130 related articles for article (PubMed ID: 36280573)
1. The influence of patient positioning on radiation dose in CT imaging: A narrative review.
Al-Hayek Y; Zheng X; Hayre C; Spuur K
J Med Imaging Radiat Sci; 2022 Dec; 53(4):737-747. PubMed ID: 36280573
[TBL] [Abstract][Full Text] [Related]
2. 0° vs. 180° CT localiser: The effect of vertical off-centring, phantom positioning and tube voltage on dose optimisation in multidetector computed tomography.
Al-Hayek Y; Zheng X; Davidson R; Hayre C; Al-Mousa D; Finlay C; Spuur K
J Med Radiat Sci; 2022 Mar; 69(1):5-12. PubMed ID: 34402591
[TBL] [Abstract][Full Text] [Related]
3. Precise and Automatic Patient Positioning in Computed Tomography: Avatar Modeling of the Patient Surface Using a 3-Dimensional Camera.
Saltybaeva N; Schmidt B; Wimmer A; Flohr T; Alkadhi H
Invest Radiol; 2018 Nov; 53(11):641-646. PubMed ID: 29762259
[TBL] [Abstract][Full Text] [Related]
4. The Impacts of Vertical Off-Centring, Localiser Direction, Phantom Positioning and Tube Voltage on CT Number Accuracy: An Experimental Study.
Al-Hayek Y; Spuur K; Davidson R; Hayre C; Zheng X
J Imaging; 2022 Jun; 8(7):. PubMed ID: 35877619
[TBL] [Abstract][Full Text] [Related]
5. How patient off-centering impacts organ dose and image noise in pediatric head and thoracoabdominal CT.
Euler A; Saltybaeva N; Alkadhi H
Eur Radiol; 2019 Dec; 29(12):6790-6793. PubMed ID: 31278575
[TBL] [Abstract][Full Text] [Related]
6. The reliability of CT numbers as absolute values for diagnostic scanning, dental imaging, and radiation therapy simulation: A narrative review.
Al-Hayek Y; Spuur K; Zheng X; Hayre C; Davidson R
J Med Imaging Radiat Sci; 2022 Mar; 53(1):138-146. PubMed ID: 34911666
[TBL] [Abstract][Full Text] [Related]
7. Accuracy of automated patient positioning in CT using a 3D camera for body contour detection.
Booij R; Budde RPJ; Dijkshoorn ML; van Straten M
Eur Radiol; 2019 Apr; 29(4):2079-2088. PubMed ID: 30306328
[TBL] [Abstract][Full Text] [Related]
8. IMPLICATIONS OF PATIENT CENTRING ON ORGAN DOSE IN COMPUTED TOMOGRAPHY.
Kataria B; Sandborg M; Althén JN
Radiat Prot Dosimetry; 2016 Jun; 169(1-4):130-5. PubMed ID: 26743256
[TBL] [Abstract][Full Text] [Related]
9. Influence of tube and patient positioning in thoracoabdominal CT examinations on radiation exposure-towards a better patient positioning.
Valentin B; Kamp B; Henke J; Ljimani A; Appel E; Antoch G; Steuwe A
J Radiol Prot; 2023 Sep; 43(3):. PubMed ID: 37619552
[TBL] [Abstract][Full Text] [Related]
10. Vertical Off-Centering in Reduced Dose Chest-CT: Impact on Effective Dose and Image Noise Values.
Eberhard M; Blüthgen C; Barth BK; Frauenfelder T; Saltybaeva N; Martini K
Acad Radiol; 2020 Apr; 27(4):508-517. PubMed ID: 31358357
[TBL] [Abstract][Full Text] [Related]
11. [Influence of Bowtie Filter and Patient Positioning on In-plane Dose Distribution and Image Quality in ECG-gated CT].
Minami K; Matsubara K; Hayashi Y; Fujiwara Y; Morimoto K; Kobatake T
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2019; 75(6):536-545. PubMed ID: 31217404
[TBL] [Abstract][Full Text] [Related]
12. The effect of head size∕shape, miscentering, and bowtie filter on peak patient tissue doses from modern brain perfusion 256-slice CT: how can we minimize the risk for deterministic effects?
Perisinakis K; Seimenis I; Tzedakis A; Papadakis AE; Damilakis J
Med Phys; 2013 Jan; 40(1):011911. PubMed ID: 23298102
[TBL] [Abstract][Full Text] [Related]
13. Radiation dose reduction, improved isocenter accuracy and CT scan time savings with automatic patient positioning by a 3D camera.
Dane B; O'Donnell T; Liu S; Vega E; Mohammed S; Singh V; Kapoor A; Megibow A
Eur J Radiol; 2021 Mar; 136():109537. PubMed ID: 33454459
[TBL] [Abstract][Full Text] [Related]
14. Optimized Camera-Based Patient Positioning in CT: Impact on Radiation Exposure.
Manava P; Galster M; Ammon J; Singer J; Lell MM; Rieger V
Invest Radiol; 2023 Feb; 58(2):126-130. PubMed ID: 35926075
[TBL] [Abstract][Full Text] [Related]
15. Effect of vertical positioning on organ dose, image noise and contrast in pediatric chest CT--phantom study.
Kaasalainen T; Palmu K; Lampinen A; Kortesniemi M
Pediatr Radiol; 2013 Jun; 43(6):673-84. PubMed ID: 23341090
[TBL] [Abstract][Full Text] [Related]
16. Vertical off-centering affects organ dose in chest CT: Evidence from Monte Carlo simulations in anthropomorphic phantoms.
Saltybaeva N; Alkadhi H
Med Phys; 2017 Nov; 44(11):5697-5704. PubMed ID: 28817195
[TBL] [Abstract][Full Text] [Related]
17. The effects of patient positioning when interpreting CT dose metrics: A phantom study.
Marsh RM; Silosky MS
Med Phys; 2017 Apr; 44(4):1514-1524. PubMed ID: 28133763
[TBL] [Abstract][Full Text] [Related]
18. Abdominal CT during pregnancy: a phantom study on the effect of patient centring on conceptus radiation dose and image quality.
Solomou G; Papadakis AE; Damilakis J
Eur Radiol; 2015 Apr; 25(4):911-21. PubMed ID: 25430006
[TBL] [Abstract][Full Text] [Related]
19. Use of a 3D camera for automated patient positioning for chest-abdomen-pelvis CT scans: Effect on positioning accuracy and patient dose.
Nelson R; Harkin S; Iball G
Radiography (Lond); 2024 Jul; 30(4):1060-1067. PubMed ID: 38733956
[TBL] [Abstract][Full Text] [Related]
20. Automated patient positioning in CT using a 3D camera for body contour detection: accuracy in pediatric patients.
Booij R; van Straten M; Wimmer A; Budde RPJ
Eur Radiol; 2021 Jan; 31(1):131-138. PubMed ID: 32749591
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]