These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 36236876)

  • 1. High-stability PGC demodulation technique with an additional sinusoidal modulation based on an auxiliary reference interferometer and EFA.
    Mu S; Yu B; Gui L; Shi J; Guang D; Zuo C; Zhang W; Zhao X; Wu X
    Opt Express; 2022 Jul; 30(15):26941-26954. PubMed ID: 36236876
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Phase noise suppression technique based on an improved reference interferometer scheme.
    Zhou W; Yu B; Zhang J; Shi J; Guang D; Zuo C; Mu S; Fang C; Zhang D; Lin J; Wu X
    Opt Express; 2023 Oct; 31(21):33765-33775. PubMed ID: 37859149
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Self-calibration phase demodulation scheme for stabilization based on an auxiliary reference fiber-optic interferometer and ellipse fitting algorithm.
    Wu Y; Li C; Wang C; Jia B
    Opt Express; 2023 Jan; 31(3):4639-4651. PubMed ID: 36785426
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Real-time normalization and nonlinearity evaluation methods of the PGC-arctan demodulation in an EOM-based sinusoidal phase modulating interferometer.
    Zhang S; Chen B; Yan L; Xu Z
    Opt Express; 2018 Jan; 26(2):605-616. PubMed ID: 29401943
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Precision PGC demodulation for homodyne interferometer modulated with a combined sinusoidal and triangular signal.
    Yan L; Chen Z; Chen B; Xie J; Zhang S; Lou Y; Zhang E
    Opt Express; 2018 Feb; 26(4):4818-4831. PubMed ID: 29475326
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Improved PGC demodulation algorithm to eliminate modulation depth and intensity disturbance.
    Li Y; Gao H; Zhao L; Fu Z; Zhang J; Li Z; Qiao X
    Appl Opt; 2022 Jul; 61(19):5722-5727. PubMed ID: 36255804
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Distortion-corrected phase demodulation using phase-generated carrier with multitone mixing.
    Marin Y; Velha P; Oton CJ
    Opt Express; 2020 Nov; 28(24):36849-36861. PubMed ID: 33379769
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Real-Time Measurement and Uncertainty Evaluation of Optical Path Difference in Fiber Optic Interferometer Based on Auxiliary Interferometer.
    Li H; Lou M; Huang W; Zhang W
    Sensors (Basel); 2024 Mar; 24(7):. PubMed ID: 38610250
    [TBL] [Abstract][Full Text] [Related]  

  • 9. High precision 3 × 3 coupler demodulation algorithm with an additional phase shift judgment module.
    Pan S; Ge Q; Zhang G; Xiao J; Xu D; Yu B
    Appl Opt; 2024 May; 63(13):3695-3701. PubMed ID: 38856556
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Real-time self-calibration PGC-Arctan demodulation algorithm in fiber-optic interferometric sensors.
    Qu Z; Guo S; Hou C; Yang J; Yuan L
    Opt Express; 2019 Aug; 27(16):23593-23609. PubMed ID: 31510634
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Phase-shifted demodulation technique with additional modulation based on a 3 × 3 coupler and EFA for the interrogation of fiber-optic interferometric sensors.
    Shi J; Guang D; Li S; Wu X; Zhang G; Zuo C; Zhang G; Wang R; Ge Q; Yu B
    Opt Lett; 2021 Jun; 46(12):2900-2903. PubMed ID: 34129569
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sinusoidal phase-modulating interferometer with ellipse fitting and a correction method.
    Ni C; Zhang M; Zhu Y; Hu C; Ding S; Jia Z
    Appl Opt; 2017 May; 56(13):3895-3899. PubMed ID: 28463284
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ameliorated PGC demodulation technique based on the ODR algorithm with insensitivity to phase modulation depth.
    Zhou W; Yu B; Zhang J; Shi J; Guang D; Zuo C; Mu S; Liu Y; Lin Z; Wu X
    Opt Express; 2023 Feb; 31(5):7175-7186. PubMed ID: 36859854
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Sinusoidal Phase-Modulated Angle Interferometer for Angular Vibration Measurement.
    Wang X; Yang J; Chen M; Miao L; Huang T
    Sensors (Basel); 2021 Sep; 21(18):. PubMed ID: 34577502
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Direct nonlinear parameter estimation method for a phase generated carrier position sensor.
    Zhao H; Xu Z; Ma D
    Opt Express; 2023 Jul; 31(15):24702-24716. PubMed ID: 37475290
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Real-time phase delay compensation of PGC demodulation in sinusoidal phase-modulation interferometer for nanometer displacement measurement.
    Zhang S; Yan L; Chen B; Xu Z; Xie J
    Opt Express; 2017 Jan; 25(1):472-485. PubMed ID: 28085841
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Correction of nonlinear errors from PGC carrier phase delay and AOIM in fiber-optic interferometers for nanoscale displacement measurement.
    Dong Y; Hu P; Ran M; Fu H; Yang H; Yang R
    Opt Express; 2020 Jan; 28(2):2611-2624. PubMed ID: 32121946
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Optimization of the phase generated carrier demodulation algorithm based on support vector regression.
    Ma H; Li B; Xue M; Zhao W; Wei S; Bian Z; Chu F
    Appl Opt; 2021 Nov; 60(31):9818-9827. PubMed ID: 34807169
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Absolute distance measurement using sinusoidal phase modulating frequency sweeping interferometry with a reference interferometer.
    Zhang S; Shan D; Jin H; Lou Y; Yan L; Chen B
    Opt Express; 2022 Oct; 30(21):38880-38895. PubMed ID: 36258442
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Improved PGC demodulation algorithm for fiber optic interferometric sensors.
    Zhu M; Wang X; Chang J; Zhou H
    Opt Express; 2024 Jan; 32(2):2162-2178. PubMed ID: 38297752
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.