These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 36278402)

  • 1. Improving the Bias of Comparator Methods in Analytical Performance Assessments Through Recalibration.
    Pleus S; Eichenlaub M; Gerber T; Eriksson Boija E; Makris K; Haug C; Freckmann G
    J Diabetes Sci Technol; 2024 May; 18(3):686-694. PubMed ID: 36278402
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Application of the reference method isotope dilution gas chromatography mass spectrometry (ID/GC/MS) to establish metrological traceability for calibration and control of blood glucose test systems.
    Andreis E; Küllmer K; Appel M
    J Diabetes Sci Technol; 2014 May; 8(3):508-15. PubMed ID: 24876614
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Modeling the error of continuous glucose monitoring sensor data: critical aspects discussed through simulation studies.
    Facchinetti A; Sparacino G; Cobelli C
    J Diabetes Sci Technol; 2010 Jan; 4(1):4-14. PubMed ID: 20167162
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Folic acid supplementation and malaria susceptibility and severity among people taking antifolate antimalarial drugs in endemic areas.
    Crider K; Williams J; Qi YP; Gutman J; Yeung L; Mai C; Finkelstain J; Mehta S; Pons-Duran C; Menéndez C; Moraleda C; Rogers L; Daniels K; Green P
    Cochrane Database Syst Rev; 2022 Feb; 2(2022):. PubMed ID: 36321557
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessing the analytical performance of systems for self-monitoring of blood glucose: concepts of performance evaluation and definition of metrological key terms.
    Schnell O; Hinzmann R; Kulzer B; Freckmann G; Erbach M; Lodwig V; Heinemann L
    J Diabetes Sci Technol; 2013 Nov; 7(6):1585-94. PubMed ID: 24351185
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Impact of Two Different Reference Measurement Procedures on Apparent System Accuracy of 18 CE-Marked Current-Generation Blood Glucose Monitoring Systems.
    Freckmann G; Baumstark A; Jendrike N; Mende J; Schauer S; Link M; Pleus S; Haug C
    J Diabetes Sci Technol; 2022 Sep; 16(5):1076-1088. PubMed ID: 32814455
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Standard technical specifications for methacholine chloride (Methacholine) bronchial challenge test (2023)].
    ; ;
    Zhonghua Jie He He Hu Xi Za Zhi; 2024 Feb; 47(2):101-119. PubMed ID: 38309959
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Reducing analytical variation between point-of-care and laboratory HbA1c testing.
    Malkani S; Korpi-Steiner N; Rao LV
    J Diabetes; 2013 Jun; 5(2):192-6. PubMed ID: 23035661
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Results of the recalibration of creatinine measurement with the modular Beckman Coulter Jaffe creatinine method.
    Fillée C; Vranken G; Othmane M; Philippe M; Allaeys JM; Courbe A; Ruelle JL; Peeters R
    Clin Chem Lab Med; 2011 Dec; 49(12):1987-99. PubMed ID: 21801031
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Traceability to a primary reference measurement procedure (ID-LCMS); A key step in validating the clinical accuracy and safety of hospital blood glucose monitoring systems.
    Wang Y; Hu X; Tang J; Wang W; Dong L; Gu C; Zhou J; Jia W
    Clin Chim Acta; 2018 Nov; 486():275-281. PubMed ID: 30125535
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Estimates of total analytical error in consumer and hospital glucose meters contributed by hematocrit, maltose, and ascorbate.
    Lyon ME; DuBois JA; Fick GH; Lyon AW
    J Diabetes Sci Technol; 2010 Nov; 4(6):1479-94. PubMed ID: 21129345
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Assessment of System Accuracy, Intermediate Measurement Precision, and Measurement Repeatability of a Blood Glucose Monitoring System Based on ISO 15197.
    Jendrike N; Baumstark A; Pleus S; Mende J; Haug C; Freckmann G
    J Diabetes Sci Technol; 2019 Mar; 13(2):235-241. PubMed ID: 30547683
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Performance evaluations of continuous glucose monitoring systems: precision absolute relative deviation is part of the assessment.
    Obermaier K; Schmelzeisen-Redeker G; Schoemaker M; Klötzer HM; Kirchsteiger H; Eikmeier H; del Re L
    J Diabetes Sci Technol; 2013 Jul; 7(4):824-32. PubMed ID: 23911163
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Recalibration of blood analytes over 25 years in the atherosclerosis risk in communities study: impact of recalibration on chronic kidney disease prevalence and incidence.
    Parrinello CM; Grams ME; Couper D; Ballantyne CM; Hoogeveen RC; Eckfeldt JH; Selvin E; Coresh J
    Clin Chem; 2015 Jul; 61(7):938-47. PubMed ID: 25952043
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of hematocrit bias on blood glucose measurement with six different portable glucose meters.
    Daves M; Cemin R; Fattor B; Cosio G; Salvagno GL; Rizza F; Lippi G
    Biochem Med (Zagreb); 2011; 21(3):306-11. PubMed ID: 22420245
    [TBL] [Abstract][Full Text] [Related]  

  • 16. System accuracy evaluation of 43 blood glucose monitoring systems for self-monitoring of blood glucose according to DIN EN ISO 15197.
    Freckmann G; Schmid C; Baumstark A; Pleus S; Link M; Haug C
    J Diabetes Sci Technol; 2012 Sep; 6(5):1060-75. PubMed ID: 23063032
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Analytical Performance Requirements for Systems for Self-Monitoring of Blood Glucose With Focus on System Accuracy: Relevant Differences Among ISO 15197:2003, ISO 15197:2013, and Current FDA Recommendations.
    Freckmann G; Schmid C; Baumstark A; Rutschmann M; Haug C; Heinemann L
    J Diabetes Sci Technol; 2015 Jul; 9(4):885-94. PubMed ID: 25872965
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A human pilot study of the fluorescence affinity sensor for continuous glucose monitoring in diabetes.
    Dutt-Ballerstadt R; Evans C; Pillai AP; Orzeck E; Drabek R; Gowda A; McNichols R
    J Diabetes Sci Technol; 2012 Mar; 6(2):362-70. PubMed ID: 22538148
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Personalized Week-to-Week Updating Algorithm to Improve Continuous Glucose Monitoring Performance.
    Zavitsanou S; Lee JB; Pinsker JE; Church MM; Doyle FJ; Dassau E
    J Diabetes Sci Technol; 2017 Nov; 11(6):1070-1079. PubMed ID: 29032732
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of a novel continuous glucose measurement device in patients with diabetes mellitus across the glycemic range.
    Morrow L; Hompesch M; Tideman AM; Matson J; Dunne N; Pardo S; Parkes JL; Schachner HC; Simmons DA
    J Diabetes Sci Technol; 2011 Jul; 5(4):853-9. PubMed ID: 21880226
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.