These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
184 related articles for article (PubMed ID: 36243630)
1. PEEP titration by EIT strategies for patients with ARDS: A systematic review and meta-analysis. Yu M; Deng Y; Cha J; Jiang L; Wang M; Qiao S; Wang C Med Intensiva (Engl Ed); 2023 Jul; 47(7):383-390. PubMed ID: 36243630 [TBL] [Abstract][Full Text] [Related]
2. Effect of EIT-guided PEEP titration on prognosis of patients with moderate to severe ARDS: study protocol for a multicenter randomized controlled trial. Yuan X; Zhang R; Wang Y; Chen D; Chao Y; Xu J; Guo L; Liu A; Xie J; Pan C; Yang Y; Qiu H; Liu L Trials; 2023 Apr; 24(1):266. PubMed ID: 37041561 [TBL] [Abstract][Full Text] [Related]
3. Electrical impedance tomography-guided positive end-expiratory pressure titration in ARDS: a systematic review and meta-analysis. Songsangvorn N; Xu Y; Lu C; Rotstein O; Brochard L; Slutsky AS; Burns KEA; Zhang H Intensive Care Med; 2024 May; 50(5):617-631. PubMed ID: 38512400 [TBL] [Abstract][Full Text] [Related]
4. Electrical impedance tomography for titration of positive end-expiratory pressure in acute respiratory distress syndrome patients with chronic obstructive pulmonary disease. Liu X; Liu X; Meng J; Liu D; Huang Y; Sang L; Xu Y; Xu Z; He W; Chen S; Zhang R; Liu X; Li Y Crit Care; 2022 Nov; 26(1):339. PubMed ID: 36333809 [TBL] [Abstract][Full Text] [Related]
5. Assessment of electrical impedance tomography to set optimal positive end-expiratory pressure for veno-venous ECMO-treated severe ARDS patients. Puel F; Crognier L; Soulé C; Vardon-Bounes F; Ruiz S; Seguin T; Fourcade O; Minville V; Conil JM; Georges B J Crit Care; 2020 Dec; 60():38-44. PubMed ID: 32736198 [TBL] [Abstract][Full Text] [Related]
6. Clinical implementation of electric impedance tomography in the treatment of ARDS: a single centre experience. Heines SJH; Strauch U; van de Poll MCG; Roekaerts PMHJ; Bergmans DCJJ J Clin Monit Comput; 2019 Apr; 33(2):291-300. PubMed ID: 29845479 [TBL] [Abstract][Full Text] [Related]
7. Early individualized positive end-expiratory pressure guided by electrical impedance tomography in acute respiratory distress syndrome: a randomized controlled clinical trial. He H; Chi Y; Yang Y; Yuan S; Long Y; Zhao P; Frerichs I; Fu F; Möller K; Zhao Z Crit Care; 2021 Jun; 25(1):230. PubMed ID: 34193224 [TBL] [Abstract][Full Text] [Related]
8. Electric impedance tomography-guided PEEP titration reduces mechanical power in ARDS: a randomized crossover pilot trial. Jimenez JV; Munroe E; Weirauch AJ; Fiorino K; Culter CA; Nelson K; Labaki WW; Choi PJ; Co I; Standiford TJ; Prescott HC; Hyzy RC Crit Care; 2023 Jan; 27(1):21. PubMed ID: 36650593 [TBL] [Abstract][Full Text] [Related]
9. Compliance-guided versus FiO Pintado MC; de Pablo R; Trascasa M; Milicua JM; Sánchez-García M Med Intensiva; 2017; 41(5):277-284. PubMed ID: 27776936 [TBL] [Abstract][Full Text] [Related]
10. Electrical impedance tomography: A compass for the safe route to optimal PEEP. Sella N; Pettenuzzo T; Zarantonello F; Andreatta G; De Cassai A; Schiavolin C; Simoni C; Pasin L; Boscolo A; Navalesi P Respir Med; 2021 Oct; 187():106555. PubMed ID: 34352563 [TBL] [Abstract][Full Text] [Related]
11. Positive end-expiratory pressure titration with electrical impedance tomography and pressure-volume curve in severe acute respiratory distress syndrome. Zhao Z; Chang MY; Chang MY; Gow CH; Zhang JH; Hsu YL; Frerichs I; Chang HT; Möller K Ann Intensive Care; 2019 Jan; 9(1):7. PubMed ID: 30656479 [TBL] [Abstract][Full Text] [Related]
12. Is EIT-guided positive end-expiratory pressure titration for optimizing PEEP in ARDS the white elephant in the room? A systematic review with meta-analysis and trial sequential analysis. Sarkar S; Yalla B; Khanna P; Baishya M J Clin Monit Comput; 2024 Aug; 38(4):873-883. PubMed ID: 38619718 [TBL] [Abstract][Full Text] [Related]
14. Relationship between lung ultrasound and electrical impedance tomography as regional assessment tools during PEEP titration in acute respiratory distress syndrome caused by multi-lobar pneumonia: a pilot study. Theerawit P; Pukapong P; Sutherasan Y J Clin Monit Comput; 2023 Jun; 37(3):889-897. PubMed ID: 36592267 [TBL] [Abstract][Full Text] [Related]
15. Bedside Contribution of Electrical Impedance Tomography to Setting Positive End-Expiratory Pressure for Extracorporeal Membrane Oxygenation-treated Patients with Severe Acute Respiratory Distress Syndrome. Franchineau G; Bréchot N; Lebreton G; Hekimian G; Nieszkowska A; Trouillet JL; Leprince P; Chastre J; Luyt CE; Combes A; Schmidt M Am J Respir Crit Care Med; 2017 Aug; 196(4):447-457. PubMed ID: 28103448 [TBL] [Abstract][Full Text] [Related]
16. Mechanical ventilation strategies for intensive care unit patients without acute lung injury or acute respiratory distress syndrome: a systematic review and network meta-analysis. Guo L; Wang W; Zhao N; Guo L; Chi C; Hou W; Wu A; Tong H; Wang Y; Wang C; Li E Crit Care; 2016 Jul; 20(1):226. PubMed ID: 27448995 [TBL] [Abstract][Full Text] [Related]
17. Effect of Titrating Positive End-Expiratory Pressure (PEEP) With an Esophageal Pressure-Guided Strategy vs an Empirical High PEEP-Fio2 Strategy on Death and Days Free From Mechanical Ventilation Among Patients With Acute Respiratory Distress Syndrome: A Randomized Clinical Trial. Beitler JR; Sarge T; Banner-Goodspeed VM; Gong MN; Cook D; Novack V; Loring SH; Talmor D; JAMA; 2019 Mar; 321(9):846-857. PubMed ID: 30776290 [TBL] [Abstract][Full Text] [Related]
18. Prognostic value of the novel P/FPE index to classify ARDS severity: A cohort study. Martos-Benítez FD; Estévez-Muguercia R; Orama-Requejo V; Del Toro-Simoni T Med Intensiva (Engl Ed); 2023 Jul; 47(7):373-382. PubMed ID: 36344340 [TBL] [Abstract][Full Text] [Related]
19. Electrical impedance tomography to titrate positive end-expiratory pressure in COVID-19 acute respiratory distress syndrome. Perier F; Tuffet S; Maraffi T; Alcala G; Victor M; Haudebourg AF; Razazi K; De Prost N; Amato M; Carteaux G; Mekontso Dessap A Crit Care; 2020 Dec; 24(1):678. PubMed ID: 33287864 [TBL] [Abstract][Full Text] [Related]
20. Dynamic Relative Regional Lung Strain Estimated by Electrical Impedance Tomography in an Experimental Model of ARDS. Gogniat E; Madorno M; Rodriguez PO; Dianti J; Otero PE; Krukewitt L; Böhm SH; Roman ES; Tusman G Respir Care; 2022 Aug; 67(8):906-913. PubMed ID: 35610029 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]