  • 21. Three-dimensional full automated software in the evaluation of the left ventricle function: from theory to clinical practice.
    Barletta V; Hinojar R; Carbonell A; González-Gómez A; Fabiani I; Di Bello V; Jiménez-Nacher JJ; Zamorano J; Fernández-Golfín C
    Int J Cardiovasc Imaging; 2018 Aug; 34(8):1205-1213. PubMed ID: 29605902
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Left ventricular volume measurement with echocardiography: a comparison of left ventricular opacification, three-dimensional echocardiography, or both with magnetic resonance imaging.
    Jenkins C; Moir S; Chan J; Rakhit D; Haluska B; Marwick TH
    Eur Heart J; 2009 Jan; 30(1):98-106. PubMed ID: 18997179
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Machine learning based automated dynamic quantification of left heart chamber volumes.
    Narang A; Mor-Avi V; Prado A; Volpato V; Prater D; Tamborini G; Fusini L; Pepi M; Goyal N; Addetia K; Gonçalves A; Patel AR; Lang RM
    Eur Heart J Cardiovasc Imaging; 2019 May; 20(5):541-549. PubMed ID: 30304500
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Intervendor Consistency and Accuracy of Left Ventricular Volume Measurements Using Three-Dimensional Echocardiography.
    Muraru D; Cecchetto A; Cucchini U; Zhou X; Lang RM; Romeo G; Vannan M; Mihaila S; Miglioranza MH; Iliceto S; Badano LP
    J Am Soc Echocardiogr; 2018 Feb; 31(2):158-168.e1. PubMed ID: 29229493
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Association of outcome with left ventricular volumes and ejection fraction measured with two- and three-dimensional echocardiography in patients referred for routine, clinically indicated studies.
    Muraru D; Baldea SM; Genovese D; Tomaselli M; Heilbron F; Gavazzoni M; Radu N; Sergio C; Baratto C; Perelli F; Curti E; Parati G; Badano LP
    Front Cardiovasc Med; 2022; 9():1065131. PubMed ID: 36620642
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Use of three-dimensional speckle-tracking echocardiography for quantitative assessment of global left ventricular function: a comparative study to three-dimensional echocardiography.
    Luis SA; Yamada A; Khandheria BK; Speranza V; Benjamin A; Ischenko M; Platts DG; Hamilton-Craig CR; Haseler L; Burstow D; Chan J
    J Am Soc Echocardiogr; 2014 Mar; 27(3):285-91. PubMed ID: 24325960
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Imaging the heart failure patient-need for accurate measurements of left ventricular volumes and ejection fraction: the role of three-dimensional and contrast echocardiography.
    Gurunathan S; Karogiannis N; Senior R
    Curr Opin Cardiol; 2016 Sep; 31(5):459-68. PubMed ID: 27271926
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Feasibility, accuracy, and reproducibility of real-time full-volume 3D transthoracic echocardiography to measure LV volumes and systolic function: a fully automated endocardial contouring algorithm in sinus rhythm and atrial fibrillation.
    Thavendiranathan P; Liu S; Verhaert D; Calleja A; Nitinunu A; Van Houten T; De Michelis N; Simonetti O; Rajagopalan S; Ryan T; Vannan MA
    JACC Cardiovasc Imaging; 2012 Mar; 5(3):239-51. PubMed ID: 22421168
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography.
    Jenkins C; Bricknell K; Hanekom L; Marwick TH
    J Am Coll Cardiol; 2004 Aug; 44(4):878-86. PubMed ID: 15312875
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Diagnostic value of three-dimensional contrast-enhanced echocardiography for left ventricular volume and ejection fraction measurement in patients with poor acoustic windows: a comparison of echocardiography and magnetic resonance imaging.
    Saloux E; Labombarda F; Pellissier A; Anthune B; Dugué AE; Provost N; Allain P; De Craene M; Milliez P; Manrique A
    J Am Soc Echocardiogr; 2014 Oct; 27(10):1029-40. PubMed ID: 25063466
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Interinstitutional measurements of left ventricular volumes, speckle-tracking strain, and dyssynchrony using three-dimensional echocardiography.
    Tsang W; Kenny C; Adhya S; Kapetanakis S; Weinert L; Lang RM; Monaghan M
    J Am Soc Echocardiogr; 2013 Nov; 26(11):1253-7. PubMed ID: 24055125
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Quantitative assessment of left ventricular volume and ejection fraction using two-dimensional speckle tracking echocardiography.
    Nishikage T; Nakai H; Mor-Avi V; Lang RM; Salgo IS; Settlemier SH; Husson S; Takeuchi M
    Eur J Echocardiogr; 2009 Jan; 10(1):82-8. PubMed ID: 18490270
    [TBL] [Abstract][Full Text] [Related]  

  • 33. 3D echocardiographic global longitudinal strain can identify patients with mildly-to-moderately reduced ejection fraction at higher cardiovascular risk.
    Medvedofsky D; Lang RM; Weinert L; Tehrani DM; Narang A; Mor-Avi V
    Int J Cardiovasc Imaging; 2019 Sep; 35(9):1573-1579. PubMed ID: 30937684
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Two-year left ventricular systolic function of percutaneous coronary intervention vs optimal medical therapy for patients with single coronary chronic total occlusion.
    Meng S; Qiu L; Wu J; Huang R; Wang H
    Echocardiography; 2021 Feb; 38(2):368-373. PubMed ID: 33475185
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Three-dimensional echocardiographic measurements using automated quantification software for big data processing.
    Feng C; Chen L; Li J; Wang J; Dong F; Xu J
    J Xray Sci Technol; 2017; 25(2):313-321. PubMed ID: 28269820
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Reproducibility of echocardiographic techniques for sequential assessment of left ventricular ejection fraction and volumes: application to patients undergoing cancer chemotherapy.
    Thavendiranathan P; Grant AD; Negishi T; Plana JC; Popović ZB; Marwick TH
    J Am Coll Cardiol; 2013 Jan; 61(1):77-84. PubMed ID: 23199515
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Evaluation of the clinical suitability of automated left ventricle's fraction and volume measurements in 3-dimensional echocardiography compared to values obtained in magnetic resonance imaging (pilot study)].
    Żygadło A; Kaźnica-Wiatr M; Błaut-Jurkowska J; Knap K; Lenart-Migdalska A; Smaś-Suska M; Skubera M; Urbańczyk-Zawadzka M; Podolec P; Olszowska M
    Pol Merkur Lekarski; 2017 Oct; 43(256):154-157. PubMed ID: 29084187
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Feasibility and Accuracy of Automated Software for Transthoracic Three-Dimensional Left Ventricular Volume and Function Analysis: Comparisons with Two-Dimensional Echocardiography, Three-Dimensional Transthoracic Manual Method, and Cardiac Magnetic Resonance Imaging.
    Tamborini G; Piazzese C; Lang RM; Muratori M; Chiorino E; Mapelli M; Fusini L; Ali SG; Gripari P; Pontone G; Andreini D; Pepi M
    J Am Soc Echocardiogr; 2017 Nov; 30(11):1049-1058. PubMed ID: 28916243
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Contrast Enhancement and Image Quality Influence Two- and Three-dimensional Echocardiographic Determination of Left Ventricular Volumes: Comparison With Magnetic Resonance Imaging.
    Jenner J; Sörensson P; Pernow J; Caidahl K; Eriksson MJ
    Clin Med Insights Cardiol; 2019; 13():1179546819831980. PubMed ID: 30858745
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Performance of 3-dimensional echocardiography in measuring left ventricular volumes and ejection fraction: a systematic review and meta-analysis.
    Dorosz JL; Lezotte DC; Weitzenkamp DA; Allen LA; Salcedo EE
    J Am Coll Cardiol; 2012 May; 59(20):1799-808. PubMed ID: 22575319
    [TBL] [Abstract][Full Text] [Related]  