These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

170 related articles for article (PubMed ID: 36289267)

  • 21. A new generation of magnetoencephalography: Room temperature measurements using optically-pumped magnetometers.
    Boto E; Meyer SS; Shah V; Alem O; Knappe S; Kruger P; Fromhold TM; Lim M; Glover PM; Morris PG; Bowtell R; Barnes GR; Brookes MJ
    Neuroimage; 2017 Apr; 149():404-414. PubMed ID: 28131890
    [TBL] [Abstract][Full Text] [Related]  

  • 22. On-Scalp Optically Pumped Magnetometers versus Cryogenic Magnetoencephalography for Diagnostic Evaluation of Epilepsy in School-aged Children.
    Feys O; Corvilain P; Aeby A; Sculier C; Holmes N; Brookes M; Goldman S; Wens V; De Tiège X
    Radiology; 2022 Aug; 304(2):429-434. PubMed ID: 35503013
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A 90-channel triaxial magnetoencephalography system using optically pumped magnetometers.
    Rea M; Boto E; Holmes N; Hill R; Osborne J; Rhodes N; Leggett J; Rier L; Bowtell R; Shah V; Brookes MJ
    Ann N Y Acad Sci; 2022 Nov; 1517(1):107-124. PubMed ID: 36065147
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Measuring the cortical tracking of speech with optically-pumped magnetometers.
    de Lange P; Boto E; Holmes N; Hill RM; Bowtell R; Wens V; De Tiège X; Brookes MJ; Bourguignon M
    Neuroimage; 2021 Jun; 233():117969. PubMed ID: 33744453
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Multimodal neuroimaging with optically pumped magnetometers: A simultaneous MEG-EEG-fNIRS acquisition system.
    Ru X; He K; Lyu B; Li D; Xu W; Gu W; Ma X; Liu J; Li C; Li T; Zheng F; Yan X; Yin Y; Duan H; Na S; Wan S; Qin J; Sheng J; Gao JH
    Neuroimage; 2022 Oct; 259():119420. PubMed ID: 35777634
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Scalp attached tangential magnetoencephalography using tunnel magneto-resistive sensors.
    Kanno A; Nakasato N; Oogane M; Fujiwara K; Nakano T; Arimoto T; Matsuzaki H; Ando Y
    Sci Rep; 2022 Apr; 12(1):6106. PubMed ID: 35414691
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Optically pumped magnetometers: From quantum origins to multi-channel magnetoencephalography.
    Tierney TM; Holmes N; Mellor S; López JD; Roberts G; Hill RM; Boto E; Leggett J; Shah V; Brookes MJ; Bowtell R; Barnes GR
    Neuroimage; 2019 Oct; 199():598-608. PubMed ID: 31141737
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Measuring functional connectivity with wearable MEG.
    Boto E; Hill RM; Rea M; Holmes N; Seedat ZA; Leggett J; Shah V; Osborne J; Bowtell R; Brookes MJ
    Neuroimage; 2021 Apr; 230():117815. PubMed ID: 33524584
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Cross-Axis Dynamic Field Compensation of Optically Pumped Magnetometer Arrays for MEG.
    Robinson SE; Andonegui AB; Holroyd T; Hughes KJ; Alem O; Knappe S; Maydew T; Griesshammer A; Nugent A
    Neuroimage; 2022 Nov; 262():119559. PubMed ID: 35970471
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Requirements for Coregistration Accuracy in On-Scalp MEG.
    Zetter R; Iivanainen J; Stenroos M; Parkkonen L
    Brain Topogr; 2018 Nov; 31(6):931-948. PubMed ID: 29934728
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Practical real-time MEG-based neural interfacing with optically pumped magnetometers.
    Wittevrongel B; Holmes N; Boto E; Hill R; Rea M; Libert A; Khachatryan E; Van Hulle MM; Bowtell R; Brookes MJ
    BMC Biol; 2021 Aug; 19(1):158. PubMed ID: 34376215
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Using OPM-MEG in contrasting magnetic environments.
    Hill RM; Devasagayam J; Holmes N; Boto E; Shah V; Osborne J; Safar K; Worcester F; Mariani C; Dawson E; Woolger D; Bowtell R; Taylor MJ; Brookes MJ
    Neuroimage; 2022 Jun; 253():119084. PubMed ID: 35278706
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Calibration and Localization of Optically Pumped Magnetometers Using Electromagnetic Coils.
    Iivanainen J; Borna A; Zetter R; Carter TR; Stephen JM; McKay J; Parkkonen L; Taulu S; Schwindt PDD
    Sensors (Basel); 2022 Apr; 22(8):. PubMed ID: 35459044
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Optimising the sensing volume of OPM sensors for MEG source reconstruction.
    Bezsudnova Y; Koponen LM; Barontini G; Jensen O; Kowalczyk AU
    Neuroimage; 2022 Dec; 264():119747. PubMed ID: 36403733
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Beginnings of the Development of Magnetoencephalography Systems Using Superconducting and Spintronics Sensors].
    Nakasato N
    Brain Nerve; 2022 Nov; 74(11):1295-1301. PubMed ID: 36343935
    [TBL] [Abstract][Full Text] [Related]  

  • 36. BabyMEG: A whole-head pediatric magnetoencephalography system for human brain development research.
    Okada Y; Hämäläinen M; Pratt K; Mascarenas A; Miller P; Han M; Robles J; Cavallini A; Power B; Sieng K; Sun L; Lew S; Doshi C; Ahtam B; Dinh C; Esch L; Grant E; Nummenmaa A; Paulson D
    Rev Sci Instrum; 2016 Sep; 87(9):094301. PubMed ID: 27782541
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Reducing crosstalk in optically-pumped magnetometer arrays.
    Nardelli NV; Krzyzewski SP; Knappe SA
    Phys Med Biol; 2019 Nov; 64(21):21NT03. PubMed ID: 31593936
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Theoretical advantages of a triaxial optically pumped magnetometer magnetoencephalography system.
    Brookes MJ; Boto E; Rea M; Shah V; Osborne J; Holmes N; Hill RM; Leggett J; Rhodes N; Bowtell R
    Neuroimage; 2021 Aug; 236():118025. PubMed ID: 33838266
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Localizing on-scalp MEG sensors using an array of magnetic dipole coils.
    Pfeiffer C; Andersen LM; Lundqvist D; Hämäläinen M; Schneiderman JF; Oostenveld R
    PLoS One; 2018; 13(5):e0191111. PubMed ID: 29746486
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Wearable OPM-MEG: A changing landscape for epilepsy.
    Pedersen M; Abbott DF; Jackson GD
    Epilepsia; 2022 Nov; 63(11):2745-2753. PubMed ID: 35841260
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.