These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

85 related articles for article (PubMed ID: 36254755)

  • 1. Universal admission testing with a rapid molecular point-of-care test and real-time polymerase chain reaction (PCR) assay for the detection of severe acute respiratory coronavirus virus 2 (SARS-CoV-2): Comparative performance and infection prevention implications.
    Mena Lora AJ; Chaisson LH; Wenzler E; Borgetti S; Bleasdale SC
    Infect Control Hosp Epidemiol; 2023 Jan; 44(1):138-140. PubMed ID: 36254755
    [No Abstract]   [Full Text] [Related]  

  • 2. Nosocomial severe acute respiratory coronavirus virus 2 (SARS-CoV-2) transmission arising from a case of N-gene dropout on reverse-transcription polymerase chain reaction (RT-PCR) testing.
    Wee LEI; Ko KK; Conceicao EP; Aung MK; Aung MO; Yang Y; Arora S; Suphavilai C; Venkatachalam I
    Infect Control Hosp Epidemiol; 2023 Jan; 44(1):154-156. PubMed ID: 35775205
    [No Abstract]   [Full Text] [Related]  

  • 3. Miniaturized Real-Time PCR systems for SARS-CoV-2 detection at the Point-of-Care.
    Garzarelli V; Chiriacò MS; Cereda M; Autuori I; Ferrara F
    Clin Chim Acta; 2022 Nov; 536():104-111. PubMed ID: 36126763
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Rapid, Sensitive, and Specific Severe Acute Respiratory Syndrome Coronavirus 2 Detection: A Multicenter Comparison Between Standard Quantitative Reverse-Transcriptase Polymerase Chain Reaction and CRISPR-Based DETECTR.
    Brandsma E; Verhagen HJMP; van de Laar TJW; Claas ECJ; Cornelissen M; van den Akker E
    J Infect Dis; 2021 Feb; 223(2):206-213. PubMed ID: 33535237
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparative Performance of a New SARS-CoV-2 Rapid Detection System.
    Gori Savellini G; Anichini G; Terrosi C; Prathyumnan S; Gandolfo C; Marini S; Cusi MG
    Microbiol Spectr; 2021 Oct; 9(2):e0020521. PubMed ID: 34643409
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Novel dual multiplex real-time RT-PCR assays for the rapid detection of SARS-CoV-2, influenza A/B, and respiratory syncytial virus using the BD MAX open system.
    Chung HY; Jian MJ; Chang CK; Lin JC; Yeh KM; Chen CW; Chiu SK; Wang YH; Liao SJ; Li SY; Hsieh SS; Tsai SH; Perng CL; Yang JR; Liu MT; Chang FY; Shang HS
    Emerg Microbes Infect; 2021 Dec; 10(1):161-166. PubMed ID: 33410371
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reverse Transcription Recombinase-Aided Amplification Assay With Lateral Flow Dipstick Assay for Rapid Detection of 2019 Novel Coronavirus.
    Zheng YZ; Chen JT; Li J; Wu XJ; Wen JZ; Liu XZ; Lin LY; Liang XY; Huang HY; Zha GC; Yang PK; Li LJ; Zhong TY; Liu L; Cheng WJ; Song XN; Lin M
    Front Cell Infect Microbiol; 2021; 11():613304. PubMed ID: 33598439
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Extraction-Free Rapid Cycle Quantitative RT-PCR and Extreme RT-PCR for SARS-CoV-2 Virus Detection.
    Lownik JC; Way GW; Farrar JS; Martin RK
    J Mol Diagn; 2021 Dec; 23(12):1671-1679. PubMed ID: 34454108
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Performances of the VitaPCR™ SARS-CoV-2 Assay during the second wave of the COVID-19 epidemic in France.
    Fitoussi F; Dupont R; Tonen-Wolyec S; Bélec L
    J Med Virol; 2021 Jul; 93(7):4351-4357. PubMed ID: 33738829
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of mobile real-time polymerase chain reaction tests for the detection of severe acute respiratory syndrome coronavirus 2.
    Onyilagha C; Mistry H; Marszal P; Pinette M; Kobasa D; Tailor N; Berhane Y; Nfon C; Pickering B; Mubareka S; Bulir D; Chong S; Kozak R; Ambagala A
    Sci Rep; 2021 Apr; 11(1):9387. PubMed ID: 33931684
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An Ultra-Rapid Real-Time RT-PCR Method Using the PCR1100 to Detect Severe Acute Respiratory Syndrome Coronavirus-2.
    Shirato K; Nao N; Matsuyama S; Takeda M; Kageyama T
    Jpn J Infect Dis; 2021 Jan; 74(1):29-34. PubMed ID: 32611983
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Simultaneous detection of SARS-CoV-2 and identification of spike D614G mutation using point-of-care real-time polymerase chain reaction.
    Lee SY; Lee JS; Ahn JJ; Kim SJ; Sung H; Huh JW; Hwang SY
    J Virol Methods; 2022 Jun; 304():114513. PubMed ID: 35257681
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A comparative study on the efficiency of commercial reverse transcriptase-Polymerase chain reaction kits for the detection of severe acute respiratory syndrome coronavirus 2 infections.
    Ramalingam G; Dhanasezhian A; Murugesan A; Saminathan G; Sivathanu L
    Indian J Public Health; 2022; 66(3):276-281. PubMed ID: 36149104
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Diagnostic accuracy of the Cepheid Xpert Xpress and the Abbott ID NOW assay for rapid detection of SARS-CoV-2: A systematic review and meta-analysis.
    Lee J; Song JU
    J Med Virol; 2021 Jul; 93(7):4523-4531. PubMed ID: 33913533
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development, performance evaluation, and clinical application of a Rapid SARS-CoV-2 IgM and IgG Test Kit based on automated fluorescence immunoassay.
    Kang K; Huang L; Ouyang C; Du J; Yang B; Chi Y; He S; Ying L; Chen G; Wang J
    J Med Virol; 2021 May; 93(5):2838-2847. PubMed ID: 33231312
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Impact of coronavirus disease 2019 (COVID-19) pre-test probability on positive predictive value of high cycle threshold severe acute respiratory coronavirus virus 2 (SARS-CoV-2) real-time reverse transcription polymerase chain reaction (RT-PCR) test results.
    Gubbay JB; Rilkoff H; Kristjanson HL; Forbes JD; Murti M; Eshaghi A; Broukhanski G; Corbeil A; Fittipaldi N; Hopkins JP; Kristjanson E; Kus JV; Macdonald L; Majury A; Mallo GV; Mazzulli T; Melano RG; Olsha R; Perusini SJ; Tran V; Allen VG; Patel SN
    Infect Control Hosp Epidemiol; 2022 Sep; 43(9):1179-1183. PubMed ID: 34369325
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of a novel antigen detection test with reverse transcription polymerase chain reaction assay for laboratory diagnosis of SARS-CoV-2 infection.
    Cirit OS; Mutlu E; Sancak B; Kocagöz T; Can Ö; Çicek C; Arzu Sayiner A; Appak Ö; Uyar NY; Külah C; Çiçek AÇ; Özgümüs OB; Ay Altintop Y; Saatçi E; Karsligil T; Zer Y; Özen NS; Çekin Y; Karahan ZC; Evren E; Karakoç AE; Orhan SG; Mutlu D; Bozdemir T; Çayci YT; Çinar C; Tasbakan M; Mert M; Çinar E; Kutsoylu OÖE; Kocagöz S; Ertürk A; Çelik I; Mete AÖ; Günalp Eneyli M; Akdemir I; Karakök T; Inan D; Atilla A; Taflan ŞO; Yörük KE
    Infection; 2023 Feb; 51(1):91-96. PubMed ID: 35513690
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of extraction-based and elution-based polymerase chain reaction testing, and automated and rapid antigen testing for the diagnosis of severe acute respiratory syndrome coronavirus 2.
    Yoshioka N; Deguchi M; Hagiya H; Kagita M; Tsukamoto H; Takao M; Yoshida H; Hamaguchi S; Maeda I; Hidaka Y; Tomono K
    J Med Virol; 2022 Jul; 94(7):3155-3159. PubMed ID: 35274327
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Novel, Reverse Transcription, Droplet Digital PCR Assay for the Combined, Sensitive Detection of Severe Acute Respiratory Syndrome Coronavirus 2 with Swine Acute Diarrhea Syndrome Coronavirus.
    Zhang Z; Wang N; Liu X; Lv J; Jing H; Yuan X; Chen D; Lin X; Wu S
    J AOAC Int; 2022 Sep; 105(5):1437-1446. PubMed ID: 35377440
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Performance evaluation of Truenat™ Beta CoV & Truenat™ SARS-CoV-2 point-of-care assays for coronavirus disease 2019.
    Basawarajappa SG; Rangaiah A; Padukone S; Yadav PD; Gupta N; Shankar SM
    Indian J Med Res; 2021 Jan & Feb; 153(1 & 2):144-150. PubMed ID: 33818471
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.