These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

228 related articles for article (PubMed ID: 36249475)

  • 1. Commercial smartwatch with pulse oximeter detects short-time hypoxemia as well as standard medical-grade device: Validation study.
    Rafl J; Bachman TE; Rafl-Huttova V; Walzel S; Rozanek M
    Digit Health; 2022; 8():20552076221132127. PubMed ID: 36249475
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of Leading Smartwatches for the Detection of Hypoxemia: Comparison to Reference Oximeter.
    Walzel S; Mikus R; Rafl-Huttova V; Rozanek M; Bachman TE; Rafl J
    Sensors (Basel); 2023 Nov; 23(22):. PubMed ID: 38005550
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Assessment of Non-Invasive Measurements of Oxygen Saturation and Heart Rate with an Apple Smartwatch: Comparison with a Standard Pulse Oximeter.
    Spaccarotella C; Polimeni A; Mancuso C; Pelaia G; Esposito G; Indolfi C
    J Clin Med; 2022 Mar; 11(6):. PubMed ID: 35329793
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Performance of a Wearable Ring in Controlled Hypoxia: A Prospective Observational Study.
    Mastrototaro JJ; Leabman M; Shumate J; Tompkins KL
    JMIR Form Res; 2024 Jun; 8():e54256. PubMed ID: 38838332
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Validation of the Withings ScanWatch as a Wrist-Worn Reflective Pulse Oximeter: Prospective Interventional Clinical Study.
    Kirszenblat R; Edouard P
    J Med Internet Res; 2021 Apr; 23(4):e27503. PubMed ID: 33857011
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Experiences of Patients With Chronic Obstructive Pulmonary Disease Using the Apple Watch Series 6 Versus the Traditional Finger Pulse Oximeter for Home SpO2 Self-Monitoring: Qualitative Study Part 2.
    Liu Y; Arnaert A; da Costa D; Sumbly P; Debe Z; Charbonneau S
    JMIR Aging; 2023 Nov; 6():e41539. PubMed ID: 37917147
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accuracy of the Apple Watch in measuring oxygen saturation: comparison with pulse oximetry and ABG.
    Arslan B; Sener K; Guven R; Kapci M; Korkut S; Sutasir MN; Tekindal MA
    Ir J Med Sci; 2024 Feb; 193(1):477-483. PubMed ID: 37440093
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy of pulse oximeters in detecting hypoxemia in patients with chronic thromboembolic pulmonary hypertension.
    Kohyama T; Moriyama K; Kanai R; Kotani M; Uzawa K; Satoh T; Yorozu T
    PLoS One; 2015; 10(5):e0126979. PubMed ID: 25978517
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia.
    Feiner JR; Bickler PE; Mannheimer PD
    Anesth Analg; 2010 Jul; 111(1):143-8. PubMed ID: 20007731
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Assessment of Noninvasive Oxygen Saturation in Patients With COPD During Pulmonary Rehabilitation: Smartwatch versus Pulse Oximeter.
    Støve MP; Graversen AH; Sørensen J
    Respir Care; 2023 Aug; 68(8):1041-1048. PubMed ID: 37193599
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Impacts of Skin Color and Hypoxemia on Noninvasive Assessment of Peripheral Blood Oxygen Saturation: A Scoping Review.
    Aoki KC; Barrant M; Gai MJ; Handal M; Xu V; Mayrovitz HN
    Cureus; 2023 Sep; 15(9):e46078. PubMed ID: 37900526
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Low Perfusion and Missed Diagnosis of Hypoxemia by Pulse Oximetry in Darkly Pigmented Skin: A Prospective Study.
    Gudelunas MK; Lipnick M; Hendrickson C; Vanderburg S; Okunlola B; Auchus I; Feiner JR; Bickler PE
    Anesth Analg; 2024 Mar; 138(3):552-561. PubMed ID: 38109495
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Experimental and clinical evaluation of a noninvasive reflectance pulse oximeter sensor.
    Takatani S; Davies C; Sakakibara N; Zurick A; Kraenzler E; Golding LR; Noon GP; Nose Y; DeBakey ME
    J Clin Monit; 1992 Oct; 8(4):257-66. PubMed ID: 1453185
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy and Reliability of Commercial Wrist-Worn Pulse Oximeter During Normobaric Hypoxia Exposure Under Resting Conditions.
    Lauterbach CJ; Romano PA; Greisler LA; Brindle RA; Ford KR; Kuennen MR
    Res Q Exerc Sport; 2021 Sep; 92(3):549-558. PubMed ID: 32633688
    [No Abstract]   [Full Text] [Related]  

  • 15. Technical note: a nose ring sensor system to monitor dairy cow cardiovascular and respiratory metrics.
    Salzer Y; Lidor G; Rosenfeld L; Reshef L; Shaked B; Grinshpun J; Honig HH; Kamer H; Balaklav M; Ross M
    J Anim Sci; 2022 Sep; 100(9):. PubMed ID: 35921498
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A Comparison of Finger Pulse Oximeter and SET-Based Neonatal Pulse Oximeter in Neonates in Terms of SpO
    Khamkar AM; Pote PD; Jose GE
    Indian J Pediatr; 2022 Nov; 89(11):1120-1122. PubMed ID: 35763217
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Design and evaluation of a new reflectance pulse oximeter sensor.
    Mendelson Y; Kent JC; Yocum BL; Birle MJ
    Med Instrum; 1988 Aug; 22(4):167-73. PubMed ID: 3173170
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of SpO
    Pipek LZ; Nascimento RFV; Acencio MMP; Teixeira LR
    Sci Rep; 2021 Sep; 11(1):18901. PubMed ID: 34556765
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Investigation of oesophageal photoplethysmographic signals and blood oxygen saturation measurements in cardiothoracic surgery patients.
    Kyriacou PA; Powell S; Langford RM; Jones DP
    Physiol Meas; 2002 Aug; 23(3):533-45. PubMed ID: 12214761
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accuracy of laminated disposable pulse-oximeter sensors.
    Russell GB; Graybeal JM
    Respir Care; 1995 Jul; 40(7):728-33. PubMed ID: 10144067
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]