These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 36319381)

  • 1. Development of an x-ray radiography platform to study laser-direct-drive energy coupling at the National Ignition Facility.
    Ceurvorst L; Theobald W; Rosenberg MJ; Radha PB; Stoeckl C; Betti R; Anderson KS; Marozas JA; Goncharov VN; Campbell EM; Shuldberg CM; Luo RW; Sweet W; Aghaian L; Carlson L; Bachmann B; Döppner T; Hohenberger M; Glize K; Scott RHH; Colaïtis A; Regan SP
    Rev Sci Instrum; 2022 Oct; 93(10):105102. PubMed ID: 36319381
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The Crystal Backlighter Imager: A spherically bent crystal imager for radiography on the National Ignition Facility.
    Hall GN; Krauland CM; Schollmeier MS; Kemp GE; Buscho JG; Hibbard R; Thompson N; Casco ER; Ayers MJ; Ayers SL; Meezan NB; Hopkins LFB; Nora R; Hammel BA; Masse L; Field JE; Bradley DK; Bell P; Landen OL; Kilkenny JD; Mariscal D; Park J; McCarville TJ; Lowe-Webb R; Kalantar D; Kohut T; Piston K
    Rev Sci Instrum; 2019 Jan; 90(1):013702. PubMed ID: 30709218
    [TBL] [Abstract][Full Text] [Related]  

  • 3. High resolution >40 keV x-ray radiography using an edge-on micro-flag backlighter at NIF-ARC.
    Hill MP; Williams GJ; Zylstra AB; Stan CV; Lockard TE; Gumbrell ET; Rudd RE; Powell PD; Swift DC; McNaney JM; Le Galloudec KK; Remington BA; Park HS
    Rev Sci Instrum; 2021 Mar; 92(3):033535. PubMed ID: 33820053
    [TBL] [Abstract][Full Text] [Related]  

  • 4. X-ray imaging of Rayleigh-Taylor instabilities using Fresnel zone plate at the National Ignition Facility.
    Do A; Angulo AM; Hall GN; Nagel SR; Izumi N; Kozioziemski BJ; McCarville T; Ayers JM; Bradley DK
    Rev Sci Instrum; 2021 May; 92(5):053511. PubMed ID: 34243355
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development of a Big Area BackLighter for high energy density experiments.
    Flippo KA; Kline JL; Doss FW; Loomis EN; Emerich M; Devolder B; Murphy TJ; Fournier KB; Kalantar DH; Regan SP; Barrios MA; Merritt EC; Perry TS; Tregillis IL; Welser-Sherrill L; Fincke JR
    Rev Sci Instrum; 2014 Sep; 85(9):093501. PubMed ID: 25273720
    [TBL] [Abstract][Full Text] [Related]  

  • 6. AXIS: an instrument for imaging Compton radiographs using the Advanced Radiography Capability on the NIF.
    Hall GN; Izumi N; Tommasini R; Carpenter AC; Palmer NE; Zacharias R; Felker B; Holder JP; Allen FV; Bell PM; Bradley D; Montesanti R; Landen OL
    Rev Sci Instrum; 2014 Nov; 85(11):11D624. PubMed ID: 25430200
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Diagnosing radiative shocks from deuterium and tritium implosions on NIF.
    Pak A; Divol L; Weber S; Döppner T; Kyrala GA; Kilne J; Izumi N; Glenn S; Ma T; Town RP; Bradley DK; Glenzer SH
    Rev Sci Instrum; 2012 Oct; 83(10):10E507. PubMed ID: 23127014
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Using penumbral imaging to measure micrometer size plasma hot spots in Gbar equation of state experiments on the National Ignition Facility.
    Bachmann B; Kritcher AL; Benedetti LR; Falcone RW; Glenn S; Hawreliak J; Izumi N; Kraus D; Landen OL; Le Pape S; Ma T; Pérez F; Swift D; Döppner T
    Rev Sci Instrum; 2014 Nov; 85(11):11D614. PubMed ID: 25430190
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Investigating high speed phenomena in laser plasma interactions using dilation x-ray imager (invited).
    Nagel SR; Hilsabeck TJ; Bell PM; Bradley DK; Ayers MJ; Piston K; Felker B; Kilkenny JD; Chung T; Sammuli B; Hares JD; Dymoke-Bradshaw AK
    Rev Sci Instrum; 2014 Nov; 85(11):11E504. PubMed ID: 25430346
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A high-speed two-frame, 1-2 ns gated X-ray CMOS imager used as a hohlraum diagnostic on the National Ignition Facility (invited).
    Chen H; Palmer N; Dayton M; Carpenter A; Schneider MB; Bell PM; Bradley DK; Claus LD; Fang L; Hilsabeck T; Hohenberger M; Jones OS; Kilkenny JD; Kimmel MW; Robertson G; Rochau G; Sanchez MO; Stahoviak JW; Trotter DC; Porter JL
    Rev Sci Instrum; 2016 Nov; 87(11):11E203. PubMed ID: 27910306
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Absolute Hugoniot measurements from a spherically convergent shock using x-ray radiography.
    Swift DC; Kritcher AL; Hawreliak JA; Lazicki A; MacPhee A; Bachmann B; Döppner T; Nilsen J; Collins GW; Glenzer S; Rothman SD; Kraus D; Falcone RW
    Rev Sci Instrum; 2018 May; 89(5):053505. PubMed ID: 29864815
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Soft x-ray backlighting of direct-drive implosions using a spherical crystal imager on OMEGA.
    Stoeckl C; Delettrez JA; Epstein R; Fiksel G; Guy D; Hohenberger M; Jungquist RK; Mileham C; Nilson PM; Sangster TC; Shoup MJ; Theobald W
    Rev Sci Instrum; 2012 Oct; 83(10):10E501. PubMed ID: 23127008
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Bremsstrahlung x-ray generation for high optical depth radiography applications on the National Ignition Facility.
    Huntington CM; McNaney JM; Gumbrell E; Krygier A; Wehrenberg C; Park HS
    Rev Sci Instrum; 2018 Oct; 89(10):10G121. PubMed ID: 30399794
    [TBL] [Abstract][Full Text] [Related]  

  • 14. X-ray area backlighter development at the National Ignition Facility (invited).
    Barrios MA; Regan SP; Fournier KB; Epstein R; Smith R; Lazicki A; Rygg R; Fratanduono DE; Eggert J; Park HS; Huntington C; Bradley DK; Landen OL; Collins GW
    Rev Sci Instrum; 2014 Nov; 85(11):11D502. PubMed ID: 25430176
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Characterization of a 1D-imaging high-energy x-ray backlighter driven by the National Ignition Facility Advanced Radiographic Capability laser.
    Hill MP; Williams GJ; Kalantar DH; Bachmann B; Martinez DA; Stan CV; Murphy A; Arend MJ; Mercado GA; Wong HC; Dunn Z; Santos CD; Lockard TE; Gumbrell ET; Rudd RE; McNaney JM; Le Galloudec KK; Remington BA; Park HS
    Rev Sci Instrum; 2022 Oct; 93(10):103506. PubMed ID: 36319395
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Hot-electron preheat and mitigation in polar-direct-drive experiments at the National Ignition Facility.
    Solodov AA; Rosenberg MJ; Stoeckl M; Christopherson AR; Betti R; Radha PB; Stoeckl C; Hohenberger M; Bachmann B; Epstein R; Follett RK; Seka W; Myatt JF; Michel P; Regan SP; Palastro JP; Froula DH; Campbell EM; Goncharov VN
    Phys Rev E; 2022 Nov; 106(5-2):055204. PubMed ID: 36559374
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A 7.2 keV spherical x-ray crystal backlighter for two-frame, two-color backlighting at Sandia's Z Pulsed Power Facility.
    Schollmeier MS; Knapp PF; Ampleford DJ; Harding EC; Jennings CA; Lamppa DC; Loisel GP; Martin MR; Robertson GK; Shores JE; Smith IC; Speas CS; Weis MR; Porter JL; McBride RD
    Rev Sci Instrum; 2017 Oct; 88(10):103503. PubMed ID: 29092482
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fresnel zone plate development for x-ray radiography of hydrodynamic instabilities at the National Ignition Facility.
    Do A; Pickworth LA; Kozioziemski BJ; Angulo AM; Hall GN; Nagel SR; Bradley DK; Mccarville T; Ayers JM
    Appl Opt; 2020 Dec; 59(34):10777-10785. PubMed ID: 33361898
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Absolute calibration of a time-resolved high resolution x-ray spectrometer for the National Ignition Facility (invited).
    Gao L; Kraus BF; Hill KW; Bitter M; Efthimion P; Schneider MB; MacPhee AG; Thorn DB; Kilkenny J; Ayers J; Kauffman R; Chen H; Nelson D
    Rev Sci Instrum; 2018 Oct; 89(10):10F125. PubMed ID: 30399848
    [TBL] [Abstract][Full Text] [Related]  

  • 20. NIF-scale re-emission sphere measurements of early-time Tr = 100 eV hohlraum symmetry (invited).
    Dewald EL; Thomas C; Milovich J; Edwards J; Sorce C; Kirkwood R; Meeker D; Jones O; Izumi N; Landen OL
    Rev Sci Instrum; 2008 Oct; 79(10):10E903. PubMed ID: 19044558
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.