These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 3632730)

  • 1. Needle enzyme electrodes for biological studies.
    Churchouse SJ; Battersby CM; Mullen WH; Vadgama PM
    Biosensors; 1986; 2(6):325-42. PubMed ID: 3632730
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The glucose enzyme electrode: is simple peroxide detection at a needle sensor acceptable?
    Vadgama P; Mullen W; Churchouse S; Battersby C
    Horm Metab Res Suppl; 1988; 20():20-2. PubMed ID: 3248785
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The needle glucose electrode: in vitro performance and optimisation for implantation.
    Vadgama P; Spoors J; Tang LX; Battersby C
    Biomed Biochim Acta; 1989; 48(11-12):935-42. PubMed ID: 2636838
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Lactate and pyruvate electrochemical biosensors for whole blood in extracorporeal experiments with an endocrine artificial pancreas.
    Mascini M; Mazzei F; Moscone D; Calabrese G; Benedetti MM
    Clin Chem; 1987 Apr; 33(4):591-3. PubMed ID: 3829396
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An O2-based enzyme electrode for whole blood lactate measurement under continuous flow conditions.
    Weaver MR; Vadgama PM
    Clin Chim Acta; 1986 Mar; 155(3):295-307. PubMed ID: 3708858
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Long-functioning beta-D-glucose and L-lactate biosensors for continuous flow-through measurements for "fouling"-resistant and selectivity-optimized serum- and hemoanalysis].
    Schindler JG; Schindler MM; Herna K; Pohl M; Guntermann H; Burk B; Reisinger E
    Eur J Clin Chem Clin Biochem; 1994 Aug; 32(8):599-608. PubMed ID: 7819432
    [TBL] [Abstract][Full Text] [Related]  

  • 7. "Wired" enzyme electrodes for amperometric determination of glucose or lactate in the presence of interfering substances.
    Ohara TJ; Rajagopalan R; Heller A
    Anal Chem; 1994 Aug; 66(15):2451-7. PubMed ID: 8092486
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Glucose and lactate biosensors prepared by a layer-by-layer deposition of concanavalin A and mannose-labeled enzymes: electrochemical response in the presence of electron mediators.
    Kobayashi Y; Hoshi T; Anzai J
    Chem Pharm Bull (Tokyo); 2001 Jun; 49(6):755-7. PubMed ID: 11411531
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Silicon/SU8 multi-electrode micro-needle for in vivo neurochemical monitoring.
    Vasylieva N; Marinesco S; Barbier D; Sabac A
    Biosens Bioelectron; 2015 Oct; 72():148-55. PubMed ID: 25978443
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fabrication of an implantable fine needle-type glucose sensor using gamma-polyglutamic acid.
    Takaoka H; Yasuzawa M
    Anal Sci; 2010; 26(5):551-5. PubMed ID: 20467129
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Enzyme electrode for the measurement of lactate in undiluted blood.
    Mullen WH; Churchouse SJ; Keedy FH; Vadgama PM
    Clin Chim Acta; 1986 Jun; 157(2):191-8. PubMed ID: 3719998
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Glucose enzyme electrode with percutaneous interface which operates independently of dissolved oxygen.
    Kusano H
    Clin Phys Physiol Meas; 1989 Feb; 10(1):1-9. PubMed ID: 2714056
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A potentially implantable enzyme electrode for amperometric measurement of glucose.
    Kerner W; Zier H; Steinbach G; Brückel J; Pfeiffer EF; Weiss T; Cammann K; Planck H
    Horm Metab Res Suppl; 1988; 20():8-13. PubMed ID: 3248792
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A comparison between different immobilised glucoseoxidase-based electrodes.
    Memoli A; Annesini MC; Mascini M; Papale S; Petralito S
    J Pharm Biomed Anal; 2002 Aug; 29(6):1045-52. PubMed ID: 12110389
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Highly selective needle-type glucose sensors prepared by the immobilization of glucose oxidase on γ-polyglutamic acid film.
    Yasuzawa M; Edagawa K; Matsunaga T; Takaoka H; Yabutani T
    Anal Sci; 2011; 27(3):337-40. PubMed ID: 21415521
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Enzyme electrodes as practical biosensors.
    Vadgama P
    J Med Eng Technol; 1981 Nov; 5(6):293-8. PubMed ID: 7035672
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Enzyme electrode for determining glucose in whole blood.
    Genshaw MA
    Clin Chem; 1988 Sep; 34(9):1717-9. PubMed ID: 3416421
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Polymeric FAD used as enzyme-friendly mediator in lactate detection.
    Leonida MD; Starczynowski DT; Waldman R; Aurian-Blajeni B
    Anal Bioanal Chem; 2003 Jul; 376(6):832-7. PubMed ID: 12811450
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A fine pointed glucose oxidase immobilized electrode for low-invasive amperometric glucose monitoring.
    Li J; Koinkar P; Fuchiwaki Y; Yasuzawa M
    Biosens Bioelectron; 2016 Dec; 86():90-94. PubMed ID: 27336616
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A needle-type sensor for monitoring glucose in whole blood.
    Yang Q; Atanasov P; Wilkins E
    Biomed Instrum Technol; 1997; 31(1):54-62. PubMed ID: 9051226
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.