These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 36298397)

  • 1. NiTi SMA Superelastic Micro Cables: Thermomechanical Behavior and Fatigue Life under Dynamic Loadings.
    Silva PCS; Grassi END; Araújo CJ; Delgado JMPQ; Lima AGB
    Sensors (Basel); 2022 Oct; 22(20):. PubMed ID: 36298397
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Critical Frequency of Self-Heating in a Superelastic Ni-Ti Belleville Spring: Experimental Characterization and Numerical Simulation.
    de Souza EF; da Silva PCS; Grassi END; de Araújo CJ; de Lima AGB
    Sensors (Basel); 2021 Oct; 21(21):. PubMed ID: 34770446
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fatigue properties of superelastic Ti-Ni filaments and braided cables for bone fixation.
    Baril Y; Brailovski V
    J Biomed Mater Res B Appl Biomater; 2010 Feb; 92(2):489-98. PubMed ID: 19957361
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of environment on fatigue failure of controlled memory wire nickel-titanium rotary instruments.
    Shen Y; Qian W; Abtin H; Gao Y; Haapasalo M
    J Endod; 2012 Mar; 38(3):376-80. PubMed ID: 22341078
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Investigation of Mechanical Properties of Large Shape Memory Alloy Bars under Different Heat Treatments.
    Kang L; Qian H; Guo Y; Ye C; Li Z
    Materials (Basel); 2020 Aug; 13(17):. PubMed ID: 32846946
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Environmental fatigue of superelastic NiTi wire with two surface finishes.
    Racek J; Šittner P
    J Mech Behav Biomed Mater; 2020 Nov; 111():104028. PubMed ID: 32818770
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Studies on new superelastic NiTi orthodontic wire. (Part 1) Tensile and bend test (author's transl)].
    Watanabe K
    Shika Rikogaku Zasshi; 1982 Jan; 23(61):47-57. PubMed ID: 6951898
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparative mechanical properties of spinal cable and wire fixation systems.
    Dickman CA; Papadopoulos SM; Crawford NR; Brantley AG; Gealer RL
    Spine (Phila Pa 1976); 1997 Mar; 22(6):596-604. PubMed ID: 9089931
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of the impact of raw materials on the fatigue and mechanical properties of ProFile Vortex rotary instruments.
    Gao Y; Gutmann JL; Wilkinson K; Maxwell R; Ammon D
    J Endod; 2012 Mar; 38(3):398-401. PubMed ID: 22341083
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Metallurgical characterization of M-Wire nickel-titanium shape memory alloy used for endodontic rotary instruments during low-cycle fatigue.
    Ye J; Gao Y
    J Endod; 2012 Jan; 38(1):105-7. PubMed ID: 22152631
    [TBL] [Abstract][Full Text] [Related]  

  • 11. New thermomechanically treated NiTi alloys - a review.
    Zupanc J; Vahdat-Pajouh N; Schäfer E
    Int Endod J; 2018 Oct; 51(10):1088-1103. PubMed ID: 29574784
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of hydrogen on super-elastic behavior of NiTi shape memory alloy wires: Experimental observation and diffusional-mechanically coupled constitutive model.
    Jiang HM; Yu C; Kan Q; Xu B; Ma C; Kang G
    J Mech Behav Biomed Mater; 2022 Aug; 132():105276. PubMed ID: 35642861
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of severe grain refinement on the damage tolerance of a superelastic NiTi shape memory alloy.
    Leitner T; Sabirov I; Pippan R; Hohenwarter A
    J Mech Behav Biomed Mater; 2017 Jul; 71():337-348. PubMed ID: 28399494
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fatigue failure of as-received and retrieved NiTi orthodontic archwires.
    Bourauel C; Scharold W; Jäger A; Eliades T
    Dent Mater; 2008 Aug; 24(8):1095-101. PubMed ID: 18289660
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Current challenges and concepts of the thermomechanical treatment of nickel-titanium instruments.
    Shen Y; Zhou HM; Zheng YF; Peng B; Haapasalo M
    J Endod; 2013 Feb; 39(2):163-72. PubMed ID: 23321225
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Design and fabrication of a bending rotation fatigue test rig for in situ electrochemical analysis during fatigue testing of NiTi shape memory alloy wires.
    Neelakantan L; Zglinski JK; Frotscher M; Eggeler G
    Rev Sci Instrum; 2013 Mar; 84(3):035102. PubMed ID: 23556847
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Thermomechanical Characterization and Modeling of NiTi Shape Memory Alloy Coil Spring.
    Puente-Córdova JG; Rentería-Baltiérrez FY; Diabb-Zavala JM; Mohamed-Noriega N; Bello-Gómez MA; Luna-Martínez JF
    Materials (Basel); 2023 May; 16(10):. PubMed ID: 37241299
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Investigation of the Thermomechanical Response of Cyclically Loaded NiTi Alloys by Means of Temperature Frequency Domain Analyses.
    Di Leonardo S; Cappello R; Burriesci G; Pitarresi G
    Materials (Basel); 2021 Dec; 14(24):. PubMed ID: 34947460
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Torsional whole-life transformation ratchetting under pure-torsional and non-proportional multiaxial cyclic loadings of NiTi SMA at human-body temperature: Experimental observations and life-prediction model.
    Song D; Kang G; Yu C; Kan Q; Zhang C
    J Mech Behav Biomed Mater; 2019 Jun; 94():267-278. PubMed ID: 30933835
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mechanical behavior of M-Wire and conventional NiTi wire used to manufacture rotary endodontic instruments.
    Pereira ES; Gomes RO; Leroy AM; Singh R; Peters OA; Bahia MG; Buono VT
    Dent Mater; 2013 Dec; 29(12):e318-24. PubMed ID: 24183054
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.