264 related articles for article (PubMed ID: 36228451)
1. Isotope-dilution liquid chromatography-tandem mass spectrometry method for serum beta 2-microglobulin quantification.
Yang S; Tian X; Chen Y; Shen L; Wang J
J Chromatogr B Analyt Technol Biomed Life Sci; 2022 Nov; 1211():123487. PubMed ID: 36228451
[TBL] [Abstract][Full Text] [Related]
2. Quantification of cystatin-C in human serum by stable isotope dilution liquid chromatography electrospray ionization tandem mass spectrometry.
Ji H; Wang J; Ju S; Cong H; Wang X; Su J; Wang H
J Chromatogr B Analyt Technol Biomed Life Sci; 2017 Aug; 1059():49-55. PubMed ID: 28578261
[TBL] [Abstract][Full Text] [Related]
3. Automated isotope dilution liquid chromatography-tandem mass spectrometry with on-line dilution and solid phase extraction for the measurement of cortisol in human serum sample.
Kawaguchi M; Eyama S; Takatsu A
J Pharm Biomed Anal; 2014 Aug; 96():220-3. PubMed ID: 24769301
[TBL] [Abstract][Full Text] [Related]
4. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of methotrexate in human serum and plasma.
Engel A; Ruhe L; Singh N; Wright JA; Liesch F; Bauland F; Ostermann AI; Sumalowitsch T; Schweinsberg VJT; Geistanger A; Hegel JK; Geletneky C; Taibon J
Clin Chem Lab Med; 2023 Oct; 61(11):1917-1929. PubMed ID: 36788118
[TBL] [Abstract][Full Text] [Related]
5. Towards absolute quantification of therapeutic monoclonal antibody in serum by LC-MS/MS using isotope-labeled antibody standard and protein cleavage isotope dilution mass spectrometry.
Heudi O; Barteau S; Zimmer D; Schmidt J; Bill K; Lehmann N; Bauer C; Kretz O
Anal Chem; 2008 Jun; 80(11):4200-7. PubMed ID: 18465883
[TBL] [Abstract][Full Text] [Related]
6. Measurement of human serum unconjugated estriol without derivatization using liquid chromatography-tandem mass spectrometry candidate reference method and compared with two immunoassays.
Huang X; Zhang Q; Zheng S; Wang J; Han L; Lin H; Ke P; Zhuang J; Cao ZT
Anal Bioanal Chem; 2018 Sep; 410(24):6257-6267. PubMed ID: 30006726
[TBL] [Abstract][Full Text] [Related]
7. State-of-the-art of serum testosterone measurement by isotope dilution-liquid chromatography-tandem mass spectrometry.
Thienpont LM; Van Uytfanghe K; Blincko S; Ramsay CS; Xie H; Doss RC; Keevil BG; Owen LJ; Rockwood AL; Kushnir MM; Chun KY; Chandler DW; Field HP; Sluss PM
Clin Chem; 2008 Aug; 54(8):1290-7. PubMed ID: 18556330
[TBL] [Abstract][Full Text] [Related]
8. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of aldosterone in human serum and plasma.
Taibon J; Santner T; Singh N; Ibrahim SC; Babitzki G; Köppl D; Gaudl A; Geistanger A; Ceglarek U; Rauh M; Geletneky C
Clin Chem Lab Med; 2023 Oct; 61(11):1902-1916. PubMed ID: 36952682
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of a bracketing calibration-based isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for 17α-hydroxyprogesterone in human plasma.
Zhang Q; Zhang L; Lin H; Cai Z; Yan J; Wang Q; Han L; Wang J; Ke P; Zhuang J; Huang X
Anal Bioanal Chem; 2019 Nov; 411(27):7095-7104. PubMed ID: 31673753
[TBL] [Abstract][Full Text] [Related]
10. Isotope-dilution liquid chromatography-tandem mass spectrometry for quantification of human retinol binding protein 4 in serum.
Tian X; Yang S; Tang Q; Ji H; Shen L; Wang J
Anal Biochem; 2022 May; 645():114589. PubMed ID: 35167820
[TBL] [Abstract][Full Text] [Related]
11. Quantitation of plasma metanephrines using isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS): a candidate reference measurement procedure and its application to evaluating routine ID-LC/MS/MS methods.
Liu Z; Liu Q; Deng Y; Zhao H; Zeng J; Zhang T; Zhang J; Wang J; Zhou W; Zhang C
Anal Bioanal Chem; 2021 Dec; 413(30):7509-7520. PubMed ID: 34643770
[TBL] [Abstract][Full Text] [Related]
12. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of levetiracetam in human serum and plasma.
Kobel A; Schierscher T; Singh N; Salzmann L; Liesch F; Bauland F; Geistanger A; Risch L; Geletneky C; Seger C; Taibon J
Clin Chem Lab Med; 2023 Oct; 61(11):1967-1977. PubMed ID: 37011038
[TBL] [Abstract][Full Text] [Related]
13. LC-MS/MS determination of a human mAb drug candidate in rat serum using an isotopically labeled universal mAb internal standard.
Li W; Lin H; Fu Y; Flarakos J
J Chromatogr B Analyt Technol Biomed Life Sci; 2017 Feb; 1044-1045():166-176. PubMed ID: 28113139
[TBL] [Abstract][Full Text] [Related]
14. Development of an antibody-free ID-LC MS method for the quantification of procalcitonin in human serum at sub-microgram per liter level using a peptide-based calibration.
Huynh HH; Bœuf A; Derbez-Morin M; Dupuy AM; Lalere B; Delatour V; Vinh J
Anal Bioanal Chem; 2021 Aug; 413(19):4707-4725. PubMed ID: 33987701
[TBL] [Abstract][Full Text] [Related]
15. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of gabapentin in human serum and plasma.
Salzmann L; Wild J; Singh N; Schierscher T; Liesch F; Bauland F; Geistanger A; Risch L; Geletneky C; Seger C; Taibon J
Clin Chem Lab Med; 2023 Oct; 61(11):1955-1966. PubMed ID: 36689915
[TBL] [Abstract][Full Text] [Related]
16. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of carbamazepine in human serum and plasma.
Schierscher T; Salzmann L; Singh N; Bachmann M; Bauland F; Geistanger A; Risch L; Geletneky C; Seger C; Taibon J
Clin Chem Lab Med; 2024 Jun; 62(7):1301-1313. PubMed ID: 38095314
[TBL] [Abstract][Full Text] [Related]
17. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of lamotrigine in human serum and plasma.
Salzmann L; Spescha T; Singh N; Schierscher T; Bachmann M; Bauland F; Geistanger A; Risch L; Geletneky C; Seger C; Taibon J
Clin Chem Lab Med; 2023 Oct; 61(11):1930-1941. PubMed ID: 36785916
[TBL] [Abstract][Full Text] [Related]
18. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure for the quantification of carbamazepine-10,11-epoxide in human serum and plasma.
Schierscher T; Singh N; Kobel A; Wild J; Bauland F; Geistanger A; Risch L; Geletneky C; Seger C; Taibon J
Clin Chem Lab Med; 2024 Jun; 62(7):1339-1351. PubMed ID: 38515344
[TBL] [Abstract][Full Text] [Related]
19. An Accurate Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry Method for Serum C-Peptide and Its Use in Harmonization in China.
Deng Y; Zhang C; Wang J; Zeng J; Zhang J; Zhang T; Zhao H; Zhou W; Zhang C
Ann Lab Med; 2023 Jul; 43(4):345-354. PubMed ID: 36843403
[TBL] [Abstract][Full Text] [Related]
20. Quantification of cardiac troponin I in human plasma by immunoaffinity enrichment and targeted mass spectrometry.
Schneck NA; Phinney KW; Lee SB; Lowenthal MS
Anal Bioanal Chem; 2018 Apr; 410(11):2805-2813. PubMed ID: 29492621
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]