  • 1. Partial Obstruction of Ventricular Catheters Affects Performance in a New Catheter Obstruction Model of Hydrocephalus.
    Lee S; Vinzani M; Romero B; Chan AY; Castañeyra-Ruiz L; Muhonen M
    Children (Basel); 2022 Sep; 9(10):. PubMed ID: 36291388
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Polyvinylpyrrolidone-Coated Catheters Decrease Astrocyte Adhesion and Improve Flow/Pressure Performance in an Invitro Model of Hydrocephalus.
    Castañeyra-Ruiz L; Lee S; Chan AY; Shah V; Romero B; Ledbetter J; Muhonen M
    Children (Basel); 2022 Dec; 10(1):. PubMed ID: 36670569
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Polyvinylpyrrolidone-coated catheters decrease choroid plexus adhesion and improve flow/pressure performance in an in vitro model of hydrocephalus.
    Lee S; Ledbetter J; Davies J; Romero B; Muhonen M; Castaneyra-Ruiz L
    Childs Nerv Syst; 2024 Jan; 40(1):115-121. PubMed ID: 37417983
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Simulation of proximal catheter occlusion and design of a shunt tap aspiration system.
    Olson E; Garst J; Blank J; Abbott H; Shaffer A; Anderson Z; Nair K; Lin J
    Childs Nerv Syst; 2021 Mar; 37(3):895-901. PubMed ID: 33029728
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Flow characteristics of cerebrospinal fluid shunt tubing.
    Cheatle JT; Bowder AN; Agrawal SK; Sather MD; Hellbusch LC
    J Neurosurg Pediatr; 2012 Feb; 9(2):191-7. PubMed ID: 22295926
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dual catheter and double-lumen cerebrospinal fluid shunt systems with backflow mechanisms.
    Patel A; Qi D; Boyle J; Morris M; Lin J
    Childs Nerv Syst; 2024 Jan; 40(1):135-143. PubMed ID: 37515721
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Flow ventricular catheters for shunted hydrocephalus: initial clinical results.
    Galarza M; Etus V; Sosa F; Argañaraz R; Mantese B; Gazzeri R; Montoya CG; de la Rosa P; Guerrero AL; Chaban G; Giménez Á; Amigó JM
    Childs Nerv Syst; 2021 Mar; 37(3):903-911. PubMed ID: 33123821
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Perforation holes in ventricular catheters--is less more?
    Thomale UW; Hosch H; Koch A; Schulz M; Stoltenburg G; Haberl EJ; Sprung C
    Childs Nerv Syst; 2010 Jun; 26(6):781-9. PubMed ID: 20024658
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Proximal ventricular shunt catheter occlusion model.
    Qi D; Patel A; Dunwoody R; McCall S; Bach S; Lin J
    Childs Nerv Syst; 2023 Jan; 39(1):205-210. PubMed ID: 36169702
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Recanalization of obstructed cerebrospinal fluid ventricular catheters using ultrasonic cavitation.
    Ginsberg HJ; Drake JM; Peterson TM; Cobbold RS
    Neurosurgery; 2006 Oct; 59(4 Suppl 2):ONS403-12; discussion ONS412. PubMed ID: 17041510
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Computational and experimental study of proximal flow in ventricular catheters. Technical note.
    Lin J; Morris M; Olivero W; Boop F; Sanford RA
    J Neurosurg; 2003 Aug; 99(2):426-31. PubMed ID: 12924722
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Toward a better understanding of the cellular basis for cerebrospinal fluid shunt obstruction: report on the construction of a bank of explanted hydrocephalus devices.
    Hanak BW; Ross EF; Harris CA; Browd SR; Shain W
    J Neurosurg Pediatr; 2016 Aug; 18(2):213-23. PubMed ID: 27035548
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of Protein Concentration on the Flow of Cerebrospinal Fluid Through Shunt Tubing.
    Cheatle JT; Bowder AN; Tefft JL; Agrawal SK; Hellbusch LC
    Neurosurgery; 2015 Dec; 77(6):972-8. PubMed ID: 26270195
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Computational fluid dynamics of ventricular catheters used for the treatment of hydrocephalus: a 3D analysis.
    Galarza M; Giménez Á; Valero J; Pellicer OP; Amigó JM
    Childs Nerv Syst; 2014 Jan; 30(1):105-16. PubMed ID: 23881424
    [TBL] [Abstract][Full Text] [Related]  

  • 15. New designs of ventricular catheters for hydrocephalus by 3-D computational fluid dynamics.
    Galarza M; Giménez Á; Pellicer O; Valero J; Amigó JM
    Childs Nerv Syst; 2015 Jan; 31(1):37-48. PubMed ID: 25096070
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Next generation of ventricular catheters for hydrocephalus based on parametric designs.
    Galarza M; Giménez A; Amigó JM; Schuhmann M; Gazzeri R; Thomale U; McAllister JP
    Childs Nerv Syst; 2018 Feb; 34(2):267-276. PubMed ID: 28812141
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of the hole geometry on the flow distribution in ventricular catheters for hydrocephalus.
    Giménez Á; Galarza M; Pellicer O; Valero J; Amigó JM
    Biomed Eng Online; 2016 Jul; 15 Suppl 1(Suppl 1):71. PubMed ID: 27455059
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Initial experience with silver-impregnated polyurethane ventricular catheter for shunting of cerebrospinal fluid in patients with infected hydrocephalus.
    Izci Y; Secer H; Akay C; Gonul E
    Neurol Res; 2009 Apr; 31(3):234-7. PubMed ID: 19040800
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pathophysiology of shunt dysfunction in shunt treated hydrocephalus.
    Blegvad C; Skjolding AD; Broholm H; Laursen H; Juhler M
    Acta Neurochir (Wien); 2013 Sep; 155(9):1763-72. PubMed ID: 23645322
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Parametric study of ventricular catheters for hydrocephalus.
    Galarza M; Giménez A; Pellicer O; Valero J; Amigó JM
    Acta Neurochir (Wien); 2016 Jan; 158(1):109-15; discussion 115-6. PubMed ID: 26530709