These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

184 related articles for article (PubMed ID: 36289443)

  • 1. Multiple mechanisms contribute to fluorometry signals from the voltage-gated proton channel.
    Papp F; Toombes GES; Pethő Z; Bagosi A; Feher A; Almássy J; Borrego J; Kuki Á; Kéki S; Panyi G; Varga Z
    Commun Biol; 2022 Oct; 5(1):1131. PubMed ID: 36289443
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A synthetic flavonoid derivate in the plasma membrane transforms the voltage-clamp fluorometry signal of CiHv1.
    Pethő Z; Pajtás D; Piga M; Magyar Z; Zakany F; Kovacs T; Zidar N; Panyi G; Varga Z; Papp F
    FEBS J; 2024 Jun; 291(11):2354-2371. PubMed ID: 38431775
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Molecular mechanism of Zn2+ inhibition of a voltage-gated proton channel.
    Qiu F; Chamberlin A; Watkins BM; Ionescu A; Perez ME; Barro-Soria R; González C; Noskov SY; Larsson HP
    Proc Natl Acad Sci U S A; 2016 Oct; 113(40):E5962-E5971. PubMed ID: 27647906
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Gating charge displacement in a monomeric voltage-gated proton (H
    Carmona EM; Larsson HP; Neely A; Alvarez O; Latorre R; Gonzalez C
    Proc Natl Acad Sci U S A; 2018 Sep; 115(37):9240-9245. PubMed ID: 30127012
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Functional Site-Directed Fluorometry.
    Priest M; Bezanilla F
    Adv Exp Med Biol; 2015; 869():55-76. PubMed ID: 26381940
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Hydrophobic gasket mutation produces gating pore currents in closed human voltage-gated proton channels.
    Banh R; Cherny VV; Morgan D; Musset B; Thomas S; Kulleperuma K; Smith SME; Pomès R; DeCoursey TE
    Proc Natl Acad Sci U S A; 2019 Sep; 116(38):18951-18961. PubMed ID: 31462498
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Subunit interactions during cooperative opening of voltage-gated proton channels.
    Qiu F; Rebolledo S; Gonzalez C; Larsson HP
    Neuron; 2013 Jan; 77(2):288-98. PubMed ID: 23352165
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mapping of sites facing aqueous environment of voltage-gated proton channel at resting state: a study with PEGylation protection.
    Kurokawa T; Okamura Y
    Biochim Biophys Acta; 2014 Jan; 1838(1 Pt B):382-7. PubMed ID: 24140009
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Voltage-gated proton (H(v)1) channels, a singular voltage sensing domain.
    Castillo K; Pupo A; Baez-Nieto D; Contreras GF; Morera FJ; Neely A; Latorre R; Gonzalez C
    FEBS Lett; 2015 Nov; 589(22):3471-8. PubMed ID: 26296320
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Analysis of an electrostatic mechanism for ΔpH dependent gating of the voltage-gated proton channel, H
    Sokolov VS; Cherny VV; Ayuyan AG; DeCoursey TE
    Biochim Biophys Acta Bioenerg; 2021 Nov; 1862(11):148480. PubMed ID: 34363792
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Activation-pathway transitions in human voltage-gated proton channels revealed by a non-canonical fluorescent amino acid.
    Suárez-Delgado E; Orozco-Contreras M; Rangel-Yescas GE; Islas LD
    Elife; 2023 Jan; 12():. PubMed ID: 36695566
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dimer interaction in the Hv1 proton channel.
    Mony L; Stroebel D; Isacoff EY
    Proc Natl Acad Sci U S A; 2020 Aug; 117(34):20898-20907. PubMed ID: 32788354
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Voltage Clamp Fluorometry: Illuminating the Dynamics of Ion Channels.
    Sastre D; Fedida D
    Methods Mol Biol; 2024; 2796():119-138. PubMed ID: 38856899
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Currents through Hv1 channels deplete protons in their vicinity.
    De-la-Rosa V; Suárez-Delgado E; Rangel-Yescas GE; Islas LD
    J Gen Physiol; 2016 Feb; 147(2):127-36. PubMed ID: 26809792
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Architecture and gating of Hv1 proton channels.
    Tombola F; Ulbrich MH; Isacoff EY
    J Physiol; 2009 Nov; 587(Pt 22):5325-9. PubMed ID: 19915215
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A specialized molecular motion opens the Hv1 voltage-gated proton channel.
    Mony L; Berger TK; Isacoff EY
    Nat Struct Mol Biol; 2015 Apr; 22(4):283-290. PubMed ID: 25730777
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Structural dynamics determine voltage and pH gating in human voltage-gated proton channel.
    Han S; Peng S; Vance J; Tran K; Do N; Bui N; Gui Z; Wang S
    Elife; 2022 Mar; 11():. PubMed ID: 35244539
    [No Abstract]   [Full Text] [Related]  

  • 18. Hydrophobic plug functions as a gate in voltage-gated proton channels.
    Chamberlin A; Qiu F; Rebolledo S; Wang Y; Noskov SY; Larsson HP
    Proc Natl Acad Sci U S A; 2014 Jan; 111(2):E273-82. PubMed ID: 24379371
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The opening of the two pores of the Hv1 voltage-gated proton channel is tuned by cooperativity.
    Tombola F; Ulbrich MH; Kohout SC; Isacoff EY
    Nat Struct Mol Biol; 2010 Jan; 17(1):44-50. PubMed ID: 20023640
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Voltage-clamp fluorometry for advancing mechanistic understanding of ion channel mechanisms with a focus on acid-sensing ion channels.
    Centonze E; Kellenberger S
    Biochem Soc Trans; 2024 Oct; 52(5):2167-2177. PubMed ID: 39400205
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.