BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 36327608)

  • 1. Dosimetric verification of cancer patient's treatment plan using an anthropomorphic, 3D-printed phantom.
    Waluk K; Pietrzak J
    Appl Radiat Isot; 2023 Jan; 191():110490. PubMed ID: 36327608
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A customizable anthropomorphic phantom for dosimetric verification of 3D-printed lung, tissue, and bone density materials.
    Tino RB; Yeo AU; Brandt M; Leary M; Kron T
    Med Phys; 2022 Jan; 49(1):52-69. PubMed ID: 34796527
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Characterization of a novel 3D printed patient specific phantom for quality assurance in cranial stereotactic radiosurgery applications.
    Makris DN; Pappas EP; Zoros E; Papanikolaou N; Saenz DL; Kalaitzakis G; Zourari K; Efstathopoulos E; Maris TG; Pappas E
    Phys Med Biol; 2019 May; 64(10):105009. PubMed ID: 30965289
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development and validation of a 3D-printed bolus cap for total scalp irradiation.
    Baltz GC; Chi PM; Wong PF; Wang C; Craft DF; Kry SF; Lin SSH; Garden AS; Smith SA; Howell RM
    J Appl Clin Med Phys; 2019 Mar; 20(3):89-96. PubMed ID: 30821903
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification.
    McDermott LN; Wendling M; van Asselen B; Stroom J; Sonke JJ; van Herk M; Mijnheer BJ
    Med Phys; 2006 Oct; 33(10):3921-30. PubMed ID: 17089854
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dosimetric performance of the Elekta Unity MR-linac system: 2D and 3D dosimetry in anthropomorphic inhomogeneous geometry.
    Pappas E; Kalaitzakis G; Boursianis T; Zoros E; Zourari K; Pappas EP; Makris D; Seimenis I; Efstathopoulos E; Maris TG
    Phys Med Biol; 2019 Nov; 64(22):225009. PubMed ID: 31665709
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Patient specific 3D printed phantom for IMRT quality assurance.
    Ehler ED; Barney BM; Higgins PD; Dusenbery KE
    Phys Med Biol; 2014 Oct; 59(19):5763-73. PubMed ID: 25207965
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Characterizing 3D printing in the fabrication of variable density phantoms for quality assurance of radiotherapy.
    Madamesila J; McGeachy P; Villarreal Barajas JE; Khan R
    Phys Med; 2016 Jan; 32(1):242-7. PubMed ID: 26508016
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Application of 3D-print silica bolus for nasal NK/T-cell lymphoma radiation therapy.
    Dai G; Xu X; Wu X; Lei X; Wei X; Li Z; Xiao Q; Zhong R; Bai S
    J Radiat Res; 2020 Nov; 61(6):920-928. PubMed ID: 32960262
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Technical note: Commissioning of a low-cost system for directly 3D printed flexible bolus.
    Baltz GC; Kirsner SM
    J Appl Clin Med Phys; 2023 Dec; 24(12):e14206. PubMed ID: 37962024
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dosimetric verification of IMPT using a commercial heterogeneous phantom.
    Yasui K; Toshito T; Omachi C; Hayashi K; Kinou H; Katsurada M; Hayashi N; Ogino H
    J Appl Clin Med Phys; 2019 Feb; 20(2):114-120. PubMed ID: 30673145
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characterization of 3D-printed bolus produced at different printing parameters.
    Biltekin F; Yazici G; Ozyigit G
    Med Dosim; 2021 Summer; 46(2):157-163. PubMed ID: 33172711
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development and dosimetric verification of 3D customized bolus in head and neck radiotherapy.
    Chatchumnan N; Kingkaew S; Aumnate C; Sanghangthum T
    J Radiat Res; 2022 May; 63(3):428-434. PubMed ID: 35420693
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Personalized 3D-printed anthropomorphic phantoms for dosimetry in charged particle fields.
    Halloran A; Newhauser W; Chu C; Donahue W
    Phys Med Biol; 2021 Nov; 66(22):. PubMed ID: 34654002
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of a 3D printing process of bolus using BolusCM material for radiotherapy with electrons.
    Diaz-Merchan JA; Martinez-Ovalle SA; Vega-Carrillo HR
    Appl Radiat Isot; 2023 Sep; 199():110899. PubMed ID: 37321051
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Preclinical dose verification using a 3D printed mouse phantom for radiobiology experiments.
    Esplen N; Therriault-Proulx F; Beaulieu L; Bazalova-Carter M
    Med Phys; 2019 Nov; 46(11):5294-5303. PubMed ID: 31461781
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparing the accuracy of four-dimensional photon dose calculations with three-dimensional calculations using moving and deforming phantoms.
    Vinogradskiy YY; Balter P; Followill DS; Alvarez PE; White RA; Starkschall G
    Med Phys; 2009 Nov; 36(11):5000-6. PubMed ID: 19994509
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Technical Note: Manufacturing of a realistic mouse phantom for dosimetry of radiobiology experiments.
    Esplen N; Alyaqoub E; Bazalova-Carter M
    Med Phys; 2019 Feb; 46(2):1030-1036. PubMed ID: 30488962
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A motorized solid-state phantom for patient-specific dose verification in ion beam radiotherapy.
    Henkner K; Winter M; Echner G; Ackermann B; Brons S; Horn J; Jäkel O; Karger CP
    Phys Med Biol; 2015 Sep; 60(18):7151-63. PubMed ID: 26334387
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A customized bolus produced using a 3-dimensional printer for radiotherapy.
    Kim SW; Shin HJ; Kay CS; Son SH
    PLoS One; 2014; 9(10):e110746. PubMed ID: 25337700
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.