BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

238 related articles for article (PubMed ID: 36318313)

  • 21. Analytical and clinical validation of dried blood spot and volumetric absorptive microsampling for measurement of tacrolimus and creatinine after renal transplantation.
    Mathew BS; Mathew SK; Aruldhas BW; Prabha R; Gangadharan N; David VG; Varughese S; John GT
    Clin Biochem; 2022; 105-106():25-34. PubMed ID: 35490728
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Volumetric absorptive microsampling (VAMS®) in therapeutic protein quantification by LC-MS/MS: Investigation of anticoagulant impact on assay performance and recommendations for best practices in method development.
    Gao X; Chen C; Geng D; Bateman KP; Shi S; Woolf EJ; Xu Y
    J Pharm Biomed Anal; 2021 Mar; 196():113895. PubMed ID: 33486450
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Blood and Plasma Volumetric Absorptive Microsampling (VAMS) Coupled to LC-MS/MS for the Forensic Assessment of Cocaine Consumption.
    Mandrioli R; Mercolini L; Protti M
    Molecules; 2020 Feb; 25(5):. PubMed ID: 32110941
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Capillary blood collected on volumetric absorptive microsampling (VAMS) device for monitoring hydroxychloroquine in rheumatoid arthritis patients.
    Qu Y; Brady K; Apilado R; O'Malley T; Reddy S; Chitkara P; Ibarra C; Alexander RV; Dervieux T
    J Pharm Biomed Anal; 2017 Jun; 140():334-341. PubMed ID: 28391006
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Validation of LC-MS/MS method for determination of rosuvastatin concentration in human blood collected by volumetric absorptive microsampling (VAMS).
    Moon SJ; Lee SE; Kwak YG; Kim MG
    Transl Clin Pharmacol; 2021 Sep; 29(3):125-134. PubMed ID: 34621705
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Pre-analytic evaluation of volumetric absorptive microsampling and integration in a mass spectrometry-based metabolomics workflow.
    Volani C; Caprioli G; Calderisi G; Sigurdsson BB; Rainer J; Gentilini I; Hicks AA; Pramstaller PP; Weiss G; Smarason SV; Paglia G
    Anal Bioanal Chem; 2017 Oct; 409(26):6263-6276. PubMed ID: 28815270
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Hepcidin determination in dried blood by microfluidic LC-MS/MS: comparison of DBS and volumetric absorptive microsampling for matrix effect and recovery.
    Houbart V; Cobraiville G; Servais AC; Napp A; Merville MP; Fillet M
    Bioanalysis; 2015 Nov; 7(21):2789-99. PubMed ID: 26595680
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Automation of tacrolimus measurement on volumetric absorptive microsampling devices by tandem mass spectrometry.
    Carling RS; John C; Emmett EC; Austin D; Hastie C; Liscio C
    Bioanalysis; 2022 Dec; 14(23):1487-1496. PubMed ID: 36705023
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Extractability-mediated stability bias and hematocrit impact: High extraction recovery is critical to feasibility of volumetric adsorptive microsampling (VAMS) in regulated bioanalysis.
    Xie I; Xu Y; Anderson M; Wang M; Xue L; Breidinger S; Goykhman D; Woolf EJ; Bateman KP
    J Pharm Biomed Anal; 2018 Jul; 156():58-66. PubMed ID: 29689469
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Volumetric absorptive MicroSampling vs. other blood sampling materials in LC-MS-based protein analysis - preliminary investigations.
    Andersen IKL; Rosting C; Gjelstad A; Halvorsen TG
    J Pharm Biomed Anal; 2018 Jul; 156():239-246. PubMed ID: 29729637
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Measurement of 5- fluorouracil, capecitabine and its metabolite concentrations in blood using volumetric absorptive microsampling technology and LC-MS/MS.
    Radovanovic M; Schneider JJ; Shafiei M; Martin JH; Galettis P
    J Chromatogr B Analyt Technol Biomed Life Sci; 2022 Jan; 1188():123075. PubMed ID: 34891049
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Simultaneous determination of vancomycin and creatinine in plasma applied to volumetric absorptive microsampling devices using liquid chromatography-tandem mass spectrometry.
    Andriguetti NB; Lisboa LL; Hahn SR; Pagnussat LR; Antunes MV; Linden R
    J Pharm Biomed Anal; 2019 Feb; 165():315-324. PubMed ID: 30579232
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Therapeutic drug monitoring of mycophenolic acid (MPA) using volumetric absorptive microsampling (VAMS) in pediatric renal transplant recipients: ultra-high-performance liquid chromatography-tandem mass spectrometry analytical method development, cross-validation, and clinical application.
    Kocur A; Rubik J; Czarnowski P; Czajkowska A; Marszałek D; Sierakowski M; Górska M; Pawiński T
    Pharmacol Rep; 2023 Aug; 75(4):1026-1042. PubMed ID: 37452967
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Fingerprick volumetric absorptive microsampling for therapeutic drug monitoring of antiseizure medications: Reliability and real-life feasibility in epilepsy patients.
    Cancellerini C; Belotti LMB; Mohamed S; Solda' M; Esposito E; Bisulli F; Mostacci B; Vignatelli L; Tinuper P; Contin M; Licchetta L;
    J Pharm Biomed Anal; 2024 May; 242():116065. PubMed ID: 38401349
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Towards clinical adherence monitoring of oral endocrine breast cancer therapies by LC-HRMS-method development, validation, comparison of four sample matrices, and proof of concept.
    Jacobs CM; Radosa JC; Wagmann L; Zimmermann JSM; Kaya AC; Aygün A; Edel T; Stotz L; Ismaeil M; Solomayer EF; Meyer MR
    Anal Bioanal Chem; 2024 May; 416(12):2969-2981. PubMed ID: 38488952
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Quantitative bioanalysis of paracetamol in rats using volumetric absorptive microsampling (VAMS).
    Denniff P; Parry S; Dopson W; Spooner N
    J Pharm Biomed Anal; 2015 Apr; 108():61-9. PubMed ID: 25710904
    [TBL] [Abstract][Full Text] [Related]  

  • 37. LC-MS/MS and volumetric absorptive microsampling for quantitative bioanalysis of cathinone analogues in dried urine, plasma and oral fluid samples.
    Mercolini L; Protti M; Catapano MC; Rudge J; Sberna AE
    J Pharm Biomed Anal; 2016 May; 123():186-94. PubMed ID: 26905673
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Mercury biomonitoring in German adults using volumetric absorptive microsampling.
    Koutsimpani-Wagner A; Quartucci C; Rooney JPK; Bose-O'Reilly S; Rakete S
    Environ Monit Assess; 2022 Mar; 194(4):315. PubMed ID: 35355133
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Drug monitoring by volumetric absorptive microsampling: method development considerations to mitigate hematocrit effects.
    Fang K; Bowen CL; Kellie JF; Karlinsey MZ; Evans CA
    Bioanalysis; 2018 Feb; 10(4):241-255. PubMed ID: 29333871
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Development and validation of a bioanalytical method for the quantification of methotrexate from serum and capillary blood using volumetric absorptive microsampling (VAMS) and on-line solid phase extraction (SPE) LC-MS.
    Opitz P; Fobker M; Fabian J; Hempel G
    J Chromatogr A; 2024 Jan; 1715():464610. PubMed ID: 38157584
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.