These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

269 related articles for article (PubMed ID: 36269371)

  • 1. Evaluating prostate cancer bone metastasis using accelerated whole-body isotropic 3D T1-weighted Dixon MRI with compressed SENSE: a feasibility study.
    Liao Z; Liu G; Ming B; Ma C; Fan X; Zhang X; Peng W; Liu C
    Eur Radiol; 2023 Mar; 33(3):1719-1728. PubMed ID: 36269371
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Generating synthetic high-resolution spinal STIR and T1w images from T2w FSE and low-resolution axial Dixon.
    Graf R; Platzek PS; Riedel EO; Kim SH; Lenhart N; Ramschütz C; Paprottka KJ; Kertels OR; Möller HK; Atad M; Bülow R; Werner N; Völzke H; Schmidt CO; Wiestler B; Paetzold JC; Rueckert D; Kirschke JS
    Eur Radiol; 2024 Sep; ():. PubMed ID: 39231829
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Whole-body 3D T1-weighted MR imaging in patients with prostate cancer: feasibility and evaluation in screening for metastatic disease.
    Pasoglou V; Michoux N; Peeters F; Larbi A; Tombal B; Selleslagh T; Omoumi P; Vande Berg BC; Lecouvet FE
    Radiology; 2015 Apr; 275(1):155-66. PubMed ID: 25513855
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Feasibility of Artificial Intelligence Constrained Compressed SENSE Accelerated 3D Isotropic T1 VISTA Sequence For Vessel Wall MR Imaging: Exploring the Potential of Higher Acceleration Factors Compared to Traditional Compressed SENSE.
    Ma Y; Wang M; Qiao Y; Wen Y; Zhu Y; Jiang K; Lian J; Tong D
    Acad Radiol; 2024 Oct; 31(10):3971-3981. PubMed ID: 38664146
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Whole-body MRI in oncology: can a single anatomic T2 Dixon sequence replace the combination of T1 and STIR sequences to detect skeletal metastasis and myeloma?
    Chiabai O; Van Nieuwenhove S; Vekemans MC; Tombal B; Peeters F; Wuts J; Triqueneaux P; Omoumi P; Kirchgesner T; Michoux N; Lecouvet FE
    Eur Radiol; 2023 Jan; 33(1):244-257. PubMed ID: 35925384
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparing T1-weighted and T2-weighted three-point Dixon technique with conventional T1-weighted fat-saturation and short-tau inversion recovery (STIR) techniques for the study of the lumbar spine in a short-bore MRI machine.
    Brandão S; Seixas D; Ayres-Basto M; Castro S; Neto J; Martins C; Ferreira JC; Parada F
    Clin Radiol; 2013 Nov; 68(11):e617-23. PubMed ID: 23932678
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Whole-body MRI including diffusion-weighted imaging (DWI) for patients with recurring prostate cancer: technical feasibility and assessment of lesion conspicuity in DWI.
    Eiber M; Holzapfel K; Ganter C; Epple K; Metz S; Geinitz H; Kübler H; Gaa J; Rummeny EJ; Beer AJ
    J Magn Reson Imaging; 2011 May; 33(5):1160-70. PubMed ID: 21509875
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fast 3D Isotropic Proton Density-Weighted Fat-Saturated MRI of the Knee at 1.5 T with Compressed Sensing: Comparison with Conventional Multiplanar 2D Sequences.
    Endler CH; Faron A; Isaak A; Katemann C; Mesropyan N; Kupczyk PA; Pieper CC; Kuetting D; Hadizadeh DR; Attenberger UI; Luetkens JA
    Rofo; 2021 Jul; 193(7):813-821. PubMed ID: 33535259
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical Feasibility of Gadoxetic Acid-Enhanced Isotropic High-Resolution 3-Dimensional Magnetic Resonance Cholangiography Using an Iterative Denoising Algorithm for Evaluation of the Biliary Anatomy of Living Liver Donors.
    Kang HJ; Lee JM; Ahn SJ; Bae JS; Kannengiesser S; Kiefer B; Suh KS
    Invest Radiol; 2019 Feb; 54(2):103-109. PubMed ID: 30281556
    [TBL] [Abstract][Full Text] [Related]  

  • 10. T2 Turbo Spin Echo With Compressed Sensing and Propeller Acquisition (Sampling k-Space by Utilizing Rotating Blades) for Fast and Motion Robust Prostate MRI: Comparison With Conventional Acquisition.
    Bischoff LM; Katemann C; Isaak A; Mesropyan N; Wichtmann B; Kravchenko D; Endler C; Kuetting D; Pieper CC; Ellinger J; Weber O; Attenberger U; Luetkens JA
    Invest Radiol; 2023 Mar; 58(3):209-215. PubMed ID: 36070533
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of high-resolution T1W 3D GRE (LAVA) with 2-point Dixon fat/water separation (FLEX) to T1W fast spin echo (FSE) in prostate cancer (PCa).
    Samji K; Alrashed A; Shabana WM; McInnes MD; Bayram E; Schieda N
    Clin Imaging; 2016; 40(3):407-13. PubMed ID: 27133677
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Whole-body MRI to assess bone involvement in prostate cancer and multiple myeloma: comparison of the diagnostic accuracies of the T1, short tau inversion recovery (STIR), and high b-values diffusion-weighted imaging (DWI) sequences.
    Larbi A; Omoumi P; Pasoglou V; Michoux N; Triqueneaux P; Tombal B; Cyteval C; Lecouvet FE
    Eur Radiol; 2019 Aug; 29(8):4503-4513. PubMed ID: 30413957
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comprehensive Dynamic Contrast-Enhanced 3D Magnetic Resonance Imaging of the Breast With Fat/Water Separation and High Spatiotemporal Resolution Using Radial Sampling, Compressed Sensing, and Parallel Imaging.
    Benkert T; Block KT; Heller S; Moccaldi M; Sodickson DK; Kim SG; Moy L
    Invest Radiol; 2017 Oct; 52(10):583-589. PubMed ID: 28398929
    [TBL] [Abstract][Full Text] [Related]  

  • 14. 3.0 T unenhanced Dixon water-fat separation whole-heart coronary magnetic resonance angiography: compressed-sensing sensitivity encoding imaging versus conventional 2D sensitivity encoding imaging.
    Tian D; Sun Y; Guo JJ; Zhao SH; Lu HF; Chen YY; Ge MY; Zeng MS; Jin H
    Int J Cardiovasc Imaging; 2023 Sep; 39(9):1775-1784. PubMed ID: 37428247
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Conspicuity of bone metastases on fast Dixon-based multisequence whole-body MRI: clinical utility per sequence.
    Costelloe CM; Madewell JE; Kundra V; Harrell RK; Bassett RL; Ma J
    Magn Reson Imaging; 2013 Jun; 31(5):669-75. PubMed ID: 23290478
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Compressed Sensing SEMAC: 8-fold Accelerated High Resolution Metal Artifact Reduction MRI of Cobalt-Chromium Knee Arthroplasty Implants.
    Fritz J; Ahlawat S; Demehri S; Thawait GK; Raithel E; Gilson WD; Nittka M
    Invest Radiol; 2016 Oct; 51(10):666-76. PubMed ID: 27518214
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Shortening the acquisition time of whole-body MRI: 3D T1 gradient echo Dixon vs fast spin echo for metastatic screening in prostate cancer.
    Lecouvet FE; Pasoglou V; Van Nieuwenhove S; Van Haver T; de Broqueville Q; Denolin V; Triqueneaux P; Tombal B; Michoux N
    Eur Radiol; 2020 Jun; 30(6):3083-3093. PubMed ID: 32065282
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Deep Learning Reconstruction of Prospectively Accelerated MRI of the Pancreas: Clinical Evaluation of Shortened Breath-Hold Examinations With Dixon Fat Suppression.
    Chaika M; Brendel JM; Ursprung S; Herrmann J; Gassenmaier S; Brendlin A; Werner S; Nickel MD; Nikolaou K; Afat S; Almansour H
    Invest Radiol; 2024 Jul; ():. PubMed ID: 39043213
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Compressed Sensing-Sensitivity Encoding (CS-SENSE) Accelerated Brain Imaging: Reduced Scan Time without Reduced Image Quality.
    Vranic JE; Cross NM; Wang Y; Hippe DS; de Weerdt E; Mossa-Basha M
    AJNR Am J Neuroradiol; 2019 Jan; 40(1):92-98. PubMed ID: 30523142
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of MRI Sequences in Whole-Body PET/MRI for Staging of Patients With High-Risk Prostate Cancer.
    Metser U; Chan R; Veit-Haibach P; Ghai S; Tau N
    AJR Am J Roentgenol; 2019 Feb; 212(2):377-381. PubMed ID: 30332285
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.