BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

221 related articles for article (PubMed ID: 36268707)

  • 1. First-in-Human Undermining Iatrogenic Coronary Obstruction With Radiofrequency Needle (UNICORN) Procedure During Valve-in-Valve Transcatheter Aortic Valve Replacement.
    Chan KE; Tai-Leung Chan D; Lam CS; Shu-Yue Sze M; Un KC; Tam CF; Lam YM; Wong CK
    Circ Cardiovasc Interv; 2022 Nov; 15(11):928-931. PubMed ID: 36268707
    [No Abstract]   [Full Text] [Related]  

  • 2. Novel valve-in-surgical bioprosthetic transcatheter aortic valve replacement: Undermining iatrogenic coronary obstruction with radiofrequency needle (UNICORN).
    Buchanan CE; Iskander M; Anwaruddin S; Mason PJ
    Catheter Cardiovasc Interv; 2024 May; 103(6):1069-1073. PubMed ID: 38584521
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Survivor of Acute and Delayed Coronary Obstruction After Valve-in-Valve Transcatheter Aortic Valve Replacement.
    Kanamori T; Fujino M; Takagi K; Asaumi Y; Fujita T; Noguchi T
    JACC Cardiovasc Interv; 2021 Oct; 14(19):2187-2188. PubMed ID: 34538603
    [No Abstract]   [Full Text] [Related]  

  • 4. Bail out lithotripsy to treat delayed valve-in-valve TAVR-related coronary obstruction.
    Bingen BO; Al Amri I; Montero-Cabezas JM; van der Kley F
    Catheter Cardiovasc Interv; 2023 Jan; 101(1):97-101. PubMed ID: 36385465
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Usefulness of intravascular ultrasound to assess coronary occlusion after transcatheter aortic valve replacement.
    Valvo R; Costa G; Tamburino C; Barbanti M
    Catheter Cardiovasc Interv; 2022 Apr; 99(5):1687-1690. PubMed ID: 35114070
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Rescue Management of a Coronary Artery Occlusion During a Transcatheter Aortic Valve Replacement.
    Yadlapalli D; Musuku SR; Pani S; Nappi AG
    J Cardiothorac Vasc Anesth; 2021 Apr; 35(4):1167-1171. PubMed ID: 32868153
    [No Abstract]   [Full Text] [Related]  

  • 7. A unique cause of coronary obstruction after transcatheter aortic valve replacement.
    Chang CW; Wadia SK; Rastogi A; Stinis CT
    Catheter Cardiovasc Interv; 2021 Nov; 98(6):E823-E827. PubMed ID: 34415672
    [TBL] [Abstract][Full Text] [Related]  

  • 8. White Line Sign of Impending Coronary Occlusion in Transcatheter Aortic Valve Replacement.
    Rambod M; Terrien EF; Dauerman HL
    Circ Cardiovasc Interv; 2017 Mar; 10(3):. PubMed ID: 28280236
    [No Abstract]   [Full Text] [Related]  

  • 9. Rescue of Threatened Coronary Obstruction Due to Sinus Sequestration: Valve-in-Valve Transcatheter Aortic Valve Replacement.
    Kadavath SM; Terrien EF; Ittleman FP; Lahoud R; Phuong NP; Dauerman HL
    JACC Cardiovasc Interv; 2021 May; 14(9):1033-1035. PubMed ID: 33865739
    [No Abstract]   [Full Text] [Related]  

  • 10. Zero-Contrast Transcatheter Aortic Valve-in-Valve Implantation Using Intravascular Ultrasound to Evaluate Coronary Obstruction Risk.
    Takahashi T; Kobayashi Y; Chau ML; Latib A
    Circ J; 2021 Dec; 86(1):168. PubMed ID: 34373433
    [No Abstract]   [Full Text] [Related]  

  • 11. Coronary obstruction after transcatheter aortic valve replacement combined with basilica procedure.
    Tafciu E; Rossi A; Pighi M; Pesarini G; Ribichini FL
    Eur Heart J Cardiovasc Imaging; 2021 May; 22(6):e81. PubMed ID: 33230548
    [No Abstract]   [Full Text] [Related]  

  • 12. Delayed coronary obstruction after lotus transcatheter aortic valve replacement treated with left main stent in stent implantation.
    Krisper M; Toselli M; Trippel TD; Pieske BM; Krackhardt F
    Cardiol J; 2019; 26(4):422-423. PubMed ID: 31452189
    [No Abstract]   [Full Text] [Related]  

  • 13. Late-Phase Delayed Coronary Obstruction Caused by Protruding Calcified Aortic Valve Leaflet After Balloon-Expandable Transcatheter Aortic Valve Replacement.
    Yasumura K; Goel S; Krishnamoorthy P; Lee SM; Sharma SK; Tang GHL; Kini AS
    Circ Cardiovasc Imaging; 2021 Sep; 14(9):e012854. PubMed ID: 34445882
    [No Abstract]   [Full Text] [Related]  

  • 14. IVUS Imaging of Endothelialization of an Implanted Transcatheter Aortic Valve Causing Delayed Coronary Obstruction.
    Mukaida T; Honda S; Yoneda S; Takagi K; Kataoka Y; Noguchi T
    JACC Cardiovasc Interv; 2023 Aug; 16(16):2040-2042. PubMed ID: 37294225
    [No Abstract]   [Full Text] [Related]  

  • 15. Leaflet modification or chimney stenting in patients at risk for coronary artery obstruction in valve-in-valve procedure for a failed surgical bioprosthetic aortic valve.
    Montarello NJ; Quagliana A; Søndergaard L; De Backer O
    Catheter Cardiovasc Interv; 2023 Feb; 101(3):655-659. PubMed ID: 36651342
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Coronary obstruction occurring 72h after transcatheter aortic valve replacement with a self-expandable valve.
    Miyazaki Y; Okamura T; Fujita A; Mikamo A; Oda T; Wada Y; Yamashita A; Suzuki R; Takahashi M; Hamano K; Yano M
    Int J Cardiol; 2016 Nov; 223():1-3. PubMed ID: 27522267
    [No Abstract]   [Full Text] [Related]  

  • 17. Transcatheter Laceration of Aortic Leaflets to Prevent Coronary Obstruction During Transcatheter Aortic Valve Replacement: Concept to First-in-Human.
    Khan JM; Dvir D; Greenbaum AB; Babaliaros VC; Rogers T; Aldea G; Reisman M; Mackensen GB; Eng MHK; Paone G; Wang DD; Guyton RA; Devireddy CM; Schenke WH; Lederman RJ
    JACC Cardiovasc Interv; 2018 Apr; 11(7):677-689. PubMed ID: 29622147
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Bioprosthetic Aortic Scallop Intentional Laceration to prevent Iatrogenic Coronary Artery obstruction (BASILICA) in valve-in-valve Transcatheter Aortic Valve Implantation (ViV-TAVI): First experience in Poland.
    Jędrzejczyk S; Rymuza B; Ścisło P; Grodecki K; Pędzich-Placha E; Grabowski M; Kochman J; Huczek Z
    Kardiol Pol; 2022; 80(12):1266-1267. PubMed ID: 36161589
    [No Abstract]   [Full Text] [Related]  

  • 19. Coronary Occlusion During Transcatheter Aortic Valve Replacement With an Anomalous Origin of Left Coronary Artery.
    Yashima F; Inohara T; Hashizume K; Ueno K; Fukuda K
    JACC Cardiovasc Interv; 2021 Aug; 14(16):e217-e218. PubMed ID: 34332947
    [No Abstract]   [Full Text] [Related]  

  • 20. Coronary Artery Obstruction After Transcatheter Aortic Valve Implantation: Past, Present, and Future.
    Ibrahim H; Chaus A; Alkhalil A; Prescher L; Kleiman N
    Circ Cardiovasc Interv; 2024 Jun; 17(6):e012827. PubMed ID: 38818724
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.