These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 36296068)

  • 21. Eco-Friendly Highly Sensitive Transducers Based on a New KNN-NTK-FM Lead-Free Piezoelectric Ceramic for High-Frequency Biomedical Ultrasonic Imaging Applications.
    Chen R; Jiang L; Zhang T; Matsuoka T; Yamazaki M; Qian X; Lu G; Safari A; Zhu J; Shung KK; Ma T; Zhou Q
    IEEE Trans Biomed Eng; 2019 Jun; 66(6):1580-1587. PubMed ID: 30452346
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Air-Coupled Ultrasonic Receivers with High Electromechanical Coupling PMN-32%PT Strip-Like Piezoelectric Elements.
    Kazys RJ; Sliteris R; Sestoke J
    Sensors (Basel); 2017 Oct; 17(10):. PubMed ID: 29035348
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Design and Micro-Fabrication of Focused High-Frequency Needle Transducers for Medical Imaging.
    Nguyen TP; Choi J; Nguyen VT; Mondal S; Bui NT; Vu DD; Park S; Oh J
    Sensors (Basel); 2022 May; 22(10):. PubMed ID: 35632172
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Multiple matching scheme for broadband 0.72Pb(Mg(13)Nb(23))O(3)-0.28PbTiO(3) single crystal phased-array transducer.
    Lau ST; Li H; Wong KS; Zhou QF; Zhou D; Li YC; Luo HS; Shung KK; Dai JY
    J Appl Phys; 2009 May; 105(9):94908. PubMed ID: 19657405
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Piezoelectric single crystals for ultrasonic transducers in biomedical applications.
    Zhou Q; Lam KH; Zheng H; Qiu W; Shung KK
    Prog Mater Sci; 2014 Oct; 66():87-111. PubMed ID: 25386032
    [TBL] [Abstract][Full Text] [Related]  

  • 26. 20-MHz phased array ultrasound transducer for in vivo ultrasound imaging of small animals.
    Wong CM; Chan SF; Liu R; Zhang J; Wu WC; Liang Z; Yau HM; Wang DY; Li S; Lam KH; Qiu WB; Luo HS; Dai JY
    Ultrasonics; 2022 Dec; 126():106821. PubMed ID: 35988512
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Micromachining of High-Quality PMN-PT/Epoxy 1-3 Composite for High-Frequency (>30 MHz) Ultrasonic Transducer Applications.
    Lei Z; Xu G; Liu J; Liu Y; Ji X
    IEEE Trans Ultrason Ferroelectr Freq Control; 2023 Nov; 70(11):1563-1573. PubMed ID: 37773915
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The application of high permittivity piezoelectric ceramics to 2D array transducers for medical imaging.
    Felix N; Tran-Huu-Hue LP; Walker L; Millar C; Lethiecq M
    Ultrasonics; 2000 Mar; 38(1-8):127-30. PubMed ID: 10829643
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Design considerations for piezoelectric polymer ultrasound transducers.
    Brown LF
    IEEE Trans Ultrason Ferroelectr Freq Control; 2000; 47(6):1377-96. PubMed ID: 18238684
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Development of a KNN Ceramic-Based Lead-Free Linear Array Ultrasonic Transducer.
    Zhang Z; Chen R; Wang B; Zhang T; Su M; Liu R; Yang J; Cao X; Li Y; Zheng H; Shung KK; Humayun MS; Zhou Q; Qiu W
    IEEE Trans Ultrason Ferroelectr Freq Control; 2018 Nov; 65(11):2113-2120. PubMed ID: 30183624
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Mass-spring matching layers for high-frequency ultrasound transducers: a new technique using vacuum deposition.
    Brown J; Sharma S; Leadbetter J; Cochran S; Adamson R
    IEEE Trans Ultrason Ferroelectr Freq Control; 2014 Nov; 61(11):1911-21. PubMed ID: 25389169
    [TBL] [Abstract][Full Text] [Related]  

  • 32. PMN-PT single crystal thick films on silicon substrate for high-frequency micromachined ultrasonic transducers.
    Peng J; Lau ST; Chao C; Dai JY; Chan HL; Luo HS; Zhu BP; Zhou QF; Shung KK
    Appl Phys A Mater Sci Process; 2008 Nov; 2008():161-163. PubMed ID: 20953269
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Experimental analysis of 1-3 piezocomposites for high-intensity focused ultrasound transducer applications.
    Chen GS; Liu HC; Lin YC; Lin YL
    IEEE Trans Biomed Eng; 2013 Jan; 60(1):128-34. PubMed ID: 23193224
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Ultrasound-gated computed tomography coronary angiography: Development of ultrasound transducers with improved computed tomography compatibility.
    Strassle Rojas S; Collins GC; Tridandapani S; Lindsey BD
    Med Phys; 2021 Aug; 48(8):4191-4204. PubMed ID: 34087004
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Micromachined PIN-PMN-PT crystal composite transducer for high-frequency intravascular ultrasound (IVUS) imaging.
    Li X; Ma T; Tian J; Han P; Zhou Q; Shung KK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2014 Jul; 61(7):1171-8. PubMed ID: 24960706
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Broadband Ultrasonic Array Transducer From Multilayer Piezoelectric Ceramic With Lowered Co-Firing Temperature.
    Ke Q; Liew WH; Zhang L; Tan CKI; Jiang C; Yao K
    IEEE Trans Ultrason Ferroelectr Freq Control; 2020 May; 67(5):968-974. PubMed ID: 31841404
    [TBL] [Abstract][Full Text] [Related]  

  • 37. 80-MHz intravascular ultrasound transducer using PMN-PT free-standing film.
    Li X; Wu W; Chung Y; Shih WY; Shih WH; Zhou Q; Shung KK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Nov; 58(11):2281-8. PubMed ID: 22083761
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Crosstalk reduction for high-frequency linear-array ultrasound transducers using 1-3 piezocomposites with pseudo-random pillars.
    Yang HC; Cannata J; Williams J; Shung KK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2012 Oct; 59(10):2312-21. PubMed ID: 23143580
    [TBL] [Abstract][Full Text] [Related]  

  • 39. High performance relaxor-based ferroelectric single crystals for ultrasonic transducer applications.
    Chen Y; Lam KH; Zhou D; Yue Q; Yu Y; Wu J; Qiu W; Sun L; Zhang C; Luo H; Chan HL; Dai J
    Sensors (Basel); 2014 Jul; 14(8):13730-58. PubMed ID: 25076222
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Lead-Free Ultrasonic Phased Array Transducer for Human Heart Imaging.
    Ma X; Liu Y; Ruan J; Tao C; Yuan J; Chang Y; Cao W
    IEEE Trans Ultrason Ferroelectr Freq Control; 2022 Feb; 69(2):751-760. PubMed ID: 34662277
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.