BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

158 related articles for article (PubMed ID: 36294340)

  • 1. Endoscopic Bridge-and-Seal of Bile Leaks Using a Fully Covered Self-Expandable Metallic Stent above the Papilla.
    Fukuda K; Nakai Y; Mizuno S; Sato T; Noguchi K; Kanai S; Suzuki T; Hakuta R; Ishigaki K; Saito K; Saito T; Takahara N; Hamada T; Kogure H; Fujishiro M
    J Clin Med; 2022 Oct; 11(20):. PubMed ID: 36294340
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of fully covered self-expanding metal stents in benign biliary strictures and bile leaks.
    Lalezari D; Singh I; Reicher S; Eysselein VE
    World J Gastrointest Endosc; 2013 Jul; 5(7):332-9. PubMed ID: 23858377
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Should a fully covered self-expandable biliary metal stent be anchored with a double-pigtail plastic stent? A retrospective study.
    Emhmed Ali S; Frandah WM; Su L; Fielding C; Mardini H
    World J Gastrointest Endosc; 2019 May; 11(5):365-372. PubMed ID: 31205597
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A non-randomized study in consecutive patients with postcholecystectomy refractory biliary leaks who were managed endoscopically with the use of multiple plastic stents or fully covered self-expandable metal stents (with videos).
    Canena J; Liberato M; Meireles L; Marques I; Romão C; Coutinho AP; Neves BC; Veiga PM
    Gastrointest Endosc; 2015 Jul; 82(1):70-8. PubMed ID: 25771064
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Short-term stenting using fully covered self-expandable metal stents for treatment of refractory biliary leaks, postsphincterotomy bleeding, and perforations.
    Canena J; Liberato M; Horta D; Romão C; Coutinho A
    Surg Endosc; 2013 Jan; 27(1):313-24. PubMed ID: 22806507
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Feasibility of placing a modified fully covered self-expandable metal stent above the papilla to minimize stent-induced bile duct injury in patients with refractory benign biliary strictures (with videos).
    Moon JH; Choi HJ; Koo HC; Han SH; Lee TH; Cho YD; Park SH; Kim SJ
    Gastrointest Endosc; 2012 May; 75(5):1080-5. PubMed ID: 22401821
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Endoscopic therapy using a self-expandable metallic stent with an anti-migration system for postorthotopic liver transplantation anastomotic biliary stricture.
    Pinheiro LW; Martins FP; De Paulo GA; Contini MLC; Ferrari AP; Della Libera E
    World J Gastrointest Endosc; 2022 Sep; 14(9):547-554. PubMed ID: 36186946
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Elevated stricture rate following the use of fully covered self-expandable metal biliary stents for biliary leaks following liver transplantation.
    Phillips MS; Bonatti H; Sauer BG; Smith L; Javaid M; Kahaleh M; Schmitt T
    Endoscopy; 2011 Jun; 43(6):512-7. PubMed ID: 21618151
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Risk of pancreatitis following endoscopically placed large-bore plastic biliary stents with and without biliary sphincterotomy for management of postoperative bile leaks.
    Simmons DT; Petersen BT; Gostout CJ; Levy MJ; Topazian MD; Baron TH
    Surg Endosc; 2008 Jun; 22(6):1459-63. PubMed ID: 18027045
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Usefulness of Intraductal Placement of a Dumbbell-Shaped Fully Covered Self-Expandable Metal Stent for Post-Cholecystectomy Bile Leaks.
    Nakagawa K; Matsubara S; Suda K; Otsuka T; Oka M; Nagoshi S
    J Clin Med; 2023 Oct; 12(20):. PubMed ID: 37892668
    [No Abstract]   [Full Text] [Related]  

  • 11. A US Multicenter Study of Safety and Efficacy of Fully Covered Self-Expandable Metallic Stents in Benign Extrahepatic Biliary Strictures.
    Saxena P; Diehl DL; Kumbhari V; Shieh F; Buscaglia JM; Sze W; Kapoor S; Komanduri S; Nasr J; Shin EJ; Singh V; Lennon AM; Kalloo AN; Khashab MA
    Dig Dis Sci; 2015 Nov; 60(11):3442-8. PubMed ID: 25850628
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Clinical efficacy of anti-migration features in fully covered metallic stents for anastomotic biliary strictures after liver transplantation: comparison of conventional and anti-migration stents.
    Bordaçahar B; Perdigao F; Leblanc S; Barret M; Duchmann JC; Guillaumot MA; Chaussade S; Scatton O; Prat F
    Gastrointest Endosc; 2018 Oct; 88(4):655-664. PubMed ID: 30003877
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Modified fully covered self-expandable metal stents with antimigration features for benign pancreatic-duct strictures in advanced chronic pancreatitis, with a focus on the safety profile and reducing migration.
    Moon SH; Kim MH; Park DH; Song TJ; Eum J; Lee SS; Seo DW; Lee SK
    Gastrointest Endosc; 2010 Jul; 72(1):86-91. PubMed ID: 20493483
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the Feasibility and Effectiveness of Placement of Fully Covered Self-Expandable Metallic Stents via Various Insertion Routes for Benign Biliary Strictures.
    Tomishima K; Ishii S; Fujisawa T; Ikemura M; Ushio M; Takahashi S; Yamagata W; Takasaki Y; Suzuki A; Ito K; Haga K; Ochiai K; Nomura O; Saito H; Shibuya T; Nagahara A; Isayama H
    J Clin Med; 2021 May; 10(11):. PubMed ID: 34071678
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Outcomes of endoscopic management of primary and refractory postcholecystectomy biliary leaks in a multicentre review of 178 patients.
    Canena J; Horta D; Coimbra J; Meireles L; Russo P; Marques I; Ricardo L; Rodrigues C; Capela T; Carvalho D; Loureiro R; Dias AM; Ramos G; Coutinho AP; Romão C; Veiga PM
    BMC Gastroenterol; 2015 Aug; 15():105. PubMed ID: 26285593
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Feasibility of the placement of a novel 6-mm diameter threaded fully covered self-expandable metal stent for malignant hilar biliary obstructions (with videos).
    Inoue T; Okumura F; Naitoh I; Fukusada S; Kachi K; Ozeki T; Anbe K; Iwasaki H; Mizushima T; Kobayashi Y; Ishii N; Ito K; Kondo H; Hayashi K; Yoneda M; Sano H
    Gastrointest Endosc; 2016 Aug; 84(2):352-7. PubMed ID: 27060713
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Feasibility and safety of placement of a newly designed, fully covered self-expandable metal stent for refractory benign pancreatic ductal strictures: a pilot study (with video).
    Park DH; Kim MH; Moon SH; Lee SS; Seo DW; Lee SK
    Gastrointest Endosc; 2008 Dec; 68(6):1182-9. PubMed ID: 19028228
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Self-Expandable Metallic Stent Is More Cost Efficient Than Plastic Stent in Treating Anastomotic Biliary Stricture.
    Jang S; Stevens T; Lopez R; Chahal P; Bhatt A; Sanaka M; Vargo JJ
    Dig Dis Sci; 2020 Feb; 65(2):600-608. PubMed ID: 31104197
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Prolonged patency of fully covered self-expandable metal stents with an externally anchored plastic stent in distal malignant biliary obstruction.
    Chun JW; Woo SM; Han M; Lee MW; Choi JH; Cho IR; Paik WH; Lee WJ; Ryu JK; Kim YT; Lee SH
    Endoscopy; 2023 Jun; 55(6):563-568. PubMed ID: 36736351
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of a newly modified nonflared fully covered metal stent, 12 mm in diameter, for intraductal placement in patients with malignant biliary strictures: a feasibility study.
    Choi HJ; Moon JH; Lee YN; Kim HS; Choi MH; Lee TH; Cha SW; Cho YD; Park SH; Kim SJ
    Endoscopy; 2016 Jul; 48(7):625-31. PubMed ID: 27110694
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.