These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

181 related articles for article (PubMed ID: 36220193)

  • 1. Noninvasive Ventilation Automated Technologies: A Bench Evaluation of Device Responses to Sleep-Related Respiratory Events.
    Delorme M; Leroux K; Leotard A; Boussaid G; Prigent H; Louis B; Lofaso F
    Respir Care; 2023 Jan; 68(1):18-30. PubMed ID: 36220193
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Best clinical practices for the sleep center adjustment of noninvasive positive pressure ventilation (NPPV) in stable chronic alveolar hypoventilation syndromes.
    Berry RB; Chediak A; Brown LK; Finder J; Gozal D; Iber C; Kushida CA; Morgenthaler T; Rowley JA; Davidson-Ward SL;
    J Clin Sleep Med; 2010 Oct; 6(5):491-509. PubMed ID: 20957853
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Treating Chronic Hypoventilation With Automatic Adjustable Versus Fixed EPAP Intelligent Volume-Assured Positive Airway Pressure Support (iVAPS): A Randomized Controlled Trial.
    McArdle N; Rea C; King S; Maddison K; Ramanan D; Ketheeswaran S; Erikli L; Baker V; Armitstead J; Richards G; Singh B; Hillman D; Eastwood P
    Sleep; 2017 Oct; 40(10):. PubMed ID: 28958052
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Automatic EPAP intelligent volume-assured pressure support is effective in patients with chronic respiratory failure: A randomized trial.
    Orr JE; Coleman J; Criner GJ; Sundar KM; Tsai SC; Benjafield AV; Crocker ME; Willes L; Malhotra A; Owens RL; Wolfe LF
    Respirology; 2019 Dec; 24(12):1204-1211. PubMed ID: 31012225
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Sleep related respiratory events during non-invasive ventilation of patients with chronic hypoventilation.
    Aarrestad S; Qvarfort M; Kleiven AL; Tollefsen E; Skjønsberg OH; Janssens JP
    Respir Med; 2017 Nov; 132():210-216. PubMed ID: 29229100
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison between auto-trilevel and bilevel positive airway pressure ventilation for treatment of patients with concurrent obesity hypoventilation syndrome and obstructive sleep apnea syndrome.
    Zou C; Sheng W; Huai D; Cao J; Su M; Ning D; Xue R; Wang Y; Huang M; Zhang X
    Sleep Breath; 2019 Sep; 23(3):735-740. PubMed ID: 30426457
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Volume-targeted pressure support and automatic EPAP for chronic hypoventilation syndromes: An advance in-home ventilation or just more noise?
    McArdle N
    Respirology; 2019 Oct; 24(10):944-951. PubMed ID: 30575208
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical guidelines for the manual titration of positive airway pressure in patients with obstructive sleep apnea.
    Kushida CA; Chediak A; Berry RB; Brown LK; Gozal D; Iber C; Parthasarathy S; Quan SF; Rowley JA; ;
    J Clin Sleep Med; 2008 Apr; 4(2):157-71. PubMed ID: 18468315
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Rules for scoring respiratory events in sleep: update of the 2007 AASM Manual for the Scoring of Sleep and Associated Events. Deliberations of the Sleep Apnea Definitions Task Force of the American Academy of Sleep Medicine.
    Berry RB; Budhiraja R; Gottlieb DJ; Gozal D; Iber C; Kapur VK; Marcus CL; Mehra R; Parthasarathy S; Quan SF; Redline S; Strohl KP; Davidson Ward SL; Tangredi MM;
    J Clin Sleep Med; 2012 Oct; 8(5):597-619. PubMed ID: 23066376
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Bench test evaluation of adaptive servoventilation devices for sleep apnea treatment.
    Zhu K; Kharboutly H; Ma J; Bouzit M; Escourrou P
    J Clin Sleep Med; 2013 Sep; 9(9):861-71. PubMed ID: 23997698
    [TBL] [Abstract][Full Text] [Related]  

  • 11. All APAPs Are Not Equivalent for the Treatment of Sleep Disordered Breathing: A Bench Evaluation of Eleven Commercially Available Devices.
    Zhu K; Roisman G; Aouf S; Escourrou P
    J Clin Sleep Med; 2015 Jul; 11(7):725-34. PubMed ID: 25766708
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reliability of Apnea-Hypopnea Index Measured by a Home Bi-Level Pressure Support Ventilator Versus a Polysomnographic Assessment.
    Georges M; Adler D; Contal O; Espa F; Perrig S; Pépin JL; Janssens JP
    Respir Care; 2015 Jul; 60(7):1051-6. PubMed ID: 25737571
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Impact of Unintentional Air Leaks on Automatic Positive Airway Pressure Device Performance in Simulated Sleep Apnea Events.
    Fasquel L; Yazdani P; Zaugg C; Barras A; Michotte JB; Correvon N; Contal O
    Respir Care; 2023 Jan; 68(1):31-37. PubMed ID: 36347566
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Randomized trial of 'intelligent' autotitrating ventilation versus standard pressure support non-invasive ventilation: impact on adherence and physiological outcomes.
    Kelly JL; Jaye J; Pickersgill RE; Chatwin M; Morrell MJ; Simonds AK
    Respirology; 2014 May; 19(4):596-603. PubMed ID: 24661390
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Sleep and respiratory function after withdrawal of noninvasive ventilation in patients with chronic respiratory failure.
    Petitjean T; Philit F; Germain-Pastenne M; Langevin B; Guérin C
    Respir Care; 2008 Oct; 53(10):1316-23. PubMed ID: 18811993
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Detection of upper airway status and respiratory events by a current generation positive airway pressure device.
    Li QY; Berry RB; Goetting MG; Staley B; Soto-Calderon H; Tsai SC; Jasko JG; Pack AI; Kuna ST
    Sleep; 2015 Apr; 38(4):597-605. PubMed ID: 25409101
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Paradoxical worsening of hypoxemia in a patient treated by noninvasive positive pressure ventilation for obesity hypoventilation syndrome with concomitant obstructive sleep apnea: a case report.
    de Picciotto C; Duménil C; Auzel O; Giraud V; Bonay M
    J Med Case Rep; 2017 Aug; 11(1):234. PubMed ID: 28830548
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The performance of two automatic servo-ventilation devices in the treatment of central sleep apnea.
    Javaheri S; Goetting MG; Khayat R; Wylie PE; Goodwin JL; Parthasarathy S
    Sleep; 2011 Dec; 34(12):1693-8. PubMed ID: 22131607
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Patterns of adaptive servo-ventilation settings in a real-life multicenter study: pay attention to volume! : Adaptive servo-ventilation settings in real-life conditions.
    Jaffuel D; Rabec C; Philippe C; Mallet JP; Georges M; Redolfi S; Palot A; Suehs CM; Nogue E; Molinari N; Bourdin A
    Respir Res; 2020 Sep; 21(1):243. PubMed ID: 32957983
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Can fiberoptic bronchoscopy be applied to critically ill patients treated with noninvasive ventilation for acute respiratory distress syndrome? Prospective observational study.
    Korkmaz Ekren P; Basarik Aydogan B; Gurgun A; Tasbakan MS; Bacakoglu F; Nava S
    BMC Pulm Med; 2016 May; 16(1):89. PubMed ID: 27245054
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.