These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 36279962)

  • 1. Comparative flow cytometry-based immunophenotyping analysis of peripheral blood leukocytes before and after fixation with paraformaldehyde.
    Vistica Sampino E; Morgan J; Chorzalska A; Nguyen L; Yu C; Rodriguez A; Pardo M; Bonal D; Liang O; Kim M; De Vito R; Lulla RR; Dubielecka PM
    J Immunol Methods; 2022 Dec; 511():113379. PubMed ID: 36279962
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Rapid single-step method for flow cytometric detection of surface and intracellular antigens using whole blood.
    Francis C; Connelly MC
    Cytometry; 1996 Sep; 25(1):58-70. PubMed ID: 8875055
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Changes in fluorescence intensity of selected leukocyte surface markers following fixation.
    Stewart JC; Villasmil ML; Frampton MW
    Cytometry A; 2007 Jun; 71(6):379-85. PubMed ID: 17326232
    [TBL] [Abstract][Full Text] [Related]  

  • 4. OMIP-069: Forty-Color Full Spectrum Flow Cytometry Panel for Deep Immunophenotyping of Major Cell Subsets in Human Peripheral Blood.
    Park LM; Lannigan J; Jaimes MC
    Cytometry A; 2020 Oct; 97(10):1044-1051. PubMed ID: 32830910
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Design of a multi-center immunophenotyping analysis of peripheral blood, sputum and bronchoalveolar lavage fluid in the Subpopulations and Intermediate Outcome Measures in COPD Study (SPIROMICS).
    Freeman CM; Crudgington S; Stolberg VR; Brown JP; Sonstein J; Alexis NE; Doerschuk CM; Basta PV; Carretta EE; Couper DJ; Hastie AT; Kaner RJ; O'Neal WK; Paine R; Rennard SI; Shimbo D; Woodruff PG; Zeidler M; Curtis JL
    J Transl Med; 2015 Jan; 13():19. PubMed ID: 25622723
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Standardisation of flow cytometry for whole blood immunophenotyping of islet transplant and transplant clinical trial recipients.
    Jimenez Vera E; Chew YV; Nicholson L; Burns H; Anderson P; Chen HT; Williams L; Keung K; Zanjani NT; Dervish S; Patrick E; Wang XM; Yi S; Hawthorne W; Alexander S; O'Connell PJ; Hu M
    PLoS One; 2019; 14(5):e0217163. PubMed ID: 31116766
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Eight-color panel for immune phenotype monitoring by flow cytometry.
    Cardoso CC; Santos-Silva MC
    J Immunol Methods; 2019 May; 468():40-48. PubMed ID: 30914269
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development of a Modular Assay for Detailed Immunophenotyping of Peripheral Human Whole Blood Samples by Multicolor Flow Cytometry.
    Rühle PF; Fietkau R; Gaipl US; Frey B
    Int J Mol Sci; 2016 Aug; 17(8):. PubMed ID: 27529227
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Stabilization of leukocytes from cerebrospinal fluid for central immunophenotypic evaluation in multicenter clinical trials.
    Mexhitaj I; Lim N; Fernandez-Velasco JI; Zrzavy T; Harris KM; Muraro PA; Villar LM; Bar-Or A; Cooney LA
    J Immunol Methods; 2022 Nov; 510():113344. PubMed ID: 36041516
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A comprehensive multiparameter flow cytometry panel for immune profiling and functional studies of frozen tissue, bone marrow, and spleen.
    Wu YC; Kissner M; Momen-Heravi F
    J Immunol Methods; 2023 Apr; 515():113444. PubMed ID: 36868498
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Eight-color immunophenotyping of T-, B-, and NK-cell subpopulations for characterization of chronic immunodeficiencies.
    Boldt A; Borte S; Fricke S; Kentouche K; Emmrich F; Borte M; Kahlenberg F; Sack U
    Cytometry B Clin Cytom; 2014 May; 86(3):191-206. PubMed ID: 24488780
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comprehensive assessment of immunophenotyping performed in cryopreserved peripheral whole blood.
    Verschoor CP; Kohli V; Balion C
    Cytometry B Clin Cytom; 2018 Sep; 94(5):662-670. PubMed ID: 28378896
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An easy and reliable whole blood freezing method for flow cytometry immuno-phenotyping and functional analyses.
    Braudeau C; Salabert-Le Guen N; Chevreuil J; Rimbert M; Martin JC; Josien R
    Cytometry B Clin Cytom; 2021 Nov; 100(6):652-665. PubMed ID: 33544978
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of immunophenotyping by slide-based cytometry and by flow cytometry.
    Gerstner AO; Mittag A; Laffers W; Dähnert I; Lenz D; Bootz F; Bocsi J; Tárnok A
    J Immunol Methods; 2006 Apr; 311(1-2):130-8. PubMed ID: 16527301
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Extended immunophenotyping reference values in a healthy pediatric population.
    Garcia-Prat M; Álvarez-Sierra D; Aguiló-Cucurull A; Salgado-Perandrés S; Briongos-Sebastian S; Franco-Jarava C; Martin-Nalda A; Colobran R; Montserrat I; Hernández-González M; Pujol-Borrell R; Soler-Palacin P; Martínez-Gallo M
    Cytometry B Clin Cytom; 2019 May; 96(3):223-233. PubMed ID: 30334372
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of a 10color protocol as part of a 2tube screening panel for flow cytometric assessment of peripheral blood leukocytic subsets.
    Gounari E; Tsavdaridou V; Ioakeimidou A; Haidich AB; Skoura L
    Scand J Clin Lab Invest; 2019 Nov; 79(7):475-483. PubMed ID: 31497995
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Panel Optimization for High-Dimensional Immunophenotyping Assays Using Full-Spectrum Flow Cytometry.
    Ferrer-Font L; Small SJ; Lewer B; Pilkington KR; Johnston LK; Park LM; Lannigan J; Jaimes MC; Price KM
    Curr Protoc; 2021 Sep; 1(9):e222. PubMed ID: 34492732
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Optimizing Flow Cytometric Analysis of Immune Cells in Samples Requiring Cryopreservation from Tumor-Bearing Mice.
    Carlson PM; Mohan M; Patel RB; Birstler J; Nettenstrom L; Sheerar D; Fox K; Rodriguez M; Hoefges A; Hernandez R; Zahm C; Kim K; McNeel DG; Weichert J; Morris ZS; Sondel PM
    J Immunol; 2021 Jul; 207(2):720-734. PubMed ID: 34261667
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Detection of Basophils and Other Granulocytes in Induced Sputum by Flow Cytometry.
    Rohner L; Fux M
    Methods Mol Biol; 2020; 2163():281-291. PubMed ID: 32766984
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Sequential paraformaldehyde and methanol fixation for simultaneous flow cytometric analysis of DNA, cell surface proteins, and intracellular proteins.
    Pollice AA; McCoy JP; Shackney SE; Smith CA; Agarwal J; Burholt DR; Janocko LE; Hornicek FJ; Singh SG; Hartsock RJ
    Cytometry; 1992; 13(4):432-44. PubMed ID: 1382010
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.