; Kudo K; Kusaka J; Noguchi T Surg Today; 2011 Oct; 41(10):1385-90. PubMed ID: 21922361 [TBL] [Abstract][Full Text] [Related]
7. Perioperative intensive insulin therapy using an artificial endocrine pancreas with closed-loop glycemic control system: the effects of no hypoglycemia. Hanazaki K; Kitagawa H; Yatabe T; Munekage M; Dabanaka K; Takezaki Y; Tsukamoto Y; Asano T; Kinoshita Y; Namikawa T Am J Surg; 2014 Jun; 207(6):935-41. PubMed ID: 24480234 [TBL] [Abstract][Full Text] [Related]
8. Comparison between a novel and conventional artificial pancreas for perioperative glycemic control using a closed-loop system. Namikawa T; Munekage M; Kitagawa H; Yatabe T; Maeda H; Tsukamoto Y; Hirano K; Asano T; Kinoshita Y; Hanazaki K J Artif Organs; 2017 Mar; 20(1):84-90. PubMed ID: 27651347 [TBL] [Abstract][Full Text] [Related]
9. Current topics in glycemic control by wearable artificial pancreas or bedside artificial pancreas with closed-loop system. Hanazaki K; Munekage M; Kitagawa H; Yatabe T; Munekage E; Shiga M; Maeda H; Namikawa T J Artif Organs; 2016 Sep; 19(3):209-18. PubMed ID: 27142278 [TBL] [Abstract][Full Text] [Related]
10. Perioperative tight glycemic control using artificial pancreas decreases infectious complications via suppression of inflammatory cytokines in patients who underwent pancreaticoduodenectomy: A prospective, non-randomized clinical trial. Akabori H; Tani M; Kitamura N; Maehira H; Imashuku Y; Tsujita Y; Shimizu T; Kitagawa H; Eguchi Y Am J Surg; 2020 Aug; 220(2):365-371. PubMed ID: 31836178 [TBL] [Abstract][Full Text] [Related]
11. What is the optimal range of glycemic control for non-diabetic patients undergoing gastroenterological surgery? A single-center randomized controlled trial using an artificial pancreas. Tanioka N; Maeda H; Uemura S; Munekage M; Kitagawa H; Namikawa T; Kuroiwa H; Fujimoto S; Seo S; Hanazaki K Artif Organs; 2023 Jun; 47(6):943-950. PubMed ID: 37084125 [TBL] [Abstract][Full Text] [Related]
12. Continuous postoperative blood glucose monitoring and control by artificial pancreas in patients having pancreatic resection: a prospective randomized clinical trial. Okabayashi T; Nishimori I; Yamashita K; Sugimoto T; Maeda H; Yatabe T; Kohsaki T; Kobayashi M; Hanazaki K Arch Surg; 2009 Oct; 144(10):933-7. PubMed ID: 19841361 [TBL] [Abstract][Full Text] [Related]
13. Intensive intraoperative insulin therapy versus conventional glucose management during cardiac surgery: a randomized trial. Gandhi GY; Nuttall GA; Abel MD; Mullany CJ; Schaff HV; O'Brien PC; Johnson MG; Williams AR; Cutshall SM; Mundy LM; Rizza RA; McMahon MM Ann Intern Med; 2007 Feb; 146(4):233-43. PubMed ID: 17310047 [TBL] [Abstract][Full Text] [Related]
14. Tight perioperative glycemic control using an artificial endocrine pancreas. Hanazaki K; Maeda H; Okabayashi T Surg Today; 2010; 40(1):1-7. PubMed ID: 20037833 [TBL] [Abstract][Full Text] [Related]
15. Comparison of glycemic and surgical outcomes after change in glycemic targets in cardiac surgery patients. Mulla I; Schmidt K; Cashy J; Wallia A; Andrei AC; Johnson Oakes D; Aleppo G; Li C; Grady KL; McGee E; Molitch ME Diabetes Care; 2014 Nov; 37(11):2960-5. PubMed ID: 25193527 [TBL] [Abstract][Full Text] [Related]
16. Dynamic tight glycemic control during and after cardiac surgery is effective, feasible, and safe. Lecomte P; Foubert L; Nobels F; Coddens J; Nollet G; Casselman F; Crombrugge PV; Vandenbroucke G; Cammu G Anesth Analg; 2008 Jul; 107(1):51-8. PubMed ID: 18635467 [TBL] [Abstract][Full Text] [Related]
17. Design and rationale of safe pediatric euglycemia after cardiac surgery: a randomized controlled trial of tight glycemic control after pediatric cardiac surgery. Gaies MG; Langer M; Alexander J; Steil GM; Ware J; Wypij D; Laussen PC; Newburger JW; Goldberg CS; Pigula FA; Shukla AC; Duggan CP; Agus MS; Pediatr Crit Care Med; 2013 Feb; 14(2):148-56. PubMed ID: 22805161 [TBL] [Abstract][Full Text] [Related]
18. Closed-loop artificial endocrine pancreas from Japan. Hanazaki K; Tanioka N; Munekage M; Uemura S; Maeda H Artif Organs; 2021 Sep; 45(9):958-967. PubMed ID: 34105784 [TBL] [Abstract][Full Text] [Related]
19. Analysis of perioperative glucose metabolism using an artificial pancreas. Okazaki M; Hayashi H; Gabata R; Ohbatake Y; Shinbashi H; Nakanuma S; Makino I; Tajima H; Takamura H; Ohta T Artif Organs; 2021 Sep; 45(9):998-1005. PubMed ID: 33819346 [TBL] [Abstract][Full Text] [Related]
20. Tight perioperative glucose control is associated with a reduction in renal impairment and renal failure in non-diabetic cardiac surgical patients. Lecomte P; Van Vlem B; Coddens J; Cammu G; Nollet G; Nobels F; Vanermen H; Foubert L Crit Care; 2008; 12(6):R154. PubMed ID: 19055829 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]