These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
122 related articles for article (PubMed ID: 36265475)
1. Deep feature-domain matching for cardiac-related component separation from a chest electrical impedance tomography image series: proof-of-concept study. Zhang K; Li M; Liang H; Wang J; Yang F; Xu S; Abubakar A Physiol Meas; 2022 Dec; 43(12):. PubMed ID: 36265475 [No Abstract] [Full Text] [Related]
2. Separation of ventilation and perfusion of electrical impedance tomography image streams using multi-dimensional ensemble empirical mode decomposition. Hülkenberg AC; Ngo C; Lau R; Leonhardt S Physiol Meas; 2024 Jul; 45(7):. PubMed ID: 38925138 [No Abstract] [Full Text] [Related]
3. Dynamic separation of pulmonary and cardiac changes in electrical impedance tomography. Deibele JM; Luepschen H; Leonhardt S Physiol Meas; 2008 Jun; 29(6):S1-14. PubMed ID: 18544813 [TBL] [Abstract][Full Text] [Related]
4. Measurement of ventilation and cardiac related impedance changes with electrical impedance tomography. Grant CA; Pham T; Hough J; Riedel T; Stocker C; Schibler A Crit Care; 2011; 15(1):R37. PubMed ID: 21266025 [TBL] [Abstract][Full Text] [Related]
5. Separation of Heart and Lung-related Signals in Electrical Impedance Tomography Using Empirical Mode Decomposition. Cheng KS; Su PL; Ko YF Curr Med Imaging; 2022; 18(13):1396-1415. PubMed ID: 35570528 [TBL] [Abstract][Full Text] [Related]
6. A review on electrical impedance tomography for pulmonary perfusion imaging. Nguyen DT; Jin C; Thiagalingam A; McEwan AL Physiol Meas; 2012 May; 33(5):695-706. PubMed ID: 22532291 [TBL] [Abstract][Full Text] [Related]
7. Estimating regions of air trapping from electrical impedance tomography data. Mueller JL; Muller P; Mellenthin M; Murthy R; Capps M; Alsaker M; Deterding R; Sagel SD; DeBoer E Physiol Meas; 2018 May; 39(5):05NT01. PubMed ID: 29726838 [TBL] [Abstract][Full Text] [Related]
8. Deep learning based reconstruction enables high-resolution electrical impedance tomography for lung function assessment. Zeng S; Kwok WC; Cao P; Zouari F; Yun Lee PT; Chan RW; Touboul A Annu Int Conf IEEE Eng Med Biol Soc; 2023 Jul; 2023():1-4. PubMed ID: 38083133 [TBL] [Abstract][Full Text] [Related]
10. Event-triggered averaging of electrical impedance tomography (EIT) respiratory waveforms as compared to low-pass filtering for removal of cardiac related impedance changes. Coppadoro A; Eronia N; Foti G; Bellani G J Clin Monit Comput; 2020 Jun; 34(3):553-558. PubMed ID: 31278546 [TBL] [Abstract][Full Text] [Related]
11. Identification and analysis of stable breathing periods in electrical impedance tomography recordings. Haris K; Vogt B; Strodthoff C; Pessoa D; Cheimariotis GA; Rocha B; Petmezas G; Weiler N; Paiva RP; de Carvalho P; Maglaveras N; Frerichs I Physiol Meas; 2021 Jun; 42(6):. PubMed ID: 34098533 [No Abstract] [Full Text] [Related]
12. Wearable pulmonary monitoring system with integrated functional lung imaging and chest sound recording: a clinical investigation in healthy subjects. Frerichs I; Paradiso R; Kilintzis V; Rocha BM; Braun F; Rapin M; Caldani L; Beredimas N; Trechlis R; Suursalu S; Strodthoff C; Pessoa D; Chételat O; Paiva RP; de Carvalho P; Maglaveras N; Weiler N; Wacker J Physiol Meas; 2023 Apr; 44(4):. PubMed ID: 36975197 [No Abstract] [Full Text] [Related]
13. Electrical impedance tomography for assessing ventilation/perfusion mismatch for pulmonary embolism detection without interruptions in respiration. Nguyen DT; Thiagalingam A; Bhaskaran A; Barry MA; Pouliopoulos J; Jin C; McEwan AL Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():6068-71. PubMed ID: 25571381 [TBL] [Abstract][Full Text] [Related]
14. A randomised trial evaluating mask ventilation using electrical impedance tomography during anesthetic induction: one-handed technique versus two-handed technique. Gao L; Zhu Y; Pan C; Yin Y; Zhao Z; Yang L; Zhang J Physiol Meas; 2022 Jun; 43(6):. PubMed ID: 35580595 [No Abstract] [Full Text] [Related]
15. A model-based source separation algorithm for lung perfusion imaging using electrical impedance tomography. Hentze B; Muders T; Hoog Antink C; Putensen C; Larsson A; Hedenstierna G; Walter M; Leonhardt S Physiol Meas; 2021 Aug; 42(8):. PubMed ID: 34167091 [No Abstract] [Full Text] [Related]
16. Regional lung perfusion as determined by electrical impedance tomography in comparison with electron beam CT imaging. Frerichs I; Hinz J; Herrmann P; Weisser G; Hahn G; Quintel M; Hellige G IEEE Trans Med Imaging; 2002 Jun; 21(6):646-52. PubMed ID: 12166861 [TBL] [Abstract][Full Text] [Related]
17. What hinders pulmonary gas exchange and changes distribution of ventilation in immobilized white rhinoceroses ( Mosing M; Waldmann AD; Sacks M; Buss P; Boesch JM; Zeiler GE; Hosgood G; Gleed RD; Miller M; Meyer LCR; Böhm SH J Appl Physiol (1985); 2020 Nov; 129(5):1140-1149. PubMed ID: 33054661 [TBL] [Abstract][Full Text] [Related]
18. Monitoring of regional lung ventilation using electrical impedance tomography after cardiac surgery in infants and children. Krause U; Becker K; Hahn G; Dittmar J; Ruschewski W; Paul T Pediatr Cardiol; 2014 Aug; 35(6):990-7. PubMed ID: 24569885 [TBL] [Abstract][Full Text] [Related]
19. Optimized breath detection algorithm in electrical impedance tomography. Khodadad D; Nordebo S; Müller B; Waldmann A; Yerworth R; Becher T; Frerichs I; Sophocleous L; van Kaam A; Miedema M; Seifnaraghi N; Bayford R Physiol Meas; 2018 Sep; 39(9):094001. PubMed ID: 30074906 [TBL] [Abstract][Full Text] [Related]
20. Feature-space assessment of electrical impedance tomography coregistered with computed tomography in detecting multiple contrast targets. Krishnan K; Liu J; Kohli K Med Phys; 2014 Jun; 41(6):061903. PubMed ID: 24877814 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]