These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 3628780)

  • 1. Focal-spot measurement: comparison of slit, pinhole, and star resolution pattern techniques.
    Everson JD; Gray JE
    Radiology; 1987 Oct; 165(1):261-4. PubMed ID: 3628780
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Measurement of focal spot in X-ray tube using imaging plate].
    Abe S; Negishi T; Fukaya M; Akiyama T; Noguchi M; Fujisaki T; Monma M; Saitoh H
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2004 Aug; 60(8):1132-8. PubMed ID: 15389171
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurement of focal spot size with slit camera using computed radiography and flat-panel based digital detectors.
    Rong XJ; Krugh KT; Shepard SJ; Geiser WR
    Med Phys; 2003 Jul; 30(7):1768-75. PubMed ID: 12906194
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Method for measuring the focal spot size of an x-ray tube using a coded aperture mask and a digital detector.
    Russo P; Mettivier G
    Med Phys; 2011 Apr; 38(4):2099-115. PubMed ID: 21626943
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [The evaluation of the performance of a new-concept screen-film system].
    Tosi G; Brambilla MG; De Crescenzo S
    Radiol Med; 1992 Nov; 84(5):641-4. PubMed ID: 1475429
    [TBL] [Abstract][Full Text] [Related]  

  • 6. X-ray tube focal spot sizes: comprehensive studies of their measurement and effect of measured size in angiography.
    Doi K; Loo LN; Chan HP
    Radiology; 1982 Jul; 144(2):383-93. PubMed ID: 7089295
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Slit camera focal spot measurement errors in mammography.
    Tang S; Barnes GT; Tanner RL
    Med Phys; 1995 Nov; 22(11 Pt 1):1803-14. PubMed ID: 8587535
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of testing of collimator and beam alignment, focal spot size with slit camera, and tube current consistency using computed radiography and conventional screen-film systems.
    Meechai T; Chousangsuntorn K; Owasirikul W; Mongkolsuk M; Iampa W
    J Appl Clin Med Phys; 2019 Jun; 20(6):160-169. PubMed ID: 31095873
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A highly accurate focal spot camera--laboratory and field model.
    Roeck WW; Milne EN
    Radiology; 1978 Jun; 127(3):779-83. PubMed ID: 663178
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of radiation dose, focal spot, and automatic exposure of newer film-screen mammography units.
    Kimme-Smith C; Bassett LW; Gold RH
    AJR Am J Roentgenol; 1987 Nov; 149(5):913-7. PubMed ID: 3499794
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Focal spot size measurements with pinhole and slit for microfocus mammography units.
    Kimme-Smith C; Bassett LW; Gold RH
    Med Phys; 1988; 15(3):298-303. PubMed ID: 3405132
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [X-ray phase imaging using a X-ray tube with a small focal spot -improvement of image quality in mammography-].
    Honda C; Ohara H; Ishisaka A; Shimada F; Endo T
    Igaku Butsuri; 2002; 22(1):21-9. PubMed ID: 12766293
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A comparative evaluation of rare-earth screen-film systems. System speed, contrast, sensitometry, RMS noise, square-wave response function, and contrast-dose-detail analysis.
    Fearon T; Vucich J; Hoe J; McSweeney WJ; Potter BM
    Invest Radiol; 1986 Aug; 21(8):654-62. PubMed ID: 3744739
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Resolution in radiographic magnification.
    Wagner LK; Cohen G; Wong WH; Amtey SR
    Med Phys; 1981; 8(3):382-4. PubMed ID: 7322061
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Focal spot measurements using a digital flat panel detector.
    Jain A; Panse A; Bednarek DR; Rudin S
    Proc SPIE Int Soc Opt Eng; 2014 Mar; 9033(90335F):. PubMed ID: 25302004
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measurement of the focal spot size of diagnostic x-ray tubes--a comparison of pinhole and resolution methods.
    Robinson A; Grimshaw GM
    Br J Radiol; 1975 Jul; 48(571):572-80. PubMed ID: 1148590
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Direct radiographic magnification: evaluation of three microfocus x-ray tubes.
    De Smet AA; Fritz SL; Templeton AW
    AJR Am J Roentgenol; 1982 Jan; 138(1):139-42. PubMed ID: 6976689
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [The system concept of a microfocus x-ray system for clinical application].
    Gebureck P; Fredow G; Sperner W
    Radiologe; 1991 Sep; 31(9):407-12. PubMed ID: 1947058
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Direct digital magnification mammography with a large-surface detector made of amorphous silicon].
    Hermann KP; Hundertmark C; Funke M; von Brenndorff A; Grabbe E
    Rofo; 1999 May; 170(5):503-6. PubMed ID: 10370416
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of radiographic image quality parameters obtained with the REX simulator.
    Magalhaes LA; Drexler GG; deAlmeida CE
    Radiat Prot Dosimetry; 2011 Nov; 147(4):614-8. PubMed ID: 21273198
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.