These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
131 related articles for article (PubMed ID: 36253983)
61. A Novel Elastography Phantom Prototype for Assessment of Ultrasound Elastography Imaging Performance. Al-Mutairi FF; Chung EM; Moran CM; Ramnarine KV Ultrasound Med Biol; 2021 Sep; 47(9):2749-2758. PubMed ID: 34144833 [TBL] [Abstract][Full Text] [Related]
62. Which are the cut-off values of 2D-Shear Wave Elastography (2D-SWE) liver stiffness measurements predicting different stages of liver fibrosis, considering Transient Elastography (TE) as the reference method? Sporea I; Bota S; Gradinaru-Taşcău O; Sirli R; Popescu A; Jurchiş A Eur J Radiol; 2014 Mar; 83(3):e118-22. PubMed ID: 24380640 [TBL] [Abstract][Full Text] [Related]
63. Shear wave elastography for assessing the anterior scalene elasticity in patients with neck pain. Valera-Calero JA; Sánchez-Jiménez E; Plaza-Manzano G; Fernández-de-Las-Peñas C; Sánchez-Jorge S; José Navarro-Santana M Phys Med; 2024 May; 121():103356. PubMed ID: 38603998 [TBL] [Abstract][Full Text] [Related]
64. Motion effects on the measurement of stiffness on ultrasound shear wave elastography: a moving liver fibrosis phantom study. Shin HJ; Kim MJ; Yoon CS; Lee K; Lee KS; Park JC; Lee MJ; Yoon H Med Ultrason; 2018 Feb; 1(1):14-20. PubMed ID: 29400362 [TBL] [Abstract][Full Text] [Related]
65. Liver stiffness measurement reliability and main determinants of point shear-wave elastography in patients with chronic liver disease. Fraquelli M; Baccarin A; Casazza G; Conti CB; Giunta M; Massironi S; Invernizzi F; Donato MF; Maggioni M; Aghemo A; Conte D; Colombo M Aliment Pharmacol Ther; 2016 Aug; 44(4):356-65. PubMed ID: 27363587 [TBL] [Abstract][Full Text] [Related]
66. Normal Liver Stiffness Values in Children: A Comparison of Three Different Elastography Methods. Mjelle AB; Mulabecirovic A; Havre RF; Rosendahl K; Juliusson PB; Olafsdottir E; Gilja OH; Vesterhus M J Pediatr Gastroenterol Nutr; 2019 May; 68(5):706-712. PubMed ID: 30889132 [TBL] [Abstract][Full Text] [Related]
67. Measurement of shear wave speed dispersion in the placenta by transient elastography: A preliminary ex vivo study. Simon EG; Callé S; Perrotin F; Remenieras JP PLoS One; 2018; 13(4):e0194309. PubMed ID: 29621270 [TBL] [Abstract][Full Text] [Related]
68. Direct Comparison of US and MR Elastography for Staging Liver Fibrosis in Patients With Nonalcoholic Fatty Liver Disease. Imajo K; Honda Y; Kobayashi T; Nagai K; Ozaki A; Iwaki M; Kessoku T; Ogawa Y; Takahashi H; Saigusa Y; Yoneda M; Kirikoshi H; Utsunomiya D; Aishima S; Saito S; Nakajima A Clin Gastroenterol Hepatol; 2022 Apr; 20(4):908-917.e11. PubMed ID: 33340780 [TBL] [Abstract][Full Text] [Related]
69. Assessment of Liver and Spleen Stiffness in Patients With Myelofibrosis Using FibroScan and Shear Wave Elastography. Webb M; Shibolet O; Halpern Z; Nagar M; Amariglio N; Levit S; Steinberg DM; Santo E; Salomon O Ultrasound Q; 2015 Sep; 31(3):166-9. PubMed ID: 26366688 [TBL] [Abstract][Full Text] [Related]
70. Diagnostic Accuracy of Four Levels of Manual Compression Applied in Supersonic Shear Wave Elastography of the Breast. Chamming's F; Hangard C; Gennisson JL; Reinhold C; Fournier LS Acad Radiol; 2021 Apr; 28(4):481-486. PubMed ID: 32307273 [TBL] [Abstract][Full Text] [Related]
71. Liver and Spleen Stiffness Measurements by Point Shear Wave Elastography via Acoustic Radiation Force Impulse: Intraobserver and Interobserver Variability and Predictors of Variability in a US Population. Balakrishnan M; Souza F; Muñoz C; Augustin S; Loo N; Deng Y; Ciarleglio M; Garcia-Tsao G J Ultrasound Med; 2016 Nov; 35(11):2373-2380. PubMed ID: 27663656 [TBL] [Abstract][Full Text] [Related]
72. Value of Real-Time Shear Wave Elastography Versus Acoustic Radiation Force Impulse Imaging in the Diagnosis of Female Bladder Neck Obstruction. Qian M; Jiang D; Su C; Wang X; Zhao X; Yang S J Ultrasound Med; 2019 Sep; 38(9):2427-2435. PubMed ID: 30680774 [TBL] [Abstract][Full Text] [Related]
73. Diagnostic performance of quantitative shear wave elastography in the evaluation of solid breast masses: determination of the most discriminatory parameter. Au FW; Ghai S; Moshonov H; Kahn H; Brennan C; Dua H; Crystal P AJR Am J Roentgenol; 2014 Sep; 203(3):W328-36. PubMed ID: 25148191 [TBL] [Abstract][Full Text] [Related]
74. Diagnostic performances of shear wave elastography: which parameter to use in differential diagnosis of solid breast masses? Lee EJ; Jung HK; Ko KH; Lee JT; Yoon JH Eur Radiol; 2013 Jul; 23(7):1803-11. PubMed ID: 23423637 [TBL] [Abstract][Full Text] [Related]
75. Repeatability and Agreement of Shear Wave Speed Measurements in Phantoms and Human Livers Across 6 Ultrasound 2-Dimensional Shear Wave Elastography Systems. Gilligan LA; Trout AT; Bennett P; Dillman JR Invest Radiol; 2020 Apr; 55(4):191-199. PubMed ID: 31977604 [TBL] [Abstract][Full Text] [Related]
76. Can point shear wave elastography differentiate focal nodular hyperplasia from hepatocellular adenoma. Taimr P; Klompenhouwer AJ; Thomeer MGJ; Hansen BE; Ijzermans JNM; de Man RA; de Knegt RJ J Clin Ultrasound; 2018 Jul; 46(6):380-385. PubMed ID: 29740826 [TBL] [Abstract][Full Text] [Related]
77. Assessing Hepatic Fibrosis Using 2-D Shear Wave Elastography in Patients with Liver Tumors: A Prospective Single-Center Study. Huang Z; Zheng W; Zhang YJ; Xu L; Chen JB; Chen JC; Chen MS; Zhou Z Ultrasound Med Biol; 2017 Nov; 43(11):2522-2529. PubMed ID: 28807448 [TBL] [Abstract][Full Text] [Related]
78. Differential diagnosis of B-mode ultrasound Breast Imaging Reporting and Data System category 3-4a lesions in conjunction with shear-wave elastography using conservative and aggressive approaches. Zhi W; Miao A; You C; Zhou J; Zhang H; Zhu X; Wang Y; Chang C Quant Imaging Med Surg; 2022 Jul; 12(7):3833-3843. PubMed ID: 35782244 [TBL] [Abstract][Full Text] [Related]
79. Shear wave elastography using high-frequency linear probe for kidney transplant monitoring: A methodological study. Yang D; Zhuang B; Zheng Y; Xu M; Lin J; Zhang X; Wang C; Xie X; Huang G; Xie X; Wang Y Clin Hemorheol Microcirc; 2023; 84(2):165-176. PubMed ID: 37125543 [TBL] [Abstract][Full Text] [Related]
80. The usefulness of noninvasive liver stiffness assessment using shear-wave elastography for predicting liver fibrosis in children. Lee S; Choi YH; Cho YJ; Lee SB; Cheon JE; Kim WS; Ko JS; Koh J; Kang GH BMC Med Imaging; 2021 Apr; 21(1):68. PubMed ID: 33845776 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]