These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

61 related articles for article (PubMed ID: 36310734)

  • 1. Procedure and Aortic Remodeling Effects of Entry Closure with Stentgraft for Type B Aortic Dissection: Comparison between the Patients with Narrow True Lumen and Those with Aneurysmal Dilated False Lumen.
    Aoki A; Maruta K; Masuda T; Omoto T
    Ann Vasc Dis; 2022 Sep; 15(3):175-185. PubMed ID: 36310734
    [No Abstract]   [Full Text] [Related]  

  • 2. Retrograde type A aortic dissection during or after thoracic endovascular aortic repair: a single center 16-year experience.
    Wang GQ; Qin YF; Shi ST; Zhang KW; Zhai ST; Li TX
    Front Cardiovasc Med; 2023; 10():1160142. PubMed ID: 37547252
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Entry Site Is Associated With Aortic Enlargement After Pre-emptive Endovascular Repair for Uncomplicated Type B Aortic Dissection.
    Cho T; Uchida K; Yasuda S; Izubuchi R; Kaneko S; Matsumoto A; Ikematsu M; Kakuta S
    J Endovasc Ther; 2023 Mar; ():15266028231161224. PubMed ID: 36927098
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Predictors of aortic growth in uncomplicated type B aortic dissection from the Acute Dissection Stent Grafting or Best Medical Treatment (ADSORB) database.
    Kamman AV; Brunkwall J; Verhoeven EL; Heijmen RH; Trimarchi S;
    J Vasc Surg; 2017 Apr; 65(4):964-971.e3. PubMed ID: 27876516
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Initial experience with a modified "candy-plug" technique for false lumen embolization in chronic type B aortic dissection.
    Miles D; Arbabi C; McMackin K; Tjaden B; Schonefeld S; Baril D; Gupta N; Gewertz B; Azizzadeh A
    J Vasc Surg Cases Innov Tech; 2023 Jun; 9(2):101075. PubMed ID: 37152918
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Looping wire technique to facilitate true lumen wiring during TEVAR in type B aortic dissection with aneurysmal degeneration: A case report.
    Adiarto S; Siddiq T; Indriani S; Andriantoro H; Dakota I
    Int J Surg Case Rep; 2022 Feb; 91():106776. PubMed ID: 35065398
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Total Arch and Descending Aorta Replacement for Retrograde Type A Aortic Dissection After Endovascular Stent Graft Replacement for Complicated Type B Aortic Dissection.
    Ishibashi K; Motokawa M
    Cureus; 2019 Jun; 11(6):e5017. PubMed ID: 31497447
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Reintervention after Thoracic Endovascular Aortic Repair of Uncomplicated Type B Aortic Dissection.
    Cheng L; Xiang D; Zhang S; Zheng C; Wu X
    J Clin Med; 2023 Feb; 12(4):. PubMed ID: 36835969
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Thoracic endovascular aortic repair with true-false-true lumen deployment.
    Mansukhani NA; Chia MC; Wallace GA; Hoel AW; Eskandari MK
    J Vasc Surg Cases Innov Tech; 2020 Jun; 6(2):254-258. PubMed ID: 32490298
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Aortic remodeling, reintervention, and survival after zone 0 arch repair with frozen elephant trunks for acute type A aortic dissection: Midterm results.
    Wada T; Yamamoto H; Takagi D; Kadohama T; Yamaura G; Kiryu K; Igarashi I
    JTCVS Tech; 2022 Aug; 14():29-38. PubMed ID: 35967231
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Concomitant true and false lumen "parallel thoracic endovascular aortic repair" as an endovascular alternative to open arch/descending aortic reconstruction for chronic DeBakey type I dissection with aneurysmal degeneration.
    Buddemeyer KM; Eudailey KW; Pearce BJ; Beck AW
    J Vasc Surg Cases Innov Tech; 2019 Dec; 5(4):557-560. PubMed ID: 31867472
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Remodeling of Aortic Configuration and Abdominal Aortic Branch Perfusion After Endovascular Repair of Acute Type B Aortic Dissection: A Computed Tomographic Angiography Follow-Up.
    Yuan Z; Li Y; Jin B; Wang J
    Front Cardiovasc Med; 2021; 8():752849. PubMed ID: 34760948
    [No Abstract]   [Full Text] [Related]  

  • 13. False lumen embolization as a rescue technique in the setting of acute and chronic dissecting aneurysms as adjunct to thoracic endovascular aortic repair.
    Rakestraw S; Feghali A; Nguyen K; Salvatore D; DiMuzio P; Abai B
    J Vasc Surg Cases Innov Tech; 2020 Mar; 6(1):110-117. PubMed ID: 32095669
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Systematic review of outcomes of combined proximal stent-grafting with distal bare stenting for management of aortic dissection.
    Canaud L; Faure EM; Ozdemir BA; Alric P; Thompson M
    Ann Cardiothorac Surg; 2014 May; 3(3):223-33. PubMed ID: 24967161
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Successful "PETTICOAT" procedure assisted by aortic angioscopy for complicated type B aortic dissection: Case report.
    Sakakibara S; Nishi H; Kitahara M; Goto T; Nakazato T
    Int J Surg Case Rep; 2023 Aug; 109():108475. PubMed ID: 37481972
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Successful Aortic Remodeling Through the Candy-Plug Technique for Chronic Type B Aortic Dissection.
    Shimizu H; Katayama K; Takata Y; Inoue R; Emura S; Takasaki T; Takahashi S
    Vasc Endovascular Surg; 2022 May; ():15385744221095921. PubMed ID: 35532352
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Simulation of thoracic endovascular aortic repair in a perfused patient-specific model of type B aortic dissection.
    Mohl L; Karl R; Hagedorn MN; Runz A; Skornitzke S; Toelle M; Bergt CS; Hatzl J; Uhl C; Böckler D; Meisenbacher K; Engelhardt S
    Int J Comput Assist Radiol Surg; 2024 Jun; ():. PubMed ID: 38848033
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Efficacy of Weflow Embedded Branch Stents in the Treatment of Stanford Type B Dissection Involving Left Subclavian Artery.
    Zhang M; Zhang J; Niu X; Wang Z; Zhang L
    Altern Ther Health Med; 2024 Apr; ():. PubMed ID: 38639623
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Stent-Graft Placement and Coil Embolization for Splenic Artery Aneurysm Derived from Isolated Spontaneous Celiac Artery Dissection.
    Hamada R; Yoshimatsu R; Yamanishi T; Matsumoto T; Osaki M; Yamagami T
    Ann Vasc Dis; 2023 Mar; 16(1):90-94. PubMed ID: 37006855
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Novel technique of entry to re-entry stent grafting enables not only to exclude false lumen but also to perfuse renal artery in patients with chronic Type B aortic dissection.
    Samura T; Fujimoto E; Hata H
    Eur Heart J Case Rep; 2023 Sep; 7(9):ytad408. PubMed ID: 37671249
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 4.