BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

112 related articles for article (PubMed ID: 3631697)

  • 1. Technique for repeated collection of blood that has just perfused the pineal gland of sheep.
    Colombo G; Cozzi B; Cremonesi F; Reiter RJ
    Am J Vet Res; 1987 Jul; 48(7):1126-8. PubMed ID: 3631697
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A non-surgical jugular catheterization technique for multiple blood sampling in cats.
    Albarellos GA; Bonafine RR; Kreil VE; Ambros LA; Montoya L; Hallu RE
    Lab Anim; 2003 Jul; 37(3):188-92. PubMed ID: 12869280
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Non-surgical alternatives to invasive procedures in mice.
    Marini JC; Lee B; Garlick PJ
    Lab Anim; 2006 Jul; 40(3):275-81. PubMed ID: 16803644
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Percutaneous, ultrasonographically guided technique of catheterization of the abdominal aorta in calves for serial blood sampling and continuous arterial blood pressure measurement.
    Offinger J; Fischer J; Rehage J; Meyer H
    Res Vet Sci; 2011 Jun; 90(3):521-5. PubMed ID: 20727559
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Technique for chronic cannulation of the dorsal sagittal sinus of cattle.
    James VC; Himes RW; Purhoit RC; Raju KG
    Am J Vet Res; 1970 Aug; 31(8):1489-91. PubMed ID: 5449903
    [No Abstract]   [Full Text] [Related]  

  • 6. Long-term blood access by catheters implanted into arteriovenous fistulas of sheep.
    Dennis MB; Cole JJ; Jensen WM; Scribner BH
    Lab Anim Sci; 1984 Aug; 34(4):388-92. PubMed ID: 6482380
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A simple technic for repeated collection of blood samples from mice.
    Stoltz DR; Bendall RD
    Lab Anim Sci; 1975 Jun; 25(3):353-4. PubMed ID: 1142733
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dual cannulation: a method for continuous intravenous infusion and repeated blood sampling in unrestrained mice.
    Hodge DE; Shalev M
    Lab Anim Sci; 1992 Jun; 42(3):320-22. PubMed ID: 1320170
    [No Abstract]   [Full Text] [Related]  

  • 9. Atrial cannulation for long-term sequential blood collection in gilts.
    Kemp C; Kruger JS
    Am J Vet Res; 1987 Jun; 48(6):990-1. PubMed ID: 3605816
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cannulation of renal veins of sheep for long-term functional and metabolic studies.
    Kaufman CF; Bergman EN
    Am J Vet Res; 1971 Jul; 32(7):1103-7. PubMed ID: 5089197
    [No Abstract]   [Full Text] [Related]  

  • 11. Cannulation of the jugular vein in mice: a method for serial withdrawal of blood samples.
    Bardelmeijer HA; Buckle T; Ouwehand M; Beijnen JH; Schellens JH; van Tellingen O
    Lab Anim; 2003 Jul; 37(3):181-7. PubMed ID: 12869279
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Intravenous indwelling catheter in the sow].
    Walzl H; Mayer P
    Berl Munch Tierarztl Wochenschr; 1977 Feb; 90(3):57-9. PubMed ID: 836706
    [No Abstract]   [Full Text] [Related]  

  • 13. [Procedure for continuous subpartal blood specimen collection in the calf].
    Waizenhöfer H; Brattig B
    Berl Munch Tierarztl Wochenschr; 1975 Jun; 88(11):204-5. PubMed ID: 1200958
    [No Abstract]   [Full Text] [Related]  

  • 14. An exteriorized cranial vena caval catheter for serial blood sample collection from miniature swine.
    Wingfield WE; Tumbleson ME; Hicklin KW; Mather EC
    Lab Anim Sci; 1974 Apr; 24(2):359-61. PubMed ID: 4362887
    [No Abstract]   [Full Text] [Related]  

  • 15. [A frequent problem in the laboratory control of heparinization: contamination of blood specimens with exogenous heparin].
    Lämmle B; Noll G; Häuptli W; Tran TH; Luengo E; Lohri A; Ritz R; Duckert F
    Schweiz Med Wochenschr; 1984 Jun; 114(24):873-5. PubMed ID: 6740303
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A simple venous catheter for sequential blood sampling from unrestrained pigs.
    Christison GI; Curtin TM
    Lab Anim Care; 1969 Apr; 19(2):259-62. PubMed ID: 4240239
    [No Abstract]   [Full Text] [Related]  

  • 17. Chronic subcutaneous implantation of a blood vessel catheter injection cap.
    Klide AM
    Am J Vet Res; 1975 Feb; 36(2):237-8. PubMed ID: 1111391
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Protecting short-term intravascular ear catheters in healthy rabbits.
    Sampieri F; Orchard RN; Antonopoulos AJ; Hamilton DL
    Lab Anim (NY); 2012 Jan; 41(2):44-8. PubMed ID: 22261889
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Long-term cranial mesenteric vein cannulation in the rat.
    Zammit M; Toledo-Pereyra LH; Malcom S; Konde WN
    Lab Anim Sci; 1979 Jun; 29(3):364-6. PubMed ID: 502463
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A rapid method for repeated collection of blood from the tail vein of rats.
    Stearns SM; Lee PW
    Lab Anim Sci; 1984 Aug; 34(4):395-6. PubMed ID: 6482382
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.