BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 36227247)

  • 1. Techniques for Safe Removal of Spinal Cord Stimulation Paddle Leads.
    Topp G; Harland T; Spurgas M; Rock A; Pilitsis JG
    Oper Neurosurg (Hagerstown); 2022 Dec; 23(6):e348-e352. PubMed ID: 36227247
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Rate of Complications Following Spinal Cord Stimulation Paddle Electrode Removal.
    Maldonado-Naranjo AL; Frizon LA; Sabharwal NC; Xiao R; Hogue O; Lobel DA; Machado AG; Nagel SJ
    Neuromodulation; 2018 Jul; 21(5):513-519. PubMed ID: 28833931
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Revision and Replacement of Spinal Cord Stimulator Paddle Leads.
    Harland TA; Topp G; Shao K; Pilitsis JG
    Neuromodulation; 2022 Jul; 25(5):753-757. PubMed ID: 35393239
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of Clinical Efficacy and Computed Tomographic Analysis of Lead Position Between Three-Column and Five-Column Paddle Leads Spinal Cord Stimulation for Failed Back Surgery Syndrome.
    Choi JG; Ha SW; Son BC
    World Neurosurg; 2017 Jan; 97():292-303. PubMed ID: 27744081
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Long-term outcomes of spinal cord stimulation with paddle leads in the treatment of complex regional pain syndrome and failed back surgery syndrome.
    Sears NC; Machado AG; Nagel SJ; Deogaonkar M; Stanton-Hicks M; Rezai AR; Henderson JM
    Neuromodulation; 2011; 14(4):312-8; discussion 318. PubMed ID: 21992424
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Retrograde thoracic spinal cord stimulation paddle placement for complex persistent spinal pain syndrome type 2.
    de Monaco BA; Piedade GS; Doomi A; Jagid JR; Almeida T; Cordeiro JG
    Pain Pract; 2024 Mar; 24(3):483-488. PubMed ID: 38041599
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Surgical Paddle Electrode Implantation as a Rescue Therapy to Failed Percutaneous Leads in Failed Back Surgery Syndrome Patients.
    Witkam RL; Buijse ML; Arnts IJJ; Henssen DJHA; Vissers KCP; van Dongen R; Kurt E
    Neuromodulation; 2022 Jul; 25(5):745-752. PubMed ID: 35227584
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Minimally Invasive Placement of Spinal Cord Stimulator Paddle Electrodes Is Associated With Improved Perioperative and Long-Term Experience Among Neuropathic Pain Patients.
    Shamji MF; Paul D; Mednikov A
    Spine (Phila Pa 1976); 2018 Mar; 43(5):324-330. PubMed ID: 27997509
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Spinal Cord Stimulator Paddle Lead Revision and Replacement for Misplaced or Displaced Electrodes.
    Mong ER; Kethireddy S; Staudt MD
    World Neurosurg; 2024 Jun; 186():e432-e439. PubMed ID: 38561030
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Compression of Thoracic Spinal Cord with Decreased Cerebrospinal Fluid Space After Implantation of Paddle Lead Spinal Cord Stimulation at T9: A Three-Dimensional Myelographic Computed Tomography Study.
    Son BC; Ko HC; Choi JG
    World Neurosurg; 2018 Oct; 118():e323-e334. PubMed ID: 29969740
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Open Paddle Lead Trial for Spinal Cord Stimulation: An Institutional Experience.
    Akbik OS; Aoun SG; Adogwa O; Bagley CA; Al Tamimi M
    Pain Physician; 2022 Jan; 25(1):E37-E42. PubMed ID: 35051150
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Preoperative Thoracic Spine Magnetic Resonance Imaging for Spinal Cord Stimulation: Should Such a Recommendation Be an Absolute Requirement?
    Best BJ; Porwal MH; Pahapill PA
    Neuromodulation; 2022 Jul; 25(5):758-762. PubMed ID: 35803680
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The Role of Additional Spine Surgery in the Management of Failed Back Surgery Syndrome, Complex Regional Pain Syndrome, and Intractable Pain in the Setting of Previous or Concurrent Spinal Cord Stimulation: Indications and Outcomes.
    Maldonado-Naranjo AL; Golubovsky JL; Frizon LA; Hogue O; Lobel DA; Machado AG; Steinmetz MP; Nagel SJ
    World Neurosurg; 2019 May; 125():e416-e423. PubMed ID: 30703586
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Immediate Abdominal Pain after Placement of Thoracic Paddle Leads for Spinal Cord Stimulation: A Case Series.
    Lee JJ; Sadrameli SS; Desai VR; Austerman RJ; Leonard DM; Dalm BD
    Stereotact Funct Neurosurg; 2018; 96(6):400-405. PubMed ID: 30605913
    [TBL] [Abstract][Full Text] [Related]  

  • 15. New technique for open placement of paddle-type spinal cord stimulator electrode in presence of epidural scar tissue.
    Pabaney AH; Robin AM; Schwalb JM
    Neuromodulation; 2014 Dec; 17(8):759-62; discussion 762. PubMed ID: 24725098
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A Novel Nonanchoring Technique for Implantation of Paddle Leads in the Cervical Spine Under Conscious Sedation.
    Pahapill PA
    Neuromodulation; 2015 Aug; 18(6):472-6; discussion 476-7. PubMed ID: 25809094
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Electrophysiologic monitoring for placement of laminectomy leads for spinal cord stimulation under general anesthesia.
    Air EL; Toczyl GR; Mandybur GT
    Neuromodulation; 2012; 15(6):573-9; discussion 579-80. PubMed ID: 23205816
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Analysis of spinal canal diameter in the placement of thoracic spinal cord stimulator paddle leads.
    Ragel BT; Riedman T; McGehee M; Raslan AM
    Pain Pract; 2024 Jan; 24(1):91-100. PubMed ID: 37626446
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Altering Conventional to High Density Spinal Cord Stimulation: An Energy Dose-Response Relationship in Neuropathic Pain Therapy.
    Wille F; Breel JS; Bakker EW; Hollmann MW
    Neuromodulation; 2017 Jan; 20(1):71-80. PubMed ID: 27778413
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Spinal Cord Stimulation Paddle-to-Percutaneous Revision: Case Series and Technical Description.
    Staudt MD
    World Neurosurg; 2024 Feb; 182():e891-e898. PubMed ID: 38128757
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.