133 related articles for article (PubMed ID: 36251283)
1. Generalization of an Open Dynamically Harmonized Cell for Ultrahigh FT ICR Resolution.
Lioznov A; Nikolaev E
J Am Soc Mass Spectrom; 2022 Nov; 33(11):2032-2037. PubMed ID: 36251283
[TBL] [Abstract][Full Text] [Related]
2. How to Increase Further the Resolving Power of the Ultrahigh Magnetic Field FT ICR Instruments? The New Concept of the FT ICR Cell-the Open Dynamically Harmonized Cell as a Part of the Vacuum System Wall.
Nikolaev E; Lioznov A
Anal Chem; 2021 Jan; 93(3):1249-1253. PubMed ID: 33352037
[TBL] [Abstract][Full Text] [Related]
3. FT-ICR Mass Spectrometry Imaging at Extreme Mass Resolving Power Using a Dynamically Harmonized ICR Cell with 1ω or 2ω Detection.
Tiquet M; La Rocca R; Kirnbauer S; Zoratto S; Van Kruining D; Quinton L; Eppe G; Martinez-Martinez P; Marchetti-Deschmann M; De Pauw E; Far J
Anal Chem; 2022 Jul; 94(26):9316-9326. PubMed ID: 35604839
[TBL] [Abstract][Full Text] [Related]
4. Evaluation of major historical ICR cell designs using electric field simulations.
Nikolaev E; Lioznov A
Mass Spectrom Rev; 2022 Mar; 41(2):262-283. PubMed ID: 33238049
[TBL] [Abstract][Full Text] [Related]
5. Fine Structure in Isotopic Peak Distributions Measured Using Fourier Transform Ion Cyclotron Resonance Mass Spectrometry: A Comparison between an Infinity ICR Cell and a Dynamically Harmonized ICR Cell.
Xu J; Li M; Marzullo B; Wootton CA; Barrow MP; O'Connor PB
J Am Soc Mass Spectrom; 2022 Aug; 33(8):1499-1509. PubMed ID: 35763614
[TBL] [Abstract][Full Text] [Related]
6. Potential of dynamically harmonized Fourier transform ion cyclotron resonance cell for high-throughput metabolomics fingerprinting: control of data quality.
Habchi B; Alves S; Jouan-Rimbaud Bouveresse D; Appenzeller B; Paris A; Rutledge DN; Rathahao-Paris E
Anal Bioanal Chem; 2018 Jan; 410(2):483-490. PubMed ID: 29167936
[TBL] [Abstract][Full Text] [Related]
7. Dynamically harmonized FT-ICR cell with specially shaped electrodes for compensation of inhomogeneity of the magnetic field. Computer simulations of the electric field and ion motion dynamics.
Kostyukevich YI; Vladimirov GN; Nikolaev EN
J Am Soc Mass Spectrom; 2012 Dec; 23(12):2198-207. PubMed ID: 22993044
[TBL] [Abstract][Full Text] [Related]
8. Absorption-mode spectra on the dynamically harmonized Fourier transform ion cyclotron resonance cell.
Qi Y; Witt M; Jertz R; Baykut G; Barrow MP; Nikolaev EN; O'Connor PB
Rapid Commun Mass Spectrom; 2012 Sep; 26(17):2021-6. PubMed ID: 22847701
[TBL] [Abstract][Full Text] [Related]
9. The coupling of direct analysis in real time ionization to Fourier transform ion cyclotron resonance mass spectrometry for ultrahigh-resolution mass analysis.
Rummel JL; McKenna AM; Marshall AG; Eyler JR; Powell DH
Rapid Commun Mass Spectrom; 2010 Mar; 24(6):784-90. PubMed ID: 20187081
[TBL] [Abstract][Full Text] [Related]
10. Fourier transform ion cyclotron resonance mass spectrometry at the true cyclotron frequency.
Nagornov KO; Tsybin OY; Nicol E; Kozhinov AN; Tsybin YO
Mass Spectrom Rev; 2022 Mar; 41(2):314-337. PubMed ID: 33462876
[TBL] [Abstract][Full Text] [Related]
11. Fourier transform ion cyclotron resonance mass spectrometry: a primer.
Marshall AG; Hendrickson CL; Jackson GS
Mass Spectrom Rev; 1998; 17(1):1-35. PubMed ID: 9768511
[TBL] [Abstract][Full Text] [Related]
12. A Top-Down Proteomics Platform Coupling Serial Size Exclusion Chromatography and Fourier Transform Ion Cyclotron Resonance Mass Spectrometry.
Tucholski T; Knott SJ; Chen B; Pistono P; Lin Z; Ge Y
Anal Chem; 2019 Mar; 91(6):3835-3844. PubMed ID: 30758949
[TBL] [Abstract][Full Text] [Related]
13. Fourier-transform ion cyclotron resonance mass spectrometry for characterizing proteoforms.
Tucholski T; Ge Y
Mass Spectrom Rev; 2022 Mar; 41(2):158-177. PubMed ID: 32894796
[TBL] [Abstract][Full Text] [Related]
14. High-resolution Fourier transform ion cyclotron resonance mass spectrometry with increased throughput for biomolecular analysis.
Nagornov KO; Gorshkov MV; Kozhinov AN; Tsybin YO
Anal Chem; 2014 Sep; 86(18):9020-8. PubMed ID: 25140615
[TBL] [Abstract][Full Text] [Related]
15. Assigning product ions from complex MS/MS spectra: the importance of mass uncertainty and resolving power.
Sleno L; Volmer DA; Marshall AG
J Am Soc Mass Spectrom; 2005 Feb; 16(2):183-98. PubMed ID: 15694769
[TBL] [Abstract][Full Text] [Related]
16. FT-ICR mass spectrometry: Superconducting magnet, external ion source, ion-molecule reactions, and ion-ion traps.
Wanczek KP; Kanawati B
Mass Spectrom Rev; 2022 Mar; 41(2):338-351. PubMed ID: 33521990
[TBL] [Abstract][Full Text] [Related]
17. Analytical Solution for the Electric Field Inside Dynamically Harmonized FT-ICR Cell.
Lioznov A; Baykut G; Nikolaev E
J Am Soc Mass Spectrom; 2019 May; 30(5):778-786. PubMed ID: 30825130
[TBL] [Abstract][Full Text] [Related]
18. Twelve million resolving power on 4.7 T Fourier transform ion cyclotron resonance instrument with dynamically harmonized cell--observation of fine structure in peptide mass spectra.
Popov IA; Nagornov K; Vladimirov GN; Kostyukevich YI; Nikolaev EN
J Am Soc Mass Spectrom; 2014 May; 25(5):790-9. PubMed ID: 24604470
[TBL] [Abstract][Full Text] [Related]
19. Uncoiling collagen: a multidimensional mass spectrometry study.
Simon HJ; van Agthoven MA; Lam PY; Floris F; Chiron L; Delsuc MA; Rolando C; Barrow MP; O'Connor PB
Analyst; 2016 Jan; 141(1):157-65. PubMed ID: 26568361
[TBL] [Abstract][Full Text] [Related]
20. Data processing in Fourier transform ion cyclotron resonance mass spectrometry.
Qi Y; O'Connor PB
Mass Spectrom Rev; 2014; 33(5):333-52. PubMed ID: 24403247
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]