These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 36256388)

  • 1. Influence of drift correction precision on super-resolution localization microscopy.
    Shang M; Huang ZL; Wang Y
    Appl Opt; 2022 May; 61(13):3516-3522. PubMed ID: 36256388
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Sub-nanometer drift correction for super-resolution imaging.
    Tang Y; Wang X; Zhang X; Li J; Dai L
    Opt Lett; 2014 Oct; 39(19):5685-8. PubMed ID: 25360959
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Real-time adaptive drift correction for super-resolution localization microscopy.
    Grover G; Mohrman W; Piestun R
    Opt Express; 2015 Sep; 23(18):23887-98. PubMed ID: 26368482
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High-precision 3D drift correction with differential phase contrast images.
    Shang M; Zhou Z; Kuang W; Wang Y; Xin B; Huang ZL
    Opt Express; 2021 Oct; 29(21):34641-34655. PubMed ID: 34809249
    [TBL] [Abstract][Full Text] [Related]  

  • 5. 3D drift correction for super-resolution imaging with a single laser light.
    Li Y; He Y; Fang K; Zhou L; Wang Z; Shi W; Li Y
    Opt Lett; 2024 May; 49(10):2785-2788. PubMed ID: 38748161
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Three dimensional drift control at nano-scale in single molecule localization microscopy.
    Fan X; Gensch T; Büldt G; Zhang Y; Musha Z; Zhang W; Roncarati R; Huang R
    Opt Express; 2020 Oct; 28(22):32750-32763. PubMed ID: 33114953
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Localization events-based sample drift correction for localization microscopy with redundant cross-correlation algorithm.
    Wang Y; Schnitzbauer J; Hu Z; Li X; Cheng Y; Huang ZL; Huang B
    Opt Express; 2014 Jun; 22(13):15982-91. PubMed ID: 24977854
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Two-color super-resolution localization microscopy via joint encoding of emitter location and color.
    Wang Y; Kuang W; Shang M; Huang ZL
    Opt Express; 2021 Oct; 29(21):34797-34809. PubMed ID: 34809261
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Sample drift correction in 3D fluorescence photoactivation localization microscopy.
    Mlodzianoski MJ; Schreiner JM; Callahan SP; Smolková K; Dlasková A; Santorová J; Ježek P; Bewersdorf J
    Opt Express; 2011 Aug; 19(16):15009-19. PubMed ID: 21934862
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Drift estimation for single marker switching based imaging schemes.
    Geisler C; Hotz T; Schönle A; Hell SW; Munk A; Egner A
    Opt Express; 2012 Mar; 20(7):7274-89. PubMed ID: 22453409
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Drift correction for single-molecule imaging by molecular constraint field, a distance minimum metric.
    Han R; Wang L; Xu F; Zhang Y; Zhang M; Liu Z; Ren F; Zhang F
    BMC Biophys; 2015; 8(1):1. PubMed ID: 25649266
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Motion screening of fiducial marker for improved localization precision and resolution in SMLM.
    Li K; Ni J; Tan X; Zhou Q; Chen D; Cao B; Lin J; Lin T; Zhao P; Yuan X; Ni Y
    Opt Express; 2023 Jul; 31(16):26764-26776. PubMed ID: 37710528
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Correction of image drift and distortion in a scanning electron microscopy.
    Jin P; Li X
    J Microsc; 2015 Dec; 260(3):268-80. PubMed ID: 26366744
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Sample drift estimation method based on speckle patterns formed by backscattered laser light.
    Chen SY; Heintzmann R; Cremer C
    Biomed Opt Express; 2019 Dec; 10(12):6462-6475. PubMed ID: 31853411
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Thermal nanoimprint lithography for drift correction in super-resolution fluorescence microscopy.
    Youn Y; Ishitsuka Y; Jin C; Selvin PR
    Opt Express; 2018 Jan; 26(2):1670-1680. PubMed ID: 29402038
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High-power homogeneous illumination for super-resolution localization microscopy with large field-of-view.
    Zhao Z; Xin B; Li L; Huang ZL
    Opt Express; 2017 Jun; 25(12):13382-13395. PubMed ID: 28788875
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Subwavelength motion-correction for ultrafast ultrasound localization microscopy.
    Hingot V; Errico C; Tanter M; Couture O
    Ultrasonics; 2017 May; 77():17-21. PubMed ID: 28167316
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Robust, fiducial-free drift correction for super-resolution imaging.
    Wester MJ; Schodt DJ; Mazloom-Farsibaf H; Fazel M; Pallikkuth S; Lidke KA
    Sci Rep; 2021 Dec; 11(1):23672. PubMed ID: 34880301
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measuring Image Resolution in Ultrasound Localization Microscopy.
    Hingot V; Chavignon A; Heiles B; Couture O
    IEEE Trans Med Imaging; 2021 Dec; 40(12):3812-3819. PubMed ID: 34280094
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Improved localization accuracy in stochastic super-resolution fluorescence microscopy by K-factor image deshadowing.
    Ilovitsh T; Meiri A; Ebeling CG; Menon R; Gerton JM; Jorgensen EM; Zalevsky Z
    Biomed Opt Express; 2013 Dec; 5(1):244-58. PubMed ID: 24466491
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.