These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

170 related articles for article (PubMed ID: 36311232)

  • 1. Development of a computational fluid dynamic model to investigate the hemodynamic impact of REBOA.
    Renaldo AC; Lane MR; Shapiro SR; Mobin F; Jordan JE; Williams TK; Neff LP; Gayzik FS; Rahbar E
    Front Physiol; 2022; 13():1005073. PubMed ID: 36311232
    [No Abstract]   [Full Text] [Related]  

  • 2. Transition of Resuscitative Endovascular Balloon Occlusion of the Aorta from Zone 3 to Zone 1 to Treat Hemodynamic Collapse during Continued Hemorrhage.
    Rall JM; Baker KJ; Sandoval ML; Flinn AN; Causey MW
    Mil Med; 2024 Jan; 189(1-2):e285-e290. PubMed ID: 37552642
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Resuscitative endovascular balloon occlusion of the aorta for control of noncompressible truncal hemorrhage in the abdomen and pelvis.
    Moore LJ; Martin CD; Harvin JA; Wade CE; Holcomb JB
    Am J Surg; 2016 Dec; 212(6):1222-1230. PubMed ID: 28340927
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hemodynamic Effect of Resuscitative Endovascular Balloon Occlusion of the Aorta in Hemodynamic Instability Secondary to Acute Cardiac Tamponade in a Porcine Model.
    McGreevy DT; Björklund J; Nilsson KF; Hörer TM
    Shock; 2022 Feb; 57(2):291-297. PubMed ID: 34710883
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transition from abdominal aortic and junctional tourniquet to zone 3 resuscitative endovascular balloon occlusion of the aorta is feasible with hemodynamic support after porcine class IV hemorrhage.
    Brännström A; Dahlquist A; Gustavsson J; Arborelius UP; Günther M
    J Trauma Acute Care Surg; 2019 Oct; 87(4):849-855. PubMed ID: 31589194
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Abdominal aortic and junctional tourniquet versus zone III resuscitative endovascular balloon occlusion of the aorta in a swine junctional hemorrhage model.
    Schechtman DW; Kauvar DS; De Guzman R; Polykratis IA; Prince MD; Kheirabadi BS; Dubick MA
    J Trauma Acute Care Surg; 2020 Feb; 88(2):292-297. PubMed ID: 31999656
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Zone-dependent acute circulatory changes in abdominal organs and extremities after resuscitative balloon occlusion of the aorta (REBOA): an experimental model.
    Halvachizadeh S; Mica L; Kalbas Y; Lipiski M; Canic M; Teuben M; Cesarovic N; Rancic Z; Cinelli P; Neuhaus V; Pape HC; Pfeifer R
    Eur J Med Res; 2021 Jan; 26(1):10. PubMed ID: 33478582
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Endovascular variable aortic control (EVAC) versus resuscitative endovascular balloon occlusion of the aorta (REBOA) in a swine model of hemorrhage and ischemia reperfusion injury.
    Williams TK; Tibbits EM; Hoareau GL; Simon MA; Davidson AJ; DeSoucy ES; Faulconer ER; Grayson JK; Neff LP; Johnson MA
    J Trauma Acute Care Surg; 2018 Sep; 85(3):519-526. PubMed ID: 30142105
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The physiology of aortic flow and pressures during partial resuscitative endovascular balloon occlusion of the aorta in a swine model of hemorrhagic shock.
    Marble J; Patel NTP; Lane MR; Williams TK; Neff LP; Johnson MA
    J Trauma Acute Care Surg; 2022 Aug; 93(2S Suppl 1):S94-S101. PubMed ID: 35545802
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development of an Experimental and Digital Cardiovascular Arterial Model for Transient Hemodynamic and Postural Change Studies: "A Preliminary Framework Analysis".
    Hewlin RL; Kizito JP
    Cardiovasc Eng Technol; 2018 Mar; 9(1):1-31. PubMed ID: 29124548
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The effect of resuscitative endovascular balloon occlusion of the aorta, partial aortic occlusion and aggressive blood transfusion on traumatic brain injury in a swine multiple injuries model.
    Johnson MA; Williams TK; Ferencz SE; Davidson AJ; Russo RM; O'Brien WT; Galante JM; Grayson JK; Neff LP
    J Trauma Acute Care Surg; 2017 Jul; 83(1):61-70. PubMed ID: 28632582
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Resuscitative endovascular balloon occlusion of the aorta for thoracic trauma: A translational swine study.
    Glaser JJ; Neidert LE; Morgan CG; Brenner M; Stigall KS; Cardin S
    J Trauma Acute Care Surg; 2020 Sep; 89(3):474-481. PubMed ID: 32345903
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Defining degree of aortic occlusion for partial-REBOA: A computed tomography study on large animals.
    Reva VA; Matsumura Y; Samokhvalov IM; Pochtarnik AA; Zheleznyak IS; Mikhailovskaya EM; Morrison JJ
    Injury; 2018 Jun; 49(6):1058-1063. PubMed ID: 29699730
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Use of bilobed partial resuscitative endovascular balloon occlusion of the aorta is logistically superior in prolonged management of a highly lethal aortic injury.
    Zilberman-Rudenko J; Behrens B; McCully B; Dewey EN; Smith SG; Murphy JM; Goodman A; Underwood SJ; Rick EA; Madtson BM; Thompson ME; Glaser JJ; Holcomb JB; Schreiber MA
    J Trauma Acute Care Surg; 2020 Sep; 89(3):464-473. PubMed ID: 32467463
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Partial Resuscitative Endovascular Balloon Occlusion of the Aorta in Swine Model of Hemorrhagic Shock.
    Russo RM; Neff LP; Lamb CM; Cannon JW; Galante JM; Clement NF; Grayson JK; Williams TK
    J Am Coll Surg; 2016 Aug; 223(2):359-68. PubMed ID: 27138649
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Next-Generation REBOA (Resuscitative Endovascular Balloon Occlusion of the Aorta) Device Precisely Achieves Targeted Regional Optimization in a Porcine Model of Hemorrhagic Shock.
    Polcz JE; Ronaldi AE; Madurska M; Bedocs P; Leung LY; Burmeister DM; White PW; Rasmussen TE; White JM
    J Surg Res; 2022 Dec; 280():1-9. PubMed ID: 35939866
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Investigating the variability in pressure-volume relationships during hemorrhage and aortic occlusion.
    Mobin FU; Renaldo AC; Carrasco Perez E; Jordan JE; Neff LP; Williams TK; Johnson MA; Rahbar E
    Front Cardiovasc Med; 2023; 10():1171904. PubMed ID: 37680564
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A New Pressure-Regulated, Partial Resuscitative Endovascular Balloon Occlusion of the Aorta Device Achieves Targeted Distal Perfusion.
    White JM; Ronaldi AE; Polcz JE; Spreadborough P; Madurska M; Mares JA; Leung LY; Rasmussen TE
    J Surg Res; 2020 Dec; 256():171-179. PubMed ID: 32707400
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Aortic branch vessel flow during resuscitative endovascular balloon occlusion of the aorta.
    Hoehn MR; Teeter WA; Morrison JJ; Gamble WB; Hu P; Stein DM; Brenner ML; Scalea TM
    J Trauma Acute Care Surg; 2019 Jan; 86(1):79-85. PubMed ID: 30252777
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The AAST prospective Aortic Occlusion for Resuscitation in Trauma and Acute Care Surgery (AORTA) registry: Data on contemporary utilization and outcomes of aortic occlusion and resuscitative balloon occlusion of the aorta (REBOA).
    DuBose JJ; Scalea TM; Brenner M; Skiada D; Inaba K; Cannon J; Moore L; Holcomb J; Turay D; Arbabi CN; Kirkpatrick A; Xiao J; Skarupa D; Poulin N;
    J Trauma Acute Care Surg; 2016 Sep; 81(3):409-19. PubMed ID: 27050883
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.